Indoor radon measurements in dwellings of Kulu area, Himachal Pradesh, using solid state nuclear track detectors

被引:42
|
作者
Singh, S [1 ]
Malhotra, R [1 ]
Kumar, J [1 ]
Singh, L [1 ]
机构
[1] Guru Nanak Dev Univ, Dept Phys, Amritsar 143005, Punjab, India
关键词
indoor radon; LR-115 type II films; etching;
D O I
10.1016/S1350-4487(01)00216-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the present paper, the results of radon activity recorded in domestic regions of the Kulu area (Himachal Pradesh, India) known for uranium mineralisation are reported. Time integrated track etch technique has been used for the measurement of indoor radon levels. Bare cellulose nitrate LR-115 type II films have been used as detectors in the survey of radon. The calibration constant of 4.8 x 10(2) tracks cm(-2) day(-1) per WL of radon at equilibrium (which corresponds to 12.97 x 10(-2) tracks cm(-2) d(-1) per Bq m(-3)) determined by Subba Ramu et al. (Sci. Total Environ. 73 (1988) 245) has been used to express radon activity in Bq m(-3). In some of the dwellings the levels of radon activity are found to be quite high giving an annual exposure dose that crosses the safety limits set by the International Commission on Radiological Protection (ICRP, Protection against radon-222 at home and at work, ICRP Publication 65, Annals of the ICRP, 23 (2), 1993). A study of seasonal variations of indoor radon in some of the dwellings has also been carried out. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:505 / 508
页数:4
相关论文
共 50 条
  • [21] RADON AND THORON MEASUREMENTS USING NUCLEAR TRACK DETECTORS
    MORSY, AA
    DURRANI, SA
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1985, 81 (01): : 332 - 332
  • [22] ENVIRONMENTAL RADON STUDIES USING SOLID-STATE NUCLEAR TRACK DETECTORS
    RAMOLA, RC
    SINGH, M
    SINGH, S
    VIRK, HS
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1992, 15 (02) : 95 - 102
  • [23] RADON MONITORING WITH SOLID-STATE NUCLEAR TRACK DETECTORS
    STEYN, A
    STRYDOM, R
    HEALTH PHYSICS, 1988, 54 (03): : 357 - 357
  • [24] RADON MONITORING WITH SOLID-STATE NUCLEAR TRACK DETECTORS
    STEYN, A
    STRYDOM, R
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1987, 83 (09) : 571 - 571
  • [25] Measurement of indoor radon and thoron in the dwellings of Faizabad city using plastic track detectors
    Verma, Deepak
    Khan, M. Shakir
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 219 - 222
  • [26] Are solid state nuclear track detectors truly integrated devices?-experimental evidence in radon measurements
    Wasikiewicz, Jaroslaw M.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (06) : 617 - 622
  • [27] Radon dosimetry using Solid State Nuclear Track Detectors in different environments: a review
    Takahashi, Laura Cardoso
    Santos, Talita de Oliveira
    Marques Pinheiro, Rose Mary
    Passos, Ricardo Gomes
    Rocha, Zildete
    APPLIED RADIATION AND ISOTOPES, 2022, 186
  • [28] Study of uranium, radium and radon exhalation rate in soil samples from some areas of Kangra district, Himachal Pradesh, India using solid-state nuclear track detectors
    Sharma, DK
    Kumar, A
    Kumar, M
    Singh, S
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 363 - 366
  • [29] INDOOR RADON MEASUREMENTS WITH TRACK-ETCH DETECTORS
    OSWALD, RA
    ALTER, HW
    GINGRICH, JE
    HEALTH PHYSICS, 1982, 43 (01): : 122 - 122
  • [30] Indoor and soil radon measurements in Swaziland by track detectors
    Farid, SM
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1997, 34 (01) : 29 - 36