Design and Simulation Study of Excitation Coil System with Different Array Configurations for Magnetic Particle Imaging Application

被引:0
|
作者
Birahim, Muhd Fikri Shahkhirin [1 ]
Othman, Nurmiza [1 ,2 ]
Sapuan, Syarfa Zahirah [1 ,2 ]
Tomari, Mohd Razali Md [1 ,2 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Fac Elect & Elect Engn, Batu Pahat 86400, Johor, Malaysia
[2] Univ Tun Hussein Onn Malaysia, Ctr Electromagnet Compatibil EMC, Batu Pahat 86400, Johor, Malaysia
来源
关键词
Magnetic Particle Imaging (MPI); Magnetic nanoparticles (MNPs); 3D analysis; COPPER; RESOLUTION; CORE;
D O I
10.30880/ijie.2020.12.03.032
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Magnetic Particle Imaging (MPI) is a tomographic imaging method has been introduced for three-dimensional (3D) imaging of human body with some potential applications such as magnetic hyperthermia and cancer imaging. It involves three important elements; tracer development using magnetic nanoparticles (MNPs), hardware realization (scanner using excitation and pickup coils), and image reconstruction optimization. Their combination will produce a high-quality image taken from any biological tissue in the human body based on the secondary magnetic field signal from the magnetized MNPs that are injected into human body. A homogeneous and adequate magnetic field strength from an excitation coil is needed to enhance the quality of the secondary signal. However, the complex surface topography of human body and physical properties of an excitation coil influence the strength and the homogeneity of the magnetic field generation at the MNPs. Therefore, this paper presents a new concept of excitation coil configuration to improve the magnetic field strength and the homogeneity to obtain better magnetization of MNPs to be detected in MPI. Two designs will be proposed with variation in physical properties and coil arrangement based on simulation study that will be carried out by using ANSYS Maxwell to generate magnetic field strength and homogeneity towards the targeted distance of 10 mm - 50 mm below the coils. The obtained magnetic field from the simulation was validated by the mathematical calculation using Biot-Savart Law equation. As a result, the new concept of excitation coil configuration proposed can be used to improve the MPI scanner system performance for various medical application.
引用
收藏
页码:278 / 286
页数:10
相关论文
共 50 条
  • [31] Copper coil magnetic system study in a 60 GHz gyrotron design
    Alberto Gonzalez, Jorge
    Salvador, Max
    Morones Ibarra, Jose
    Nieto, Alejandro
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2023, 71 (02) : 103 - 116
  • [32] Run-around coil ventilation heat recovery system: A comparative study between different system configurations
    Wallin, Jorgen
    Madani, Hatef
    Claesson, Joachim
    APPLIED ENERGY, 2012, 90 (01) : 258 - 265
  • [33] SIMULATION STUDY OF A SINGLE-SIDED MAGNETIC PARTICLE IMAGING DEVICE
    Mrongowius, Julia
    Graefe, Ksenija
    Buzug, Thorsten M.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [34] Design, construction and validation of a magnetic particle imaging (MPI) system for human brain imaging
    Mattingly, Eli
    Sliwiak, Monika
    Mason, Erica
    Chacon-Caldera, Jorge
    Barksdale, Alex
    Niebel, Frauke H.
    Herb, Konstantin
    Graeser, Matthias
    Wald, Lawrence L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [35] A Study on the Design and Comparison of 1-100-MJ-Class SMES Magnet With Different Coil Configurations
    Xu, Ying
    Ren, Li
    Tang, Yuejin
    Xu, Chen
    Zhang, Zhongping
    Chen, Wei
    Li, Jingdong
    Shi, Jing
    Chen, Lei
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (05)
  • [36] Non-FFP-Based Magnetic Particle Imaging (NFMPI) with an Open-Type RF Coil System: A Feasibility Study
    Kim, Chan
    Nan, Jiyun
    Nguyen, Kim Tien
    Park, Jong-Oh
    Choi, Eunpyo
    Kim, Jayoung
    SENSORS, 2025, 25 (03)
  • [37] Design of Robust Control System of Magnetic Suspension and Balance System through Harmonic Excitation Simulation
    Lee, Dong-Kyu
    AEROSPACE, 2021, 8 (10)
  • [38] Array Coil Design and Experimental Verification for Separation of Tower Grounding Pulsed Eddy Current Excitation and Response Magnetic Field Signals
    Zeng, Zhiwu
    Guo, Zheng
    Gan, Fan
    Zuo, Yun
    Tian, Xu
    Wang, Xinxun
    Lin, Zhichi
    Zhu, Wanyi
    Wang, Xiaotian
    Wang, Jingang
    ENERGIES, 2025, 18 (02)
  • [39] Design and Simulation of a Battery Powered Electric Vehicle Implementing Two Different Propulsion System Configurations
    El-Nemr, Mohamed K.
    Omara, Ahmed M.
    PROCEEDINGS OF 2016 EIGHTEENTH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2016, : 877 - 882
  • [40] Single collective excitation of an atomic array trapped along a waveguide: A study of cooperative emission for different atomic chain configurations
    Pivovarov, V. A.
    Gerasimov, L., V
    Berroir, J.
    Ray, T.
    Laurat, J.
    Urvoy, A.
    Kupriyanov, D., V
    PHYSICAL REVIEW A, 2021, 103 (04)