Dimensional Optimization in Screw Fixation for Personalized Treatment of the Tibial Plateau Fracture

被引:0
|
作者
Moldovan, Flaviu [1 ]
Gligor, Adrian [2 ]
Bataga, Tiberiu [3 ]
机构
[1] George Emil Palade Univ Med Pharm Sci & Technol T, IOSUD Doctoral Sch, Targu Mures 540139, Romania
[2] George Emil Palade Univ Med Pharm Sci & Technol T, Biomed Res Ctr, Targu Mures 540139, Romania
[3] George Emil Palade Univ Med Pharm Sci & Technol T, Dept Orthoped Traumatol, Targu Mures 540139, Romania
关键词
Orthopedic surgery; Tibial fracture; Screw; Personalized treatment; TRENDS;
D O I
10.1007/978-3-030-93817-8_69
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background: Tibial plateau fractures represent 1% of all fractures in adults, and the aim of the fracture treatment is stable fixation. There is a lack of consensus regarding the optimal treatment method for complex fractures. Closed reduction and percutaneous screw fixation for tibial plateau fractures is minimally invasive and has many advantages. Objective: The aim of this study was to develop a method for the optimal sizing of cannulated cancellous screws for fixing bone fragments of tibial plateau fractures according to the patient's characteristics, followed by a calculation of the crushing strength of bone fragments. Method: The dimensional parameters of the cannulated cancellous screws for fixing fractured bone fragments in the basal bone are the length and diameter. These parameters are determined in the surgical planning stage using virtual models and resistance calculations. Bone fragments fixed with cannulated screws are checked for crushing and the number of screws required to meet the crushing strength condition is calculated. Results: Validation in practice of the methodology for fixing tibial plateau fractures with cannulated cancellous fixation screws was performed in a patient who had a Schatzker type IV fracture. The patient required the fixation of the tibial fracture fragment using a cannulated screw sized with 3 mm diameter and 54 mm length. The crushing verification of the fractured bone fragment was performed according to the methodology developed in this paper. Conclusion: The results indicate that the present methodology is recommended in the preoperative planning stage of the tibial plateau fractures reductions and screw fixations, offering the guarantee of a biomechanical quality fixation which ensures the good health of the patient. It opens new perspectives for fixing optimization and calculating the strength of other types of fractures.
引用
收藏
页码:772 / 783
页数:12
相关论文
共 50 条
  • [41] Biomechanical analysis of posteromedial tibial plateau fracture fixation in fresh cadaveric bone
    Twinprai, Nattaphon
    Twinprai, Prin
    Sripaduangkul, Suwitcha
    Samrid, Rarinthorn
    Nimpisut, Nakarin
    Apinyankul, Rit
    Laonapakul, Teerawat
    Chindaprasirt, Prinya
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (03):
  • [42] A posteromedial approach for open reduction and internal fixation of posteromedial tibial plateau fracture
    Chen, Hong-wei
    Pan, Jun
    Yi, Xian-hong
    Huang, Yi-xing
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (02): : 258 - 264
  • [43] Risk Factors for Knee Stiffness Surgery After Tibial Plateau Fracture Fixation
    Reahl, G. Bradley
    Marinos, Dimitrius
    O'Hara, Nathan N.
    Howe, Andrea
    Degani, Yasmin
    Wise, Brent
    Maceroli, Michael
    O'Toole, Robert V.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (09) : E339 - E343
  • [44] Fixation of tibial plateau fracture - risk factors for developing infection: a narrative review
    Franulic, Nicolas
    Munoz, Jose Tomas
    Pineda, Tomas
    Laso, Jose
    Olivieri, Rodrigo
    Schroeter, Steffen
    EFORT OPEN REVIEWS, 2024, 9 (12) : 1170 - 1178
  • [45] Anterolateral tibial plateau osteotomy as a new approach for the treatment of posterolateral tibial plateau fracture A case report
    Sun, Da-Hui
    Zhao, Yi
    Zhang, Ji-Ting
    Zhu, Dong
    Qi, Bao-Chang
    MEDICINE, 2018, 97 (03)
  • [46] Determination of Posterior Tibial Slope Changes After Tibial Plateau Fracture Fixation: A Retrospective Case Series
    Mohammad Fakoor
    Mohammad Ghassem Hanafi
    Payam Mohammadhoseini
    Meghdad Variani
    Maryam Moradi
    Indian Journal of Orthopaedics, 2023, 57 : 1485 - 1489
  • [47] Determination of Posterior Tibial Slope Changes After Tibial Plateau Fracture Fixation: A Retrospective Case Series
    Fakoor, Mohammad
    Hanafi, Mohammad Ghassem
    Mohammadhoseini, Payam
    Variani, Meghdad
    Moradi, Maryam
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (09) : 1485 - 1489
  • [48] Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study
    Cift, H.
    Cetik, O.
    Kalaycioglu, B.
    Dirikoglu, M. H.
    Ozkan, K.
    Eksioglu, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) : 263 - 267
  • [49] Biomechanical comparison of screw versus screw-plate fixation of type 2 Schatzker fractures of the lateral tibial plateau
    Boisrenoult, P
    Bricteux, S
    Beaufils, P
    Hardy, P
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (07): : 707 - 711
  • [50] Lateral Tibial Plateau Fracture
    Flautt, Warren
    Miller, Joseph
    Ratcliff, Jennifer Robyn
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2012, 42 (09): : 819 - 819