Design of micro-displacement amplifier for the micro-channel cooling system in the micro-pump

被引:5
|
作者
Zhang, Yunliang [1 ]
Li, Dezhi [1 ]
Chen, Yuan [1 ]
Zhang, Bin [1 ]
机构
[1] Shandong Univ, Sch Mech Elect & Informat Engn, Weihai 264209, Peoples R China
来源
关键词
OPTIMIZATION;
D O I
10.1007/s10010-020-00394-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
With the characteristic of small size, lightweight, low energy dissipation, the laminated piezoelectric is suitable for micro-electromechanical system, which still needs an external amplification mechanism because of its low output displacement. As for the application of the micro-channel cooling system in the micro-pump, the leveraged mechanism, the bridge mechanism and the hydraulic mechanism have been proceed numerical modeling, dynamic simulation and optimizing in this paper. In this study, the amplifier is designed within the volume of 15x202f;mmx202f;x 15x202f;mmx202f;x 5x202f;mm. The volume of the leveraged mechanism, the bridge mechanism and the hydraulic mechanism are 345x202f;mm(3), 1125x202f;mm(3) and 240.21x202f;mm(3) respectively. Moreover, the best magnification and frequency for the above three magnifying mechanisms are 134.8 and 69.4x202f;Hz, 61.52 and 5.26x202f;kHz, 50.6 and 6.94x202f;kHz respectively. The performance of a micro-pump is a combination of the output quantity per time and the output frequency. Compared to other two magnifying mechanisms, the hydraulic mechanism is smaller, more stable and faster in response. Taking into consideration all these above factors, the hydraulic mechanism is more suitable for the micro-pump used in a micro-channel cooling system. The hydraulic micro-displacement amplifying mechanism also can be used in developing tools for other fields such as medicine, chemistry and so on.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [41] Polypyrrole actuators for micro-pump applications
    Travas-Sejdic, Jadranka
    Kiefer, Rudolf
    Valiavalappil, Sreejith
    Li, Kwong-chi
    Kilmartin, Paul A.
    SMART STRUCTURES AND MATERIALS 2006: ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD), 2006, 6168
  • [42] The Micro-displacement Worktable Control System of Mirror Detection
    Ye, Yu
    Zhang, Zhenchao
    Li, Aihua
    ADVANCED SOFTWARE AND CONTROL FOR ASTRONOMY II, PTS 1 & 2, 2008, 7019
  • [43] Neuron PSD control for piezoelectric micro-displacement system
    Gong, C. K.
    Chen, D. J.
    4th International Symposium on Instrumentation Science and Technology (ISIST' 2006), 2006, 48 : 1107 - 1111
  • [44] Precise PSD micro-displacement online measurement system
    Song, Dianyou
    Liu, Tiegen
    Ding, Xiaokun
    Li, Zhihong
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2013, 46 (02): : 168 - 173
  • [45] Piezoelectric micro-pump for insulin injection
    College of Mechanical Science and Engineering, Jilin University, Changchun 130022, China
    Jilin Daxue Xuebao (Gongxueban), 2007, 2 (372-376):
  • [46] Mytilus galloprovincialis as a smart micro-pump
    Uslu, Fazil E.
    Pekkan, Kerem
    BIOLOGY OPEN, 2016, 5 (10): : 1493 - 1499
  • [47] Optimization of the Performance of a Biomedical Micro-Pump
    Bourbaba, E.
    Bouanini, M.
    Benachaiba, C.
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2016, 10 (02) : 205 - 213
  • [48] Micro-displacement measurements with holographic gratings
    Gómez-Colín, MR
    Olivares-Pérez, A
    Sánchez-Villicaña, V
    PRACTICAL HOLOGRAPHY XV AND HOLOGRAPHIC MATERIALS VII, 2001, 4296 : 108 - 115
  • [49] Identification of the Servomechanism used for micro-displacement
    Bogdan, Ioana-Corina
    Abba, Gabriel
    2009 IEEE-RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2009, : 1986 - 1991
  • [50] Design, manufacture and testing of a low-cost micro-channel cooling device
    Pang, AJ
    Desmulliez, MPY
    Leonard, M
    Dhariwal, RS
    Reuben, RL
    Holmes, AS
    Hong, G
    Pullen, KR
    Waldron, F
    Slattery, O
    Rencz, M
    Emerson, DR
    Barber, RW
    6TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, PROCEEDINGS (EPTC 2004), 2004, : 564 - 568