Instantaneous measurement of M2 beam propagation ratio in real-time

被引:8
|
作者
Cary, Allen M. [1 ]
Guttman, Jeffrey L. [1 ]
Chirita, Razvan [1 ]
Peterman, Derrick W. [1 ]
机构
[1] Photon Inc, San Jose, CA 95119 USA
关键词
D O I
10.1117/12.763661
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new instrument design allows the M-2 beam propagation ratio to be measured in real time at the update rate of a standard CCD camera. This allows lasers from single shot to CW to be measured while the laser cavities are being adjusted. This drastically reduces the test time required for this operation. In this paper we will discuss the theory behind this innovative approach to the M-2 measurement and the methods for the selection of the proper optical components for use of the system with various laser types and beam shapes. The authors will show results of numerous measurements of different lasers and laser types, including solid state diode and traditional gas lasers with M-2 Values from near 1 to considerably higher values, and show comparisons these results with other measurement methods. The instrument design is based on a method of simultaneous capture of the waist and several Rayleigh ranges, allowing the instantaneous fit of the ISO M-2 propagation curve. The authors will discuss the important considerations necessary to generate accurate results for different laser configurations.
引用
收藏
页码:87103 / 87103
页数:11
相关论文
共 50 条
  • [1] Influences on the beam propagation ratio M2
    Neubert, BJ
    Eppich, B
    OPTICS COMMUNICATIONS, 2005, 250 (4-6) : 241 - 251
  • [2] Evolution of a real-time laser M2 measurement system
    Scaggs, Michael
    Haas, Gilbert
    OPTICAL ENGINEERING, 2025, 64 (01)
  • [3] Real-time complex amplitude reconstruction method for beam quality M2 factor measurement
    Pan, Shaohua
    Ma, Jun
    Zhu, Rihong
    Ba, Tu
    Zuo, Chao
    Chen, Fan
    Dou, Jiantai
    Wei, Cong
    Zhou, Wenchao
    OPTICS EXPRESS, 2017, 25 (17): : 20142 - 20155
  • [4] Traceable measurements for beam propagation ratio M2
    Hall, S. R. G.
    Knox, S. D.
    THIRD INTERNATIONAL CONFERENCE ON OPTICAL AND LASER DIAGNOSTICS (ICOLAD 2007), 2007, 85
  • [5] Real-time measurement of laser beam quality factor (M2) by imaging transverse scattered light
    Jorge, Kelly Cristina
    Riva, Rudimar
    Silveira Rodrigues, Nicolau Andre
    Destro, Marcelo G.
    Laser Resonators and Beam Control IX, 2007, 6452 : 45215 - 45215
  • [6] Single shot M2 measurement for near infrared laser pulses in real-time
    Nagisetty, Siva Sankar
    Chyla, Michal
    Smrz, Martin
    Mocek, Tomas
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2019,
  • [7] Definition and measurement of the beam propagation factor M2 for chromatic laser beams
    房滔
    叶訢
    牛金富
    徐剑秋
    ChineseOpticsLetters, 2006, (10) : 586 - 588
  • [8] Definition and measurement of the beam propagation factor M2 for chromatic laser beams
    Shanghai Institute of Optics and Fine Mechanics, Chinese Acad. of Sci., Shanghai 201800, China
    Chin. Opt. Lett., 2006, 10 (586-588):
  • [9] Propagation characteristics of a diffracted M2 beam
    Amano, S
    Mochizuki, T
    APPLIED OPTICS, 2002, 41 (30) : 6325 - 6331
  • [10] Influences of CCD nonlinear response on measurement of propagation factor M2 of a laser beam
    Wang, You
    Kan, Hirofumi
    JOURNAL OF OPTICS, 2011, 13 (01)