Sensitivity and Specificity of CD19.CAR-T Cell Detection by Flow Cytometry and PCR

被引:26
|
作者
Schanda, Nicola [1 ]
Sauer, Tim [1 ]
Kunz, Alexander [1 ]
Huckelhoven-Krauss, Angela [1 ]
Neuber, Brigitte [1 ]
Wang, Lei [1 ]
Hinkelbein, Mandy [1 ]
Sedloev, David [1 ]
He, Bailin [1 ]
Schubert, Maria-Luisa [1 ]
Muller-Tidow, Carsten [1 ]
Schmitt, Michael [1 ]
Schmitt, Anita [1 ]
机构
[1] Univ Hosp Heidelberg, Dept Internal Med Hematol Oncol & Rheumatol 5, D-69120 Heidelberg, Germany
关键词
CD19; CAR-T cells; flow cytometry (FACS); polymerase chain reaction (PCR); detection reagent; CAR T-CELLS; ANTIGEN; STRATEGIES; LYMPHOMA; SAFETY;
D O I
10.3390/cells10113208
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Chimeric-antigen-receptor-T (CAR-T) cells are currently revolutionizing the field of cancer immunotherapy. Therefore, there is an urgent need for CAR-T cell monitoring by clinicians to assess cell expansion and persistence in patients. CAR-T cell manufacturers and researchers need to evaluate transduction efficiency and vector copy number for quality control. Here, CAR expression was analyzed in peripheral blood samples from patients and healthy donors by flow cytometry with four commercially available detection reagents and on the gene level by quantitative polymerase chain reaction (qPCR). Flow cytometric analysis of CAR expression showed higher mean CAR expression values for CD19 CAR detection reagent and the F(ab')2 antibody than Protein L and CD19 Protein. In addition, the CD19 CAR detection reagent showed a significantly lower median background staining of 0.02% (range 0.007-0.06%) when compared to the F(ab')2 antibody, CD19 protein and Protein L with 0.80% (range 0.47-1.58%), 0.65% (range 0.25-1.35%) and 0.73% (range 0.44-1.23%). Furthermore, flow cytometry-based CAR-T cell frequencies by CD19 CAR detection reagent showed a good correlation with qPCR results. In conclusion, quality control of CAR-T cell products can be performed by FACS and qPCR. For the monitoring of CAR-T cell frequencies by FACS in patients, CAR detection reagents with a low background staining are preferable.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Advanced Flow Cytometry Assays for Immune Monitoring of CAR-T Cell Applications
    Blache, Ulrich
    Weiss, Ronald
    Boldt, Andreas
    Kapinsky, Michael
    Blaudszun, Andre-Rene
    Quaiser, Andrea
    Pohl, Annabelle
    Miloud, Tewfik
    Burgaud, Megane
    Vucinic, Vladan
    Platzbecker, Uwe
    Sack, Ulrich
    Fricke, Stephan
    Koehl, Ulrike
    FRONTIERS IN IMMUNOLOGY, 2021, 12
  • [32] Balancing specificity and sensitivity in the detection of T-cell receptor-gamma gene rearrangements by multiplex PCR.
    Thackston, MD
    Rohlfs, EM
    Sirko-Osadsa, DA
    Garces, JA
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05): : 665 - 665
  • [33] Early Detection of Tonic Signaling in Primary Human CAR-T Cells by Flow Cytometry
    Nguyen, John
    MOLECULAR THERAPY, 2023, 31 (04) : 387 - 387
  • [34] RE-Treatment with CD19-Targeted CAR-T Cells for Relapse after CD19-CAR-T Cell Therapy
    Nishio, Nobuhiro
    Hamada, Motoharu
    Nishikawa, Eri
    Kawashima, Nozomu
    Narita, Atsushi
    Muramatsu, Hideki
    Wang, Kai
    Zheng, Huyong
    Chang, Jung-Li
    Takahashi, Yoshiyuki
    PEDIATRIC BLOOD & CANCER, 2021, 68
  • [35] Optimization and validation of in vivo flow cytometry chimeric antigen receptor T cell detection method using CD19his indirect staining
    Zaninelli, Silvia
    Meli, Cristian
    Borleri, Gianmaria
    Quaroni, Michele
    Pavoni, Chiara
    Gaipa, Giuseppe
    Biondi, Andrea
    Introna, Martino
    Golay, Josee
    Rambaldi, Alessandro
    Rambaldi, Benedetta
    CYTOMETRY PART A, 2024, 105 (02) : 112 - 123
  • [36] Regulatory T-Cell Detection by Flow Cytometry and Systemic Sclerosis
    Khan, Sujoy
    CTS-CLINICAL AND TRANSLATIONAL SCIENCE, 2011, 4 (01): : 72 - 72
  • [37] Novel CD19 Expression in a Peripheral T Cell Lymphoma: A Flow Cytometry Case Report with Morphologic Correlation
    Rizzo, Kathryn
    Stetler-Stevenson, Maryalice
    Wilson, Wyndham
    Yuan, Constance M.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (02) : 142 - 149
  • [38] Comparison of microcapillary cytometry technology and flow cytometry for CD4+ and CD8+ T-cell estimation
    Kandathil, AJ
    Kannangai, R
    David, S
    Nithyanandam, G
    Solomon, S
    Balakrishnan, P
    Abraham, OC
    Subramanian, S
    Rupali, P
    Verghese, VP
    Pulimood, S
    Sridharan, G
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (08) : 1006 - 1009
  • [39] EVALUATION OF ANTI-CD19 CAR-T CELL PERSISTENCE AND EFFICACY USING A DEVELOPED MULTIPARAMETRIC FLOW CYTOMETRY AND QPCR TRACKING PLATFORM FOR PRECLINICAL AND CLINICAL STUDIES
    Batista, L. C.
    Brand, H.
    Fantacini, D. M. C.
    Covas, D. T.
    Souza, L. E. B.
    CYTOTHERAPY, 2021, 23 (04) : 13 - 14
  • [40] Ex vivo phenotyping and potency monitoring of CD19 CAR T cells with a combined flow cytometry and impedance-based real time cell analysis workflow
    Zhao, Li
    Lei, Ming
    Ye, Peifang
    Lu, Yan
    Ji, Xiaoping
    Yan, Yu
    Jachimowicz, Lauren
    Guenther, Garret
    Li, Nancy
    CANCER RESEARCH, 2020, 80 (16)