Equivalent energy wave for long-term analysis of ground coupled heat exchangers

被引:14
|
作者
Abdelaziz, Sherif L. [1 ,2 ]
Olgun, C. Guney [1 ]
Martin, James R., II [1 ,3 ]
机构
[1] Virginia Tech, Charles E Via Dept Civil & Environm Engn, Blacksburg, VA 24061 USA
[2] CH2M HILL Inc, Chantilly, VA 20151 USA
[3] Clemson Univ, Glenn Dept Civil Engn, Clemson, SC 29634 USA
基金
美国国家科学基金会;
关键词
Geothermal; Energy pile; Heat exchanger; Long-term performance; UNKNOWN POINT;
D O I
10.1016/j.geothermics.2014.04.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a robust approach to develop ground thermal loads to be used for the long-term analysis of ground-coupled heat exchangers. The thermal loads developed using the proposed approach are simple, yet accounts for the hourly variation of the thermal loads. The analysis to develop these ground thermal loads is based on the change-point statistical analysis to determine the heating and cooling episodes. Heating and cooling loads are then converted into sine waves with an equivalent amplitude and the episodes determined from the change-point statistical analysis. Using the approximated equivalent sine waves, finite element or finite difference methods can be utilized to predict the long-term performance of the heat exchangers. The proposed methodology is compared to other existing approaches and showed better representation of the varying hourly ground thermal loads for a 1 year period. Moreover, a long-term thermal performance is predicted using the equivalent sine waves developed for balanced and unbalanced ground loads. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:67 / 84
页数:18
相关论文
共 50 条
  • [31] Long-Term Temperature Evaluation of a Ground-Coupled Heat Pump System Subject to Groundwater Flow
    Jaziri, Nehed
    Raymond, Jasmin
    Giordano, Nicolo
    Molson, John
    ENERGIES, 2020, 13 (01)
  • [32] Improving the performance of Ground Coupled Heat Exchangers in unsaturated soils
    Platts, Arnold B.
    Cameron, Don A.
    Ward, James
    ENERGY AND BUILDINGS, 2015, 104 : 323 - 335
  • [33] Long-term monitoring and performance of ground source heat pumps
    Stafford, A.
    BUILDING RESEARCH AND INFORMATION, 2011, 39 (06): : 566 - 573
  • [34] The ground surface energy balance in modelling horizontal ground heat exchangers
    Bortoloni, Marco
    Bottarelli, Michele
    Su, Yuehong
    34TH UIT HEAT TRANSFER CONFERENCE 2016, 2017, 796
  • [35] Study on a design method for hybrid ground heat exchangers of ground-coupled heat pump system
    Wei, Kejuan
    Li, Wenxin
    Li, Jiarong
    Wang, Yong
    Zhang, Lu
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 76 : 394 - 405
  • [36] ON SAMPLING BETWEEN DATA OF SIGNIFICANT WAVE HEIGHT FOR LONG-TERM ANALYSIS WITH EQUIVALENT TRIANGULAR STORM MODEL
    Arena, Felice
    Laface, Valentina
    PROCEEDINGS OF THE ASME 32ND INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING - 2013, VOL 2B, 2013,
  • [37] Heat transfer analysis of ground heat exchangers with inclined boreholes
    Cui, P
    Yang, HX
    Fang, ZH
    APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) : 1169 - 1175
  • [38] Heat transfer analysis of boreholes in vertical ground heat exchangers
    Zeng, HY
    Diao, NR
    Fang, ZH
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (23) : 4467 - 4481
  • [39] Can deep borehole heat exchangers operate stably in long-term operation? Simulation analysis and design method
    Deng, Jiewen
    Qiang, Wenbo
    Peng, Chenwei
    Wei, Qingpeng
    Cai, Wanlong
    Zhang, Hui
    JOURNAL OF BUILDING ENGINEERING, 2022, 62
  • [40] Short time step analysis of vertical ground-coupled heat exchangers: The approach of CaRM
    Zarrella, Angelo
    Scarpa, Massimiliano
    De Carli, Michele
    RENEWABLE ENERGY, 2011, 36 (09) : 2357 - 2367