Basic imaging properties of a new screen-film system for chest radiography

被引:3
|
作者
Higashida, Y
Murakami, Y
Yoshida, A
Kastuda, N
Moribe, N
Bussaka, H
Hamada, T
Yoshida, Y
Hidetoshi, M
Takahashi, M
机构
[1] Dept. of Radiological Technology, Kumamoto University, College of Medical Science, Kumamoto 862
[2] Department of Radiology, O-ita Medical University, O-ita 879-56
[3] Dept. Radiological Sci. and Technol., Hiroshima Pref. Coll. Hlth. Welf., Mihara Hiroshima 723
[4] Department of Radiology, Kumamoto University Hospital, Kumamoto 860
关键词
screen-film system; chest radiography; resolution property; noise Wiener spectrum; radiological visibility;
D O I
10.1118/1.597709
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the potential clinical usefulness of a new screen-film system (advanced screen-film system; AD system) for chest radiography, its fundamental imaging properties compared with a conventional screen-film system (HR-4/HR-S) were investigated. The basic imaging properties were evaluated by measuring characteristic (H&D) curves, relative speeds, MTFs (modulation transfer functions), WS (Wiener spectra), and x-ray attenuations of screens. The detail visibilities and pathological details of various diseases in chest radiographs of patients were evaluated subjectively. The film gradient of the AD system was slightly lower at low radiographic density, and higher at high density, as compared with a conventional screen-film system. The screen speed of the AD system was 212% greater than that of the conventional system and the film speed was 53% that of the conventional film. As the result the total speed of the AD system was slightly higher compared with the conventional system. The spatial resolution of the AD system was comparable to or slightly lower than that of the conventional system. The noise level of the AD system was considerably lower than that of the conventional system at low (D=0.5) and middle (D=1.0) radiographic density levels. However, it was high at high radiographic density (D=1.8). The radiographic densities in the underpenetrated areas with the AD system were greater than those of the conventional system when the lung densities are matched comparable. Improvement in noise level with the AD system at low and middle density levels may be useful for detection of various diseases in chest radiographs. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1351 / 1357
页数:7
相关论文
共 50 条
  • [1] EVALUATION OF AN ASYMMETRIC SCREEN-FILM SYSTEM FOR CHEST RADIOGRAPHY
    MORISHITA, J
    MACMAHON, H
    DOI, K
    CARLIN, M
    SUKENOBU, Y
    MEDICAL PHYSICS, 1994, 21 (11) : 1769 - 1775
  • [2] EVALUATION OF ASYMMETRIC SCREEN-FILM SYSTEM FOR CHEST RADIOGRAPHY
    MORISHITA, J
    MACMAHON, H
    DOI, K
    RADIOLOGY, 1992, 185 : 250 - 250
  • [3] COMPARISON OF BASIC IMAGING PROPERTIES FOR NEW SCREEN-FILM SYSTEMS
    YOSHIDA, A
    HIGASHIDA, Y
    OTSUKA, A
    KODERA, Y
    ASAHARA, M
    MURAKAMI, Y
    RADIOLOGY, 1995, 197 : 449 - 449
  • [4] DETECTION OF SIMULATED CHEST LESIONS - COMPARISON OF A CONVENTIONAL SCREEN-FILM COMBINATION, AN ASYMMETRIC SCREEN-FILM SYSTEM, AND STORAGE PHOSPHOR RADIOGRAPHY
    LEPPERT, AGA
    PROKOP, M
    SCHAEFERPROKOP, CM
    GALANSKI, M
    RADIOLOGY, 1995, 195 (01) : 259 - 263
  • [5] Comparison of an asymmetric screen-film combination with a conventional screen-film combination for chest radiography in 51 patients
    Greaney, T
    McCoy, C
    Masterson, J
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (837): : 929 - 932
  • [6] TWIN SCREEN-FILM CHEST RADIOGRAPHY - COST-EFFECTIVE LUNG AND MEDIASTINAL IMAGING
    MCLEAN, ID
    GRAY, JE
    SWENSEN, SJ
    RADIOLOGY, 1994, 190 (02) : 622 - 622
  • [7] THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY
    DOBBINS, JT
    RICE, JJ
    BEAM, CA
    RAVIN, CE
    RADIOLOGY, 1992, 183 (01) : 179 - 187
  • [8] A NEW ASYMMETRIC SCREEN-FILM COMBINATION FOR CONVENTIONAL CHEST RADIOGRAPHY - EVALUATION IN 50 PATIENTS
    SWENSEN, SJ
    GRAY, JE
    BROWN, LR
    AUGHENBAUGH, GL
    HARMS, GF
    STEARS, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 483 - 486
  • [9] Technical aspects of twin screen-film chest radiography: cost effective lung and mediastinal imaging
    McLean, D
    Gray, JE
    Swensen, SJ
    Vrieze, TJ
    EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 (01) : 53 - 60
  • [10] Clinical evaluation of twin screen-film chest radiography: cost effective lung and mediastinal imaging
    McLean, D
    Gray, JE
    Swensen, SJ
    Vrieze, TJ
    EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 (01) : 61 - 66