Protection Coordination Method Using Symmetrical Components in Loop Distribution System

被引:2
|
作者
Lee, Jung-Hun [1 ]
Kim, Woo-Hyun [1 ]
Lee, Hak-Ju [1 ]
Kim, Jun-Oh [2 ]
Chae, Woo-Kyu [1 ]
机构
[1] KEPCO Res Inst, Smart Power Distribut Lab, Distribut Planning Grp, Daejeon 34056, South Korea
[2] Korea Elect Power Corp, Daegu 41590, South Korea
关键词
protection coordination; loop distribution system; symmetric component; distributed generations; STRATEGY;
D O I
10.3390/en14164947
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Power utilities worldwide commonly use the radial distribution system because of its advantages of being simple in structure and having relatively inexpensive installation costs. It has a disadvantage in that its power supply reliability is low because the load side of the fault section will suffer from an outage in the event of a fault in the system. However, recently, with ICT (Information and Communication Technologies) development, system reliability is required to be high as the outage-susceptible loads increase. In addition, the increase in the connection of distributed resources such as renewable energy and electric vehicles is making it impossible to predict the power flow and reducing line utilization. Therefore, a loop power distribution system is proposed as a measure to solve this problem. Because all buses (nodes) in a loop distribution system have two or more power supply routes, they are more reliable than the radial system. It allows them to improve line utilization by connecting lines with different load peak times. However, in the case of a fault in the loop distribution system, the fault current is supplied from both directions, making it impossible to properly isolate the fault section with the protection method of the conventional distribution system. The permissive overreach transfer trip (POTT) method using communication to compensate for the limitations of conventional protection devices, and the other method using directional distance relay, is proposed. However, these methods operate by determining the direction of the fault current but have a disadvantage. It is difficult to detect a fault due to the effects of ground faults and distributed generation (DG) occurring in other lines. Therefore, in this paper, we propose a protection coordination algorithm that uses the negative-sequence component of voltage and current that occur when an unbalanced fault occurs, rather than the determination of the directionality and use of communication. To validate this, we configured a system using PSCAD/EMTDC (Manitoba Hydro International Ltd., Winnipeg, Manitoba, Canada), a system analysis program package and verified the results depending on the type of faults with the proposed algorithm.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A priority based approach for protection coordination in distribution system
    Solat, Sajjad
    [J]. 2015 20TH CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2015, : 131 - 137
  • [22] Software for automatic coordination of protection devices in distribution system
    Comassetto, L.
    Bernardon, D. P.
    Canha, L. N.
    Abaide, A. R.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2241 - 2246
  • [23] Protection scheme based on IoT in loop distribution system
    Seo, Hun-Chul
    [J]. Transactions of the Korean Institute of Electrical Engineers, 2020, 69 (06): : 752 - 758
  • [24] Application of Kalman filtering for online estimation of symmetrical components for power system protection
    Soliman, SA
    ElHawary, ME
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1996, 38 (02) : 113 - 123
  • [25] Advanced symmetrical components method
    Strezoski, V. C.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (08) : 833 - 841
  • [26] Analysis of Fault Current Limiting on the Protection Coordination System at Distribution System
    Willy, Muhammad Afif S.
    Gumilar, Langlang
    Sujito
    [J]. 2021 7TH INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND INFORMATION ENGINEERING (ICEEIE 2021), 2021, : 72 - 77
  • [27] A CT saturation detection algorithm using symmetrical components for current differential protection
    Villamagna, N
    Crossley, PA
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) : 38 - 45
  • [28] Using Symmetrical Components For Internal External Fault Discrimination in Differential Protection Schemes
    Rizvi, Imran A.
    Reeser, Gerry
    [J]. 2013 66TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2013, : 68 - 79
  • [29] DeviceNet fieldbus and symmetrical components method used in motor protection measurement and control device
    Depart of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China
    不详
    [J]. Yi Qi Yi Biao Xue Bao, 2006, SUPPL. (2427-2428+2431):
  • [30] Analysis on Protection Coordination of OCRs in Power Distribution System with SFCL
    Cho, Yoo-Jung
    Park, Min-Ki
    Lim, Sung-Hun
    [J]. Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (12): : 1746 - 1752