Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens

被引:56
|
作者
Tang, YW
Sefers, SE
Li, HJ
Kohn, DJ
Procop, GW
机构
[1] Vanderbilt Univ, Sch Med, Dept Med, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Sch Med, Dept Pathol, Nashville, TN 37232 USA
[3] Cleveland Clin Fdn, Clin Microbiol Sect, Cleveland, OH 44195 USA
关键词
D O I
10.1128/JCM.43.9.4830-4833.2005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.
引用
收藏
页码:4830 / 4833
页数:4
相关论文
共 50 条
  • [31] Comparison of two nucleic acid extraction and testing systems for HCMV-DNA detection and quantitation on whole blood specimens from transplant patients
    Costa, Cristina
    Mantovani, Samantha
    Balloco, Cinzia
    Sidoti, Francesca
    Fop, Fabrizio
    Cavallo, Rossana
    JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (02) : 579 - 582
  • [32] Extraction of nucleic acid fragments from gels
    Kurien, BT
    Scofield, RH
    ANALYTICAL BIOCHEMISTRY, 2002, 302 (01) : 1 - 9
  • [33] Nucleic acid extraction from biomining microorganisms
    Zammit, C. M.
    Mutch, L. A.
    Watling, H. R.
    Watkin, E. L. J.
    BIOHYDROMETALLURGY: A MEETING POINT BETWEEN MICROBIAL ECOLOGY, METAL RECOVERY PROCESSES AND ENVIRONMENTAL REMEDIATION, 2009, 71-73 : 159 - +
  • [34] Extraction of Nucleic Acids Comparison of automated and manual Extraction Methods from nucleic acid-based Detection Systems in the Food Laboratory
    Lorenzen, Erika
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 2020, 116 (07) : 292 - 295
  • [35] Regeneration of commercial nucleic acid extraction columns without the risk of carryover contamination
    Siddappa, Nagadenahalli B.
    Avinash, Appukuttan
    Venkatramanan, Mohanram
    Ranga, Udaykumar
    BIOTECHNIQUES, 2007, 42 (02) : 184 - +
  • [36] Viability of Mycobacterium tuberculosis after Processing with Commercial Nucleic Acid Extraction Kits
    Clinghan, Richard
    Anderson, Trevor P.
    Everett, Valerie
    Murdoch, David R.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (06) : 2010 - 2010
  • [37] Comparative Analysis of Three Different Total Nucleic Acid Extraction Protocols for the Diagnosis of Geminiviruses in Squash (Cucurbita moschata)
    Hernandez, Eduardo J.
    Mora-Umana, Floribeth
    Albertazzi, Federico
    Karkashian, James P.
    Ramirez, Pilar
    JOURNAL OF PHYTOPATHOLOGY, 2012, 160 (01) : 19 - 25
  • [38] Evaluation of three commercial molecular amplification systems to detect Chlamydia trachomatis nucleic acids in synovial fluid.
    Wollenhaupt, J
    Kuipers, JG
    Andresen, J
    Köhler, L
    Zeidler, H
    ARTHRITIS AND RHEUMATISM, 1998, 41 (09): : S149 - S149
  • [39] Evaluation of the new NucliSens easyMAG® nucleic acid extraction system
    Bossart, W.
    Burkhardt, F.
    JOURNAL OF CLINICAL VIROLOGY, 2006, 36 : S25 - S25
  • [40] Evaluation of automated nucleic acid extraction devices for application in HCVNAT
    Jongerius, JM
    Bovenhorst, M
    van der Poel, CL
    van Hilten, JA
    Kroes, ACM
    van der Does, JA
    van Leeuwen, EF
    Schuurman, R
    TRANSFUSION, 2000, 40 (07) : 871 - 874