COMPARISON BETWEEN TWO DIFFERENT MESH FIXATION METHODS IN LAPAROSCOPIC INGUINAL HERNIA REPAIR: TACKER VS. SYNTHETIC CYANOACRYLATE GLUE

被引:0
|
作者
Burza, A. [1 ]
Avantifiori, R. [1 ]
Curinga, R. [1 ]
Santini, E. [1 ]
Delle Site, P. [1 ]
Stipa, F. [1 ]
机构
[1] Azienda Osped S Giovanni Addolorata, Dipartimento Sci Chirurg, Unita Operat Chirurg Gen Colonproctol, I-00186 Rome, Italy
关键词
Hernia; inguinal; Herniorrhaphy; Surgical mesh; Cyanoacrylates; POLYPROPYLENE MESH; HEAVYWEIGHT MESH; FIBRIN SEALANT; PAIN; TRIAL; HERNIORRHAPHY; HERNIOPLASTY; SAFETY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aim. The aim of this retrospective study was to compare the results of two different mesh fixation methods in laparoscopic transabdominal preperitoneal hernioplasty (TAPP): tacker vs. synthetic cyanoacrylate glue. Methods. The study group includes 70 patients with bilateral and monolateral recurrent inguinal hernia undergoing transabdominal preperitoneal repair (TAPP) in the period 2011-2013. A polypropylene mesh was fixed in group A (N.=35) with titanium tacks (Endo Universal stapler, Covidien) or in group B (N.=35) with synthetic cyanoacrylate glue (Glubran-2, GEM). Patient outcome was assessed by the following variables: sex, mean age, ASA score, intra- and postoperative morbidity, hospitalization, postoperative acute and chronic pain, recurrence rate. The observation period was 24 months, with a mean follow-up of 10.5 months (range, 1-23) for Group A and 11 months (range, 2-24) for Group B. Results. No difference between the two groups was observed with respect to mean operative time and hospitalization. In all cases, surgery was successfully concluded laparoscopically. Intraoperative complications occurred in 1 patient of the group A and consisted of a urinary bladder injury, which was immediately sutured. Postoperative complication rate was 5.7% (4 patients, of whom 3 in group A and 1 in group B). In each group we detected one recurrence within 6 (group A) and 18 months (group B) postsurgery; both patients were treated with a re-TAPP. Postoperative pain at 6 months from surgery, measured by visual analogue score (VAS), was reported by 4 patients in the group A and in no case of the group B (P=0.04). Conclusion. Data from this study demonstrate the advantages of synthetic cyanoacrylate glue for mesh fixation in laparoscopic transabdominal preperitoneal inguinal hernia repair, compared to titanium tacks. The use of this surgical glue was associated with a significantly reduced risk for developing chronic groin pain and a shortened hospital stay. Nevertheless, further studies with longer follow-up periods are needed to confirm our encouraging results.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 50 条
  • [41] A meta-analysis comparing tacker mesh fixation with suture mesh fixation in laparoscopic incisional and ventral hernia repair
    Sajid, M. S.
    Parampalli, U.
    McFall, M. R.
    HERNIA, 2013, 17 (02) : 159 - 166
  • [42] Laparoscopic Transabdominal Preperitoneal (TAPP) Inguinal Hernia Repair Using Fibrin Glue for Fixation of the Mesh and Peritoneum Closure
    Ielpo, Benedetto
    Valentina, Ferri
    Silva, Jesus
    Quijano, Yolanda
    Vicente, Emilio
    Diago, Maria V.
    Caruso, Riccardo
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2020, 30 (04): : E24 - E27
  • [43] Fibrin glue versus tacked fixation of mesh in laparoscopic transabdominal preperitoneal repair of inguinal hernia: A prospective study
    Hassanin, Zeinab S.
    Elghamry, Elghamry E.
    Soliman, Soliman M.
    Elsheikh, Mohamed M.
    EGYPTIAN JOURNAL OF SURGERY, 2024, 43 (03): : 806 - 813
  • [44] Fibrin glue for securing the mesh in laparoscopic totally extraperitoneal inguinal hernia repair
    Novik, B
    Hagedorn, S
    Mörk, UB
    Dahlin, K
    Skullman, S
    Dalenbäck, J
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (03): : 462 - 467
  • [45] Comparison of self-gripping mesh with mesh fixation with fibrin-glue in laparoscopic hernia repair (TAPP)
    Cambal, M.
    Zonca, P.
    Hrbaty, B.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2012, 113 (02): : 103 - 107
  • [46] Comparison of anatomical polyester mesh without fixation and conventional flat mesh with fixation in laparoscopic total extraperitoneal repair for inguinal hernia
    Lee, Wei-Chang
    Huang, Ching-Wei
    Fan, Le-Wei
    Li, Yun-Ren
    Chang, Ying-Hsu
    Hsu, Yu-Chao
    Liu, Chung-Yi
    HERNIA, 2025, 29 (01)
  • [47] Comparison of fixed mesh and unfixed plica mesh methods in laparoscopic total extraperitoneal inguinal hernia repair
    Colak, Sukru
    Dal, Fatih
    Cakar, Ekrem
    Gurbulak, Bunyamin
    Bektas, Hasan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 14 (01): : 503 - 511
  • [48] Glue versus tackers for mesh fixation in laparoscopic inguinal hernia repair: a meta-analysis and trial sequential analysis
    Kitching, Samuel
    Patel, Agastya
    Tan, Jacob
    Kadamapuzah, Jacob
    Satyadas, Thomas
    HERNIA, 2025, 29 (01)
  • [49] Initial experience with the use of n-butyl 2-cyanoacrylate glue for the fixation of polypropylene mesh in laparoscopic hernia repair
    Jourdan, IC
    Bailey, ME
    SURGICAL LAPAROSCOPY & ENDOSCOPY, 1998, 8 (04) : 291 - 293
  • [50] Randomised controlled trial of n-butyl cyanoacrylate glue fixation versus suture fixation of mesh in laparoscopic totally extraperitoneal hernia repair
    Jani, Kalpesh
    JOURNAL OF MINIMAL ACCESS SURGERY, 2016, 12 (02) : 118 - 123