Real-time advanced spectroscopic monitoring of Ammonia concentration in water

被引:10
|
作者
Goldshleger, Naftaly [2 ]
Grinberg, Aharon [1 ,3 ]
Harpaz, Sheenan [3 ]
Shulzinger, Alexander [1 ]
Abramovich, Amir [1 ]
机构
[1] Ariel Univ, Dept Elect & Elect Engn, Ariel, Israel
[2] Ariel Univ, Dept Civil Engn, Ariel, Israel
[3] Agr Res Org, Volcani Ctr, Rishon Letsiyon, Israel
关键词
Toxic Ammonia monitoring; FTIR; Spectral signature; Total Ammonia nitrogen (TAN);
D O I
10.1016/j.aquaeng.2018.10.002
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A direct method for real-time monitoring of Ammonia (NH3) concentration in fish ponds is demonstrated in this study. The method is based on monitoring the spectral signature of pure NH3 in the mid and far infrared (MIR and FIR, respectively) spectrum. A vacuum pump was used to evaporate the pond water. The evaporated water was transferred to a special gas cell for spectroscopic measurement. A linear relationship between NH3 concentration during the evaporation process and the detected signal was found. NH3 concentrations in the order of 1 PPM were detected with excellent agreement (< +/- 5%) to conventional methods. Further improvement model can be achieved if longer interaction paths are used. The advantages of the presented method are: direct measurement of NH3 rather than the indirect calculations and measurements currently used. Better accuracy, and real-time operation is achieved with no maintenance required. The disadvantages of the suggested method are: need for calibration and minor complexity with the vacuum unit.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [21] ADVANCED CLINICAL MONITORING - CONSIDERATIONS FOR REAL-TIME HEMODYNAMIC DIAGNOSTICS
    GOLDMAN, JM
    CORDOVA, MJ
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1994, : 752 - 755
  • [22] ADVANCED REAL-TIME MONITORING AND HEALTH ASSESSMENT OF GEOTECHNICAL SYSTEMS
    Abdoun, Tarek
    Bennett, Victoria
    ADVANCES IN GROUND TECHNOLOGY AND GEO-INFORMATION, 2012, : 3 - 13
  • [23] Monitoring and modeling silicon homoepitaxy breakdown with real-time spectroscopic ellipsometry
    Teplin, CW
    Levi, DH
    Iwaniczko, E
    Jones, KM
    Perkins, JD
    Branz, HM
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (10)
  • [24] Spectroscopic probes for real-time monitoring of polymer modification and degradation reactions
    George, Graerrie
    Hynard, Nikole
    Cash, Greg
    Rintoul, Llew
    O'Shea, Mike
    COMPTES RENDUS CHIMIE, 2006, 9 (11-12) : 1433 - 1443
  • [25] REAL-TIME MONITORING
    BLACKBUM, JP
    INTENSIVE CARE MEDICINE, 1979, 5 (03) : 158 - 158
  • [26] REAL-TIME MONITORING
    Thayer, Ann M.
    CHEMICAL & ENGINEERING NEWS, 2014, 92 (47) : 8 - 12
  • [27] Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
    Zhuang, Shaojie
    Van Overbeke, Philippe
    Vangeyte, Jurgen
    Sonck, Bart
    Demeyer, Peter
    SENSORS, 2019, 19 (17)
  • [28] Real-time monitoring method for gadolinium concentration in a water Cherenkov detectorReal-time monitoring method for gadolinium concentration in a water Cherenkov detectorY. Iwata et al.
    Yoshihiro Iwata
    Hiroyuki Sekiya
    Chikara Ito
    Applied Physics A, 2025, 131 (3)
  • [29] Real-time Monitoring of Surface Water Quality Water Downstream of a Mine
    Palmroth, Marja
    Huttunen, Harri
    Rissanen, Reetaleena
    Rantala, Lasse
    Niskanen, Ilpo
    MINE WATER AND THE ENVIRONMENT, PROCEEDINGS, 2008, : 77 - +
  • [30] Functionalised microwave sensors for real-time monitoring of copper and zinc concentration in mining-impacted water
    Frau, I
    Wylie, S. R.
    Byrne, P.
    Cullen, J. D.
    Korostynska, O.
    Mason, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2020, 17 (04) : 1861 - 1876