Changes in the molecular composition of crude oils during their preparation for GC and GC-MS analyses

被引:67
|
作者
Ahmed, M [1 ]
George, SC [1 ]
机构
[1] CSIRO Petr, N Ryde, NSW 1670, Australia
关键词
D O I
10.1016/j.orggeochem.2003.10.002
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Rotary evaporation and nitrogen blowing are the two frequently used procedures in organic geochemistry laboratories to prepare crude oils and extractable organic matter for gas chromatography (GC) and GC-mass spectrometry (GC-MS) analyses. In this work, the effects of these preparatory procedures on the molecular composition have been comprehensively assessed for the first time, by evaporating 34 aliquots of North Sea Oil-1 dissolved in dichloromethane under a variety of conditions: (a) rotary evaporation with a reduced pressure of 80 to 60 kpa, and water bath temperatures of 30-60 degreesC, (b) nitrogen blowing, with flow rates of 130 to > 850 ml/min and heater block temperatures of 30-60 C, and (c) open vial evaporation in a refrigerator at 3 C and in a fume cupboard at 22 C. Analyses of the unaltered original oil solution and the evaporated oil aliquots for 215 target compounds, from benzene to n-C-32, indicate that (1)<n-C-15 compounds are very susceptible to all the evaporation procedures applied, (2) the loss of variable amounts of <n-C-12 compounds is almost inevitable, and (3) rotary evaporation is less destructive to compound distributions than nitrogen blowing. During rotary evaporation, the extent of compound loss depends on water bath temperature, the amount of solvent reduction, the level of reduced pressure and the length of drying. During nitrogen blowing the extent of compound loss depends on the heater block temperature, the amount of solvent reduction and the length of drying. If a sample is blown to dryness, higher nitrogen flow rates also cause more loss. The extent of compound loss generally increases with decreasing boiling points and molecular weights. However, some compounds such as C-0-C-2 alkylbenzenes do not follow this trend and are particularly resistant to laboratory evaporation processes. Nitrogen blowing evaporation to dryness can result in substantial losses of <C-21 n-alkanes, alkylnaphthalenes, methylbiphenyls, methyldibenzothiophenes and methylphenanthrenes, and their non-alkylated parents. The Pr/Ph, Pr/n-C-17, methylnaphthalene and dimethylnaphthalene ratios are reduced if evaporation is particularly severe, whilst the methylbiphenyl ratio is increased by evaporation. Despite overall loss of trimethylnaphthalenes, tetramethylnaphthalenes, methylphenanthrenes and methyldibenzothiophenes during evaporation, ratios based on these compounds appear to be unaffected by the extent of evaporation. Light (<n-C-9) hydrocarbon distributions and their ratios are severely altered by any evaporation, suggesting the requirement of special care in sample handling and data interpretations. The evaporated oil aliquots, like the residual oils formed by natural evaporative fractionation, exhibit an increase in the aromatic hydrocarbons relative to normal alkanes, an increase in normal alkanes relative to branched alkanes, and a decrease in linear alkanes relative to cyclic alkanes. Crown Copyright (C) 2003 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:137 / 155
页数:19
相关论文
共 50 条
  • [31] GC-MS GC-MS/MS AND GC-IR STUDIES ON SUBSTITUTED CATHINONE DESIGNER DRUGS
    Clark, C. Randall
    Deruiter, Jack
    Abiedalla, Younis
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 75 - 75
  • [32] BIOMARKERS IN TERRESTRIALLY DERIVED CRUDE OILS FROM AUSTRALIA AND NEW-ZEALAND AS DETERMINED BY GC-MS AND MS/MS
    PHILP, RP
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 82 - GEOC
  • [33] Composition of commercial truffle flavored oils with GC-MS analysis and discrimination with an electronic nose
    Pacioni, Giovanni
    Cerretani, Lorenzo
    Procida, Giuseppe
    Cichelli, Angelo
    [J]. FOOD CHEMISTRY, 2014, 146 : 30 - 35
  • [34] GC-MS analysis of two types of mixed oils, a comparison of composition and weathering patterns
    Ho, S. J.
    Wang, C. Y.
    Luo, Y. M.
    [J]. MARINE POLLUTION BULLETIN, 2015, 96 (1-2) : 271 - 278
  • [35] Transcriptomic and GC-MS Metabolomic Analyses Reveal the Sink Strength Changes during Petunia Anther Development
    Yue, Yuanzheng
    Tian, Shaoze
    Wang, Yu
    Ma, Hui
    Liu, Siyu
    Wang, Yuqiao
    Hu, Huirong
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (04)
  • [36] Extraction and derivatization of polar herbicides for GC-MS analyses
    Ranz, Andreas
    Maier, Eveline
    Motter, Herbert
    Lankmayr, Ernst
    [J]. JOURNAL OF SEPARATION SCIENCE, 2008, 31 (16-17) : 3021 - 3029
  • [37] AUTOMATED EVALUATION OF GC-MS ANALYSES OF CHLORINATED PHENOLS
    JURASEK, P
    BREZNY, R
    KOSIK, M
    [J]. CHEMICAL PAPERS, 1992, 46 (03): : 184 - 188
  • [38] Fast GC-MS in supersonic molecular beams
    Amirav, A
    Dagan, S
    [J]. ISRAEL JOURNAL OF CHEMISTRY, 1997, 37 (04) : 475 - 482
  • [39] IDENTIFICATION OF IMPURITIES IN CRUDE TNT BY TANDEM GC-MS TECHNIQUE
    CHANG, TL
    [J]. ANALYTICA CHIMICA ACTA, 1971, 53 (02) : 445 - &
  • [40] Pyrolysis GC-MS
    Geissler, M
    [J]. KUNSTSTOFFE-PLAST EUROPE, 1997, 87 (02): : 194 - 196