Comparison of full-field electroretinogram in diabetic and non diabetic dogs with cataracts

被引:1
|
作者
Safatle, Angelica M. V. [1 ]
Hvenegaard, Ana Paula [1 ]
Otsuki, Denise [2 ]
Martins, Terezinha L. [2 ]
Kahvegian, Marcia [2 ]
Berezovsky, Adriana [3 ]
Salomao, Solange R. [3 ]
Barros, Paulo S. M. [1 ]
机构
[1] Univ Sao Paulo, Labo Invest Oftalmol Comparada, Dept Cirurgia, Fac Med Vet & Zootecnia, BR-05508270 Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Med, BR-05403000 Sao Paulo, Brazil
[3] Univ Fed Sao Paulo Unifesp, Escola Paulista Med, BR-04023900 Sao Paulo, Brazil
来源
PESQUISA VETERINARIA BRASILEIRA | 2010年 / 30卷 / 12期
基金
巴西圣保罗研究基金会;
关键词
Electroretinogram; dogs; cataracts; diabetes mellitus; diabetic retinopathy; retina; MELLITUS;
D O I
10.1590/S0100-736X2010001200012
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Safatle A.M.V., Hvenegaard A.P., Otsuki D., Martins T.L., Kahvegian M., Berezovsky A., Salomao S.R. & Barros P.S.M. 2010. Comparison of full-field electroretinogram in diabetic and non diabetic dogs with cataracts. Pesquisa Veterinaria Brasileira 30(12):1071-1076. Laboratory of Investigation in Comparative Ophthalmology, Veterinary Teaching Hospital, School of Veterinary Medicine, University of Sao Paulo, Av. Prof. Dr. Orlando de Marques de Paiva 87, Bloco 8 superior, Cidade Universitaria, Sao Paulo, SP 05508-270, Brazil. E-mail: angsaf@usp.br Being the commonest ocular disorder, dense cataracts disable fundoscopic examination and the diagnosis of retinal disorders, which dogs may be predisposed. The aim of this study was to compare the electroretinographic responses recorded according to the International Society for Clinical Electrophysiology of Vision human protocol to evaluate retinal function of diabetic and non diabetic dogs, both presenting mature or hypermature cataracts. Full-field electroretinogram was recorded from 66 dogs, with ages varying from 6 to 15 years old allocated into two groups: (1) CG, non diabetic cataractous dogs, and (2) DG, diabetic cataractous dogs. Mean peak-to-peak amplitude (microvolts) and b-wave implicit time (milliseconds) were determined for each of the five standard full-field ERG responses (rod response, maximal response, oscillatory potentials, single-flash cone response and 30 Hz flicker). Comparing CG to DG, ERGs recorded from diabetic dogs presented lower amplitude and prolonged b-wave implicit time in all ERG responses. Prolonged b-wave implicit time was statistically significant (p< 0.05) at 30 Hz flicker (24.0 ms versus 22.4 ms). These data suggests full-field ERG is capable to record sensible alterations, such as flicker's implicit time, being useful to investigate retinal dysfunction in diabetic dogs.
引用
收藏
页码:1071 / 1076
页数:6
相关论文
共 50 条
  • [41] ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram
    Laura Frishman
    Maja Sustar
    Jan Kremers
    J. Jason McAnany
    Marc Sarossy
    Radouil Tzekov
    Suresh Viswanathan
    Documenta Ophthalmologica, 2018, 136 : 207 - 211
  • [42] The Stiles-Crawford effect of the first kind and the full-field electroretinogram (ERG)
    McCulloch, Daphne L.
    Lakshminarayanan, Vasudevan
    JOURNAL OF MODERN OPTICS, 2009, 56 (20) : 2176 - 2180
  • [43] Voluntary alteration of full-field electroretinogram (ERG) and visual evoked potential (VEP)
    Reiss, A
    Biousse, V
    Barnes, CS
    Yang, H
    Nakamoto, B
    Newman, NJ
    NEUROLOGY, 2004, 62 (07) : A63 - A63
  • [44] Spectral characteristics of the PhNR in the full-field flash electroretinogram of normals and glaucoma patients
    Jan Kremers
    Mounira Jertila
    Barbara Link
    Gobinda Pangeni
    Folkert K. Horn
    Documenta Ophthalmologica, 2012, 124 : 79 - 90
  • [45] Full-field electroretinogram severity is associated with visual prognosis in Japanese AZOOR patients
    Hirakata, Toshiaki
    Hara, Fumihiro
    Hiratsuka, Yoshimune
    Murakami, Akira
    Nakao, Shintaro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [46] Spectral characteristics of the PhNR in the full-field flash electroretinogram of normals and glaucoma patients
    Kremers, Jan
    Jertila, Mounira
    Link, Barbara
    Pangeni, Gobinda
    Horn, Folkert K.
    DOCUMENTA OPHTHALMOLOGICA, 2012, 124 (02) : 79 - 90
  • [47] Role of a mydriasis-free, full-field flicker ERG device in the detection of diabetic retinopathy
    Mehmet Fatih Kağan Değirmenci
    Sibel Demirel
    Figen Batıoğlu
    Emin Özmert
    Documenta Ophthalmologica, 2018, 137 : 131 - 141
  • [48] Role of a mydriasis-free, full-field flicker ERG device in the detection of diabetic retinopathy
    Degirmenci, Mehmet Fatih Kagan
    Demirel, Sibel
    Batioglu, Figen
    Ozmert, Emin
    DOCUMENTA OPHTHALMOLOGICA, 2018, 137 (03) : 131 - 141
  • [49] ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram
    Frishman, Laura
    Sustar, Maja
    Kremers, Jan
    McAnany, J. Jason
    Sarossy, Marc
    Tzekov, Radouil
    Viswanathan, Suresh
    DOCUMENTA OPHTHALMOLOGICA, 2018, 136 (03) : 207 - 211
  • [50] Full-field electroretinogram and multifocal electroretinogram in carrier of sex-linked and autosomal resessive retinitis pigmentosa.
    Cheung, SC
    Lam, TS
    Leung, KW
    To, CH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S894 - S894