COMPARISON BETWEEN TWO DIFFERENT MESH FIXATION METHODS IN LAPAROSCOPIC INGUINAL HERNIA REPAIR: TACKER VS. SYNTHETIC CYANOACRYLATE GLUE

被引:0
|
作者
Burza, A. [1 ]
Avantifiori, R. [1 ]
Curinga, R. [1 ]
Santini, E. [1 ]
Delle Site, P. [1 ]
Stipa, F. [1 ]
机构
[1] Azienda Osped S Giovanni Addolorata, Dipartimento Sci Chirurg, Unita Operat Chirurg Gen Colonproctol, I-00186 Rome, Italy
关键词
Hernia; inguinal; Herniorrhaphy; Surgical mesh; Cyanoacrylates; POLYPROPYLENE MESH; HEAVYWEIGHT MESH; FIBRIN SEALANT; PAIN; TRIAL; HERNIORRHAPHY; HERNIOPLASTY; SAFETY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aim. The aim of this retrospective study was to compare the results of two different mesh fixation methods in laparoscopic transabdominal preperitoneal hernioplasty (TAPP): tacker vs. synthetic cyanoacrylate glue. Methods. The study group includes 70 patients with bilateral and monolateral recurrent inguinal hernia undergoing transabdominal preperitoneal repair (TAPP) in the period 2011-2013. A polypropylene mesh was fixed in group A (N.=35) with titanium tacks (Endo Universal stapler, Covidien) or in group B (N.=35) with synthetic cyanoacrylate glue (Glubran-2, GEM). Patient outcome was assessed by the following variables: sex, mean age, ASA score, intra- and postoperative morbidity, hospitalization, postoperative acute and chronic pain, recurrence rate. The observation period was 24 months, with a mean follow-up of 10.5 months (range, 1-23) for Group A and 11 months (range, 2-24) for Group B. Results. No difference between the two groups was observed with respect to mean operative time and hospitalization. In all cases, surgery was successfully concluded laparoscopically. Intraoperative complications occurred in 1 patient of the group A and consisted of a urinary bladder injury, which was immediately sutured. Postoperative complication rate was 5.7% (4 patients, of whom 3 in group A and 1 in group B). In each group we detected one recurrence within 6 (group A) and 18 months (group B) postsurgery; both patients were treated with a re-TAPP. Postoperative pain at 6 months from surgery, measured by visual analogue score (VAS), was reported by 4 patients in the group A and in no case of the group B (P=0.04). Conclusion. Data from this study demonstrate the advantages of synthetic cyanoacrylate glue for mesh fixation in laparoscopic transabdominal preperitoneal inguinal hernia repair, compared to titanium tacks. The use of this surgical glue was associated with a significantly reduced risk for developing chronic groin pain and a shortened hospital stay. Nevertheless, further studies with longer follow-up periods are needed to confirm our encouraging results.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 50 条
  • [1] Comparison of the Clinical Outcome and Complications in Laparoscopic Hernia Repair of Inguinal Hernia With Mesh Fixation Using Fibrin Glue vs Tacker
    Chandra, Prasant
    Phalgune, Deepak
    Shah, Shashank
    INDIAN JOURNAL OF SURGERY, 2016, 78 (06) : 464 - 470
  • [2] Comparison of the Clinical Outcome and Complications in Laparoscopic Hernia Repair of Inguinal Hernia With Mesh Fixation Using Fibrin Glue vs Tacker
    Prasant Chandra
    Deepak Phalgune
    Shashank Shah
    Indian Journal of Surgery, 2016, 78 : 464 - 470
  • [3] Mesh fixation with fibrin glue versus tacker in laparoscopic totally extraperitoneal inguinal hernia repair
    Nizam, Saifullah
    Saxena, Neeraj
    Yelamanchi, Raghav
    Sana, Sana
    Kardam, Dinesh
    ANZ JOURNAL OF SURGERY, 2021, 91 (10) : 2086 - 2090
  • [4] A meta-analysis examining the use of tacker mesh fixation versus glue mesh fixation in laparoscopic inguinal hernia repair
    Sajid, Muhammad S.
    Ladwa, Nikhil
    Kalra, Lorain
    McFall, Malcolm
    Baig, Mirza K.
    Sains, Parv
    AMERICAN JOURNAL OF SURGERY, 2013, 206 (01): : 103 - 111
  • [5] Cyanoacrylate glue mesh fixation versus suture mesh fixation in Lichtenstein inguinal hernia repair
    Arafa, Ahmed Salah
    Khairy, Mostafa Mohamed
    Rushdy, Tamer
    Gomaa, Mohammad Alsayed
    EGYPTIAN JOURNAL OF SURGERY, 2019, 38 (03): : 471 - 477
  • [6] Tacker fixation versus fibrin glue fixation of mesh in laparoscopic inguinal hernia repair: A systematic review and meta-analysis
    Sajid, M. S.
    Ladwa, N.
    Sains, P.
    Baig, M. K.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 154 - 154
  • [7] Cyanoacrylate Surgical Glue for Mesh Fixation in Laparoscopic Total Extraperitoneal Hernia Repair
    Garcia-Vallejo, Luis
    Couto-Gonzalez, Ivan
    Concheiro-Coello, Pablo
    Brea-Garcia, Beatriz
    Taboada-Suarez, Antonio
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2014, 24 (03): : 240 - 243
  • [8] Comparison between fibrin glue versus mechanical mesh fixation in laparoscopic inguinal hernia repair: A prospective study
    Emad, Moustafa M.
    Wakim, Hany R.
    Ali, Mahmoud A.
    Fawzy, Fawzy S.
    EGYPTIAN JOURNAL OF SURGERY, 2025, 44 (01): : 79 - 85
  • [9] Cyanoacrylate Glue Versus Absorbable Tacks in Mesh Fixation for Laparoscopic Extraperitoneal Inguinal Hernia Repair: A Randomized Controlled Trial
    Issa, Michael
    Tacey, Mark
    Geraghty, Joshua
    Das, Atandrila
    Dhir, Arun
    Mori, Krinal
    To, Henry
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2021, 31 (03): : 291 - 297
  • [10] Comparison of post-operative pain after laparoscopic total extraperitoneal mesh repair of indirect inguinal hernia with tacker and without tacker fixation
    Hussain, Shahid
    Shabbir, Asiya
    Asif, Muhammad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (10): : 2733 - 2735