Instantaneous measurement of M2 beam propagation ratio in real-time

被引:8
|
作者
Cary, Allen M. [1 ]
Guttman, Jeffrey L. [1 ]
Chirita, Razvan [1 ]
Peterman, Derrick W. [1 ]
机构
[1] Photon Inc, San Jose, CA 95119 USA
关键词
D O I
10.1117/12.763661
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new instrument design allows the M-2 beam propagation ratio to be measured in real time at the update rate of a standard CCD camera. This allows lasers from single shot to CW to be measured while the laser cavities are being adjusted. This drastically reduces the test time required for this operation. In this paper we will discuss the theory behind this innovative approach to the M-2 measurement and the methods for the selection of the proper optical components for use of the system with various laser types and beam shapes. The authors will show results of numerous measurements of different lasers and laser types, including solid state diode and traditional gas lasers with M-2 Values from near 1 to considerably higher values, and show comparisons these results with other measurement methods. The instrument design is based on a method of simultaneous capture of the waist and several Rayleigh ranges, allowing the instantaneous fit of the ISO M-2 propagation curve. The authors will discuss the important considerations necessary to generate accurate results for different laser configurations.
引用
收藏
页码:87103 / 87103
页数:11
相关论文
共 50 条
  • [41] AN EMPHASIS ON REAL-TIME MEASUREMENT
    不详
    MANUFACTURING ENGINEERING, 1982, 89 (05): : 34 - 35
  • [42] MEASUREMENT OF POISSON RATIO USING REAL-TIME DIGITAL SPECKLE PATTERN INTERFEROMETRY
    GANESAN, AR
    OPTICS AND LASERS IN ENGINEERING, 1989, 11 (04) : 265 - 269
  • [43] Monte Carlo Least-Squares Fitting of the Beam Propagation Factor M2
    Alsous, M. B.
    Almezel, M.
    Alnezami, M.
    ACTA PHYSICA POLONICA A, 2013, 124 (04) : 673 - 676
  • [44] Strain ratio measurement of femoral cartilage by real-time elastosonography: preliminary results
    Nurdan Cay
    Ali Ipek
    Cetin Isik
    Ozlem Unal
    Merve Gulbiz Kartal
    Halil Arslan
    Murat Bozkurt
    European Radiology, 2015, 25 : 987 - 993
  • [45] Strain ratio measurement of femoral cartilage by real-time elastosonography: preliminary results
    Cay, Nurdan
    Ipek, Ali
    Isik, Cetin
    Unal, Ozlem
    Kartal, Merve Gulbiz
    Arslan, Halil
    Bozkurt, Murat
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 987 - 993
  • [46] Real-time temperature measurement
    Atlas Material Testing Technology LLC, Chicago, IL
    不详
    Finsh. Today, 2008, 2 (28-31):
  • [47] Collective intelligence ratio Measurement of real-time multimodal interactions in team projects
    Kim, Paul
    Lee, Donghwan
    Lee, Youngjo
    Huang, Chuan
    Makany, Tamas
    TEAM PERFORMANCE MANAGEMENT, 2011, 17 (1-2) : 41 - +
  • [48] Development of a Rapid Beam Emittance Measurement System using a Real-Time Beam Profile Monitor
    Kamakura, Keita
    Hatanaka, Kichiji
    Fukuda, Mitsuhiro
    Yorita, Tetsuhiko
    Ueda, Hiroshi
    Saito, Takane
    Morinobu, Shunpei
    Nagayama, Keiichi
    Tamura, Hitoshi
    Yasuda, Yuusuke
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1710 - 1714
  • [49] Development of a Rapid Beam Emittance Measurement System using a Real-Time Beam Profile Monitor
    Kamakura, Keita
    Hatanaka, Kichiji
    Fukuda, Mitsuhiro
    Yorita, Tetsuhiko
    Ueda, Hiroshi
    Saito, Takane
    Morinobu, Shunpei
    Nagayama, Keiichi
    Tamura, Hitoshi
    Yasuda, Yuusuke
    2014 19TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2014,
  • [50] Measurement of beam quality factor (M2) by slit-scanning method
    Zheng, J
    Zhao, SZ
    Wang, QP
    Zhang, XY
    Chen, L
    OPTICS AND LASER TECHNOLOGY, 2001, 33 (04): : 213 - 217