摘要
Maintenance is a complicated task that encompasses various activities including fault detection, fault diagnosis, and fault reparation. The advancement of Computer Aided Engineering (CAE) has increased challenges in maintenance as modern assets have became complex mixes of systems and sub systems with complex interaction. Among maintenance activities, fault diagnosis is particularly cumbersome as the reason of failures on the system is often neither obvious in terms of their source nor unique. Early detection and diagnosis of such faults is turning to one of the key requirements for economical and functional asset efficiency. Several methods have been investigated to detect machine faults for a number of years that are relevant for many application domains. In this paper, we present the process history-based method adopting nominal efficiency of Air Handling Unit (AHU) to detect heat recovery failure using Principle Component Analysis (PCA) in combination of the logistic regression method.
引用
收藏
页码:343 / 350
页数:8
相关论文
共 50 条
  • [21] The air-conditioner system with a kind of waste heat recovery unit
    Hu, XH
    Shu, SM
    [J]. ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1063 - 1065
  • [22] APPLICATION OF A HEAT PUMP RECOVERY FRESH AIR UNIT IN RESIDENTIAL BUILDING
    Wang, Chunqing
    Ran, Chunyu
    Zhang, Lan
    Ge, Fenghua
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1724 - 1731
  • [23] Cooling output optimization of an air handling unit
    Kusiak, Andrew
    Li, Mingyang
    [J]. APPLIED ENERGY, 2010, 87 (03) : 901 - 909
  • [24] Air Handling Unit Design for Energy Conservation
    Wheeler, Arthur E.
    [J]. ASHRAE JOURNAL, 2009, 51 (02) : 40 - +
  • [25] Re-commissioning of an air handling unit
    Cuevas, C
    Lebrun, J
    Lacôte, P
    Andre, P
    [J]. ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 147 - 155
  • [26] Online fault detection and diagnosis in VAV air handling unit by RARX modeling
    Yoshida, H
    Kumar, S
    Morita, Y
    [J]. ENERGY AND BUILDINGS, 2001, 33 (04) : 391 - 401
  • [27] HUNTER AIR-LIFT HANDLING UNIT
    不详
    [J]. MACHINERY AND PRODUCTION ENGINEERING, 1972, 121 (3116): : 160 - &
  • [28] Numerical Modeling and Optimization of an Air Handling Unit
    Lopes, Jose
    Silva, Joao
    Teixeira, Senhorinha
    Teixeira, Jose
    [J]. ENERGIES, 2021, 14 (01)
  • [29] Primary Frequency Control with an Air Handling Unit
    Karhula, Niko
    Sierla, Seppo
    Ihasalo, Heikki
    Ketomaki, Jaakko
    Huotari, Matti
    Vyatkin, Valeriy
    [J]. ENERGIES, 2024, 17 (15)
  • [30] A New Electrical Method on Airflow Fault Detection of Air Handling Unit (AHU)
    He, Dawei
    Jiang, Chen
    Harley, Ronald G.
    Habetler, Thomas G.
    Ding, Ran
    [J]. 2015 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2015,