Low-picomolar, label-free procalcitonin analytical detection with an electrolyte-gated organic field-effect transistor based electronic immunosensor

被引:89
|
作者
Seshadri, Preethi [1 ]
Manoli, Kyriaki [1 ]
Schneiderhan-Marra, Nicole [2 ]
Anthes, Uwe [3 ]
Wierzchowiec, Piotr [3 ]
Bonrad, Klaus [3 ]
Di Franco, Cinzia [4 ]
Torsi, Luisa [1 ,5 ]
机构
[1] Univ Bari A Moro, Dipartimento Chim, Via Orabona 4, I-70125 Bari, Italy
[2] Univ Tubingen, Nat & Med Sci Inst NMI, Markwiesenstr 55, D-72770 Reutlingen, Germany
[3] Merck KGaA, Frankfurter Str 250, D-64271 Darmstadt, Germany
[4] CNR, Ist Foton & Nanotecnol, Sede Bari, Bari, Italy
[5] Abo Akad Univ, Fac Sci & Engn, Biskopsgatan 8 Abo, SF-20500 Turku, Finland
来源
关键词
Electrolyte-gated organic field-effect transistors; Immunosensor; Procalcitonin; Label-free detection; POINT; SENSORS; ANTIBODIES; BIOSENSOR;
D O I
10.1016/j.bios.2017.12.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Herein a label-free immunosensor based on electrolyte-gated organic field-effect transistor (EGOFET) was developed for the detection of procalcitonin (PCT), a sepsis marker. Antibodies specific to PCT were immobilized on the poly-3-hexylthiophene (P3HT) organic semiconductor surface through direct physical adsorption followed by a post-treatment with bovine serum albumin (BSA) which served as the blocking agent to prevent nonspecific adsorption. Antibodies together with BSA (forming the whole biorecognition layer) served to selectively capture the procalcitonin target analyte. The entire immunosensor fabrication process was fast, requiring overall 45 min to be completed before analyte sensing. The EGOFET immunosensor showed excellent electrical properties, comparable to those of bare P3HT based EGOFET confirming reliable biosensing with bio-functional EGOFET immunosensor. The detection limit of the immunosensor was as low as 2.2 pM and within a range of clinical relevance. The relative standard deviation of the individual calibration data points, measured on immunosensors fabricated on different chips (reproducibility error) was below 7%. The developed immunosensor showed high selectivity to the PCT analyte which was evident through control experiments. This report of PCT detection is first of its kind among the electronic sensors based on EGOFETs. The developed sensor is versatile and compatible with low-cost fabrication techniques.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 50 条
  • [21] Organic field-effect transistor for label-free dopamine sensing
    Casalini, Stefano
    Leonardi, Francesca
    Cramer, Tobias
    Biscarini, Fabio
    ORGANIC ELECTRONICS, 2013, 14 (01) : 156 - 163
  • [22] An Electrolyte-Gated Graphene Field-Effect Transistor for Detection of Gadolinium(III) in Aqueous Media
    Gadroy, Charlene
    Boukraa, Rassen
    Battaglini, Nicolas
    Le Derf, Franck
    Mofaddel, Nadine
    Vieillard, Julien
    Piro, Benoit
    BIOSENSORS-BASEL, 2023, 13 (03):
  • [23] Label-Free Sub-picomolar Protein Detection with Field-Effect Transistors
    Estrela, Pedro
    Paul, Debjani
    Song, Qifeng
    Stadler, Lukas K. J.
    Wang, Ling
    Huq, Ejaz
    Davis, Jason J.
    Ferrigno, Paul Ko
    Migliorato, Piero
    ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3531 - 3536
  • [24] Stability evaluation and gate-distance effects on electrolyte-gated organic field-effect transistor based on organic semiconductors
    Mello, H. J. N. P. D.
    Dalgleish, S.
    Ligorio, G.
    Mulato, M.
    List-Kratochvil, E. J. W.
    ORGANIC AND HYBRID SENSORS AND BIOELECTRONICS XI, 2018, 10738
  • [25] Exploiting ionic coupling in electronic devices: Electrolyte-gated organic field-effect transistors
    Panzer, Matthew J.
    Frisbie, C. Daniel
    ADVANCED MATERIALS, 2008, 20 (16) : 3177 - 3180
  • [26] Hydrogen ion-selective electrolyte-gated organic field-effect transistor for pH sensing
    Kofler, Johannes
    Schmoltner, Kerstin
    Klug, Andreas
    List-Kratochvil, Emil J. W.
    APPLIED PHYSICS LETTERS, 2014, 104 (19)
  • [27] The Substrate is a pH-Controlled Second Gate of Electrolyte-Gated Organic Field-Effect Transistor
    Di Lauro, Michele
    Casalini, Stefano
    Berto, Marcello
    Campana, Alessandra
    Cramer, Tobias
    Murgia, Mauro
    Geoghegan, Mark
    Bortolotti, Carlo A.
    Biscarini, Fabio
    ACS Applied Materials & Interfaces, 2016, 8 (46) : 31783 - 31790
  • [28] Advances in organic transistor-based biosensors: from organic electrochemical transistors to electrolyte-gated organic field-effect transistors
    Loïg Kergoat
    Benoît Piro
    Magnus Berggren
    Gilles Horowitz
    Minh-Chau Pham
    Analytical and Bioanalytical Chemistry, 2012, 402 : 1813 - 1826
  • [29] Versatile transduction scheme based on electrolyte-gated organic field-effect transistor used as immunoassay readout system
    Piro, Benoit
    Wang, Dengjun
    Benaoudia, Dihia
    Tibaldi, Alexandra
    Anquetin, Guillaume
    Noel, Vincent
    Reisberg, Steeve
    Mattana, Giorgio
    Jackson, Brianna
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 215 - 220
  • [30] Advances in organic transistor-based biosensors: from organic electrochemical transistors to electrolyte-gated organic field-effect transistors
    Kergoat, Loig
    Piro, Benoit
    Berggren, Magnus
    Horowitz, Gilles
    Minh-Chau Pham
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (05) : 1813 - 1826