Effects of the operation parameters of a closed-type heating tower on the performance of heating tower heat pump system

被引:0
|
作者
Rong, Feng [1 ,2 ]
Li, Xiuzhen [3 ]
Zhao, Xingcheng [1 ]
Fang, Junfei [1 ,2 ]
机构
[1] Shaanxi Univ Technol, Sch Mech Engn, Hanzhong, Peoples R China
[2] Shaanxi Key Lab Ind Automat, Hanzhong, Peoples R China
[3] Henan Univ Sci & Technol, Inst Refrigerat & Air Conditioning, Luoyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Closed-type heating tower; operation parameters; heat pump system; energy efficiency; coefficient of performance; MASS-TRANSFER CHARACTERISTICS; COOLING-TOWER; FLOW; AIR;
D O I
10.1177/0144598720933698
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The ventilator of the heating tower and the circulating pump of the anti-freeze solution are the main electrical equipment of a heating tower heat pump system, besides the compressor. By controlling the working frequencies of the ventilator of the heating tower and circulating pump of the anti-freeze solution, the effects of the operation parameters of a closed-type heating tower on its heat absorption and the performance of heating tower heat pump system were investigated under winter heat conditions. The results indicated that reducing the frequency of the circulating pump for the anti-freeze solution leads to a decrease in the temperature of the outlet evaporator of the anti-freezing solution and an increased temperature difference between the anti-freeze solution flowing into and out of the heating tower; meanwhile, excessively high and low anti-freeze flow rates lead to reduced heat absorption of the closed-type heating tower. The coefficient of performance fluctuates slightly if the frequency of circulating pump is above 20 Hz, but a slight drop in coefficient of performance is observed when the frequency is less than 15 Hz. The system energy efficiency ratio tends to increase as the frequency of circulating pump is reduced, although a substantial reduction occurs at 10 Hz. Furthermore, a reduced ventilator frequency decreases the temperatures of the anti-freeze solution at the inlet and outlet of the heating tower and the temperature difference, hindering the heat absorption of the heating tower. With reductions in the ventilator frequency, the coefficient of performance exhibits an initial increase followed by subsequent decreases, while the system energy efficiency ratio showed continual increases until the ventilator frequency dropped to 10 Hz. When the ventilator frequency or circulating pump frequency drops to 15 Hz and 10 Hz, the evaporation temperature of the heat pump unit decreases, resulting in an excessively exhaust temperature, which is not favorable for the safe operation of the system.
引用
收藏
页码:1983 / 1997
页数:15
相关论文
共 50 条
  • [41] Low temperature heating operation performance of a domestic heating system based on indirect expansion solar assisted air source heat pump
    Yang, Li Wei
    Li, Yan
    Yang, Tong
    Wang, Hua Sheng
    SOLAR ENERGY, 2022, 244 : 134 - 154
  • [42] Performance of ground source heat pump and floor heating system for venlo greenhouse heating in winter
    Fang Hui
    Yang Qichang
    HORTSCIENCE, 2008, 43 (04) : 1243 - 1243
  • [43] System design and long-term field test for a novel multi-mode heating tower heat pump system in cold regions
    Zhao, Shanguo
    Zhang, Xiaosong
    Liang, Caihua
    Huang, Shifang
    SUSTAINABLE CITIES AND SOCIETY, 2023, 89
  • [44] Optimization of design and operation parameters for hybrid ground-source heat pump assisted with cooling tower
    Cui, Wenzhi
    Zhou, Shiyu
    Liu, Xiangyang
    ENERGY AND BUILDINGS, 2015, 99 : 253 - 262
  • [45] Experimental investigation on the operation performance of a direct expansion ground source heat pump system for space heating
    Wang, Huajun
    Zhao, Qian
    Wu, Juntao
    Yang, Bin
    Chen, Zhihao
    ENERGY AND BUILDINGS, 2013, 61 : 349 - 355
  • [46] MATHEMATICAL-MODELING OF THERMAL PERFORMANCE OF HEATING CHAMBER OF TOWER-TYPE RESISTANCE FURNACE
    MASTRYUKOV, BS
    NEMCHINOV, NF
    TSEITLIN, GA
    BELENKII, AM
    STEEL IN THE USSR, 1981, 11 (05): : 305 - 306
  • [47] Study on Operation Optimization Strategy of Ground Source Heat Pump Heating System
    Chen, Cheng
    Chen, Xingying
    Yu, Kun
    Gan, Lei
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [48] Study of Heat-source-tower Heat Pump System Efficiency
    Cheng, Jianlin
    Li, Nianpin
    Wang, Kuan
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 915 - 921
  • [49] Heating and cooling performance of a minitype ground source heat pump system
    Zhai, X. Q.
    Cheng, X. W.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 1366 - 1370
  • [50] Performance investigation of a combined solar thermal heat pump heating system
    Li, Hong
    Sun, Liangliang
    Zhang, Yonggui
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 460 - 468