HVAC energy savings, thermal comfort and air quality for occupant-centric control through a side-by-side experimental study

被引:69
|
作者
Kong, Meng [1 ,2 ]
Dong, Bing [1 ]
Zhang, Rongpeng [2 ]
O'Neill, Zheng [3 ]
机构
[1] Syracuse Univ, Dept Mech & Aerosp Engn, 223 Link Hall, Syracuse, NY 13244 USA
[2] Delos Living LLC, Well Living Lab, 221 First Ave SW Ste 100, Rochester, MN 55902 USA
[3] Texas A&M Univ, J Mike Walker 66 Dept Mech Engn, College Stn, TX 77843 USA
关键词
Occupancy sensing; Occupancy-based control; Side-by-side experiment; Energy savings; Thermal comfort; Indoor air quality; PREDICTIVE CONTROL; SBS SYMPTOMS; PRODUCTIVITY; POLLUTION; BEHAVIOR;
D O I
10.1016/j.apenergy.2021.117987
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building sensing technologies have evolved rapidly in the last two decades in aid of monitoring building envi-ronment and energy system performance. A series of occupancy sensing systems were developed to track the occupant behavior in the indoor space. Occupancy-based building system control is defined as a control method that adjusts the building system operation schedules and setpoints based on the measured occupant behavior and has been identified as a smart building control strategy that can improve building energy efficiency as well as occupant comfort. Some studies demonstrated energy-saving potential and comfort-maintaining capability from occupancy-based control. This study adopted a first-of-its-kind side-by-side experimental approach to quantify the performance of the occupancy-based control in commercial buildings. Three state-of-the-art occupancy sensing technologies were integrated into the real-time Heating, Ventilation, and Air-Conditioning (HVAC) system control in this study. Their detection accuracy and its effectiveness on energy-saving and thermal comfort were analyzed. It was found that the occupancy-based control can maintain good thermal comfort and perceived indoor air quality with a satisfaction ratio greater than 80%. Although the daily energy-saving varied with oc-cupancy sensor accuracy and outdoor environment conditions, the weekly averaged energy saving was between 17 and 24%.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] HVAC systems and thermal comfort in buildings climate control: An experimental case study
    Solano, J. C.
    Caamano-Martin, E.
    Olivieri, L.
    Almeida-Galarraga, D.
    ENERGY REPORTS, 2021, 7 : 269 - 277
  • [32] HVAC systems and thermal comfort in buildings climate control: An experimental case study
    Solano, J. C.
    Caamano-Martin, E.
    Olivieri, L.
    Almeida-Galarraga, D.
    ENERGY REPORTS, 2021, 7 : 269 - 277
  • [33] Experimental Analysis of Occupant Feedback Based Model Predictive Control for Thermal Comfort and Energy Optimization
    Chen, Xiao
    Wang, Qian
    Srebric, Jelena
    2016 AMERICAN CONTROL CONFERENCE (ACC), 2016, : 1485 - 1491
  • [34] The experimental research on the thermal comfort under the modes of diffuser and side air supply in summer of Chongqing
    Zhuang, Chunlong
    Li, Baizhan
    Wu, Xiangsheng
    Cheng, Zhili
    Zhang, Hongyu
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 595 - 601
  • [35] Experimental Study of the Aerodynamic Interaction between Side-by-Side Propellers in eVTOL Airplane Mode through Stereoscopic Particle Image Velocimetry
    Zanotti, Alex
    AEROSPACE, 2021, 8 (09)
  • [36] Analysis of the Interplay between Indoor Air Quality and Thermal Comfort in University Classrooms for Enhanced HVAC Control
    Lamberti, Giulia
    Leccese, Francesco
    Salvadori, Giacomo
    Energies, 2024, 17 (20)
  • [37] Occupant feedback based model predictive control for thermal comfort and energy optimization: A chamber experimental evaluation
    Chen, Xiao
    Wang, Qian
    Srebric, Jelena
    APPLIED ENERGY, 2016, 164 : 341 - 351
  • [38] THE FUNCTIONAL BASIS OF STEADY-STATE THERMAL-ENERGY USE IN AIR-SIDE HVAC EQUIPMENT
    REDDY, TA
    KATIPAMULA, S
    KISSOCK, JK
    CLARIDGE, DE
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (01): : 31 - 39
  • [39] Numerical study of two-axis adaptive HVAC vents in developing uniform thermal comfort and improving energy savings
    Chan, Phil S. -T.
    Thou, Edwin M. -C.
    Bong, Victor N. -S.
    Chong, Kok-Hing
    Wong, Basil T.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (01) : 89 - 110
  • [40] Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system
    Che, Wen Wei
    Tso, Chi Yan
    Sun, Li
    Ip, Danny Y. K.
    Lee, Harry
    Chao, Christopher Y. H.
    Lau, Alexis K. H.
    ENERGY AND BUILDINGS, 2019, 201 : 202 - 215