Performance Testing of a Venturi-Based Backpack Spray Decontamination System

被引:1
|
作者
Beswick, Alan [1 ]
Bailey, Claire [1 ]
Crook, Brian [1 ]
Crouch, David [2 ]
Farrant, Jayne [1 ]
Frost, Gillian [1 ]
Stagg, Stephen [1 ]
机构
[1] Hlth & Safety Execut, Harpur Hill, Buxton SK17 9JN, Derby, England
[2] 3MTM United Kingdom PLC, Skelmersdale, Lancs, England
关键词
peracetic acid; hypochlorous acid; atomization; decontamination; venturi lance; biosecurity;
D O I
10.1177/1535676019898299
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction: The performance of 2 disinfectant chemicals, peracetic acid (PAA) and hypochlorous acid (HOCl), was evaluated using a Venturi-nozzle-based light decontamination system (LDS) for delivery. The atomization equipment combined low-pressure air and disinfectant via a handheld lance, producing a fine, dense aerosol. A range of microorganisms, including Bacillus cereus and Bacillus anthracis (Vollum) spores, were used as test challenges to evaluate chemicals and equipment. Methods: The tests undertaken included assessments over fixed and variable exposure times, use of multiple surface materials, and a live agent challenge. Results: Over a fixed-time exposure of 60 minutes, aerosolized PAA gave 7- to 8-log reductions of all test challenges, but HOCl was less effective. Material tests showed extensive kill on most surfaces using PAA (>= 6-log kill), but HOCl showed more variation (4- to 6-log). Testing using B. anthracis showed measurable PAA induced spore kill inside 5 minutes and >6-log kill at 5 minutes or over. HOCl was less effective. Discussion: The results demonstrate the importance of testing decontamination systems against a range of relevant microbiological challenges. Disinfectant efficacy may vary depending on product choice, types of challenge microorganisms, and their position in a treated area. The most effective disinfectants demonstrate biocidal efficacy despite these factors. Conclusion: The data confirmed PAA as an effective disinfectant capable of rapidly killing a range of microorganisms, including spores. HOCl was less effective. The LDS system successfully delivered PAA and HOCl over a wide area and could be suitable for a range of frontline biosecurity applications.
引用
收藏
页码:28 / 40
页数:13
相关论文
共 50 条
  • [41] Evaluation of an Ethanol-Based Spray Disinfectant for Decontamination of Cover Gowns Prior to Removal
    Koganti, Sreelatha
    Alhmidi, Heba
    Tomas, Myreen E.
    Cadnum, Jennifer L.
    Sass, Christopher
    Jencson, Annette L.
    Donskey, Curtis J.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2017, 38 (03): : 364 - 366
  • [42] Performance evaluation of venturi scrubber for the removal of iodine in filtered containment venting system
    Bal, Manisha
    Reddy, Thamatam Tejaswini
    Melkap, B. C.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 138 : 158 - 167
  • [43] Maximize the performance of your spray nozzle system
    Pagcatipunan, C
    Schick, R
    CHEMICAL ENGINEERING PROGRESS, 2005, 101 (12) : 38 - 44
  • [44] Transient characteristics and performance of a novel desalination system based on heat storage and spray flashing
    Miyatake, O
    Koito, Y
    Tagawa, K
    Maruta, Y
    DESALINATION, 2001, 137 (1-3) : 157 - 166
  • [45] ANALYSIS OF FACTORS INFLUENCING HEAT TRANSFER PERFORMANCE BASED ON SHIP SPRAY COOLING SYSTEM
    Wang, Yujiao
    Huang, Long
    THERMAL SCIENCE, 2024, 28 (1A): : 333 - 345
  • [46] Study on cooling performance of rapid cooling system based on vacuum spray flash evaporation
    Fu, Hao
    Zhao, Rui
    Long, Wenjun
    Cheng, Wenlong
    APPLIED THERMAL ENGINEERING, 2022, 201
  • [47] AIRCRAFT SPRAY SYSTEM PERFORMANCE USING SOYBEAN OIL AS SPRAY DILUENT.
    Whitney, R.W.
    Kuhlman, D.K.
    Roth, L.O.
    Transactions of the American Society of Agricultural Engineers, 1985, 28 (03): : 665 - 668
  • [48] Design of Performance Testing System for HVAC Based on Enthalpy Difference Method
    Du, Guangyue
    Zhou, Shiyu
    Zhou, Yucheng
    Liu, Xiaoping
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2156 - 2163
  • [49] TESTING AND OPTIMIZING THE PERFORMANCE OF A FLOOR-BASED TASK CONDITIONING SYSTEM
    BAUMAN, FS
    ARENS, EA
    TANABE, S
    ZHANG, H
    BAHARLO, A
    ENERGY AND BUILDINGS, 1995, 22 (03) : 173 - 186
  • [50] VRML-based Laboratory System for Material Mechanical Performance Testing
    Tang, Jia-li
    Wu, Fang-sheng
    2010 2ND INTERNATIONAL ASIA CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS (CAR 2010), VOL 1, 2010, : 202 - 205