Comparative investigation of two-dimensional imaging methods and X-ray tomography in the characterization of microstructure

被引:11
|
作者
Bacaicoa, Inigo [1 ,2 ]
Luetje, Martin [3 ]
Saelzer, Philipp [5 ]
Umbach, Cristin [4 ]
Brueckner-Foit, Angelika [6 ,7 ,8 ,9 ]
Heim, Hans-Peter [10 ,11 ]
Middendorf, Bernhard [12 ,13 ,14 ]
机构
[1] ITP, Aerosp Ind, Dept Mat & Special Proc, Zamudio, Spain
[2] Univ Kassel, Inst Mat Engn Qual & Reliabil, Field Casting Defects & Heat Treatment Optimizat, Kassel, Germany
[3] Univ Kassel, Inst Mat Engn Qual & Reliabil, Field Xray Tomog & Casting Defects Alloys, Kassel, Germany
[4] Univ Kassel, Dept Bldg Mats & Construct Chem, Inst Struct Engn, Kassel, Germany
[5] Univ Kassel, Dept Polymer Engn, Kassel, Germany
[6] Karlsruhe Res Ctr, Inst Mate Res 2, Dept Stochast, Karlsruhe, Germany
[7] Florida Atlantic Univ, Ctr Appl Stochast Res, Boca Raton, FL 33431 USA
[8] Univ Karlsruhe, Mech Engn Dept, Inst Reliabil & Damage, Karlsruhe, Germany
[9] Univ Kassel, Inst Mat Engn, Dept Qual & Reliabil, Kassel, Germany
[10] Univ Paderborn, Inst Plast Technol, Paderborn, Germany
[11] Univ Kassel, Plast Engin, Kassel, Germany
[12] Univ Kassel, Kassel, Germany
[13] TU Dortmund Univ, Dept Bldg Mat, Dortmund, Germany
[14] Univ Kassel, Dept Bldg Mat & Construct Chem, Kassel, Germany
关键词
ray tomography; micrographs; dynamic image analysis; Al-Si-Cu-alloys; wood-plastic composites (WPC); foam concrete; FIBER-REINFORCED POLYPROPYLENE; SI-CU ALLOYS; MECHANICAL-PROPERTIES; POLYMER COMPOSITES; COUPLING AGENT; PARTICLE-SIZE; FE-CONTENT; MICROTOMOGRAPHY; MORPHOLOGY;
D O I
10.3139/120.111076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The microstructural features of three different materials have been quantified by means of 2D image analysis and X-ray micro-computer tomography (CT) and the results were compared to determine the reliability of the 2D analysis in the material characterization. The 3D quantification of shrinkage pores and Fe-rich inclusions of an Al-Si-Cu alloy by X-ray tomography was compared with the statistical analysis of the 2D metallographic pictures and a significant difference in the results was found due to the complex morphology of shrinkage pores and Fe-rich particles. Furthermore, wood particles of a wood-plastic composite were measured by dynamic image analysis and X-ray tomography. Similar results were obtained for the maximum length of the particles, although the results of width differ considerably, which leads to a miscalculation of the particles aspect ratio. Finally, air voids of a foam concrete were investigated by the analysis of the 2D pictures in ImageJ and the results of the 2D circularity were compared with the values of the 3D elongation obtained by micro-computed tomography. The 3D analysis of the air voids in the foam concrete showed a more precise description of the morphology, although the 2D result are in good agreement with the results obtained by X-ray micro-tomography.
引用
收藏
页码:829 / 836
页数:8
相关论文
共 50 条
  • [21] TWO-DIMENSIONAL HIGH RESOLUTION X-RAY DETECTORS FOR IMAGING AND INTENSITY MEASUREMENTS
    Fandrich, F.
    Koehler, R.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C26 - C26
  • [22] Design, implementation and methods for the manufacture of components of a two-dimensional X-ray detector
    Ramos-Lerate, I
    Beltrán, D
    Magrans, I
    Martínez, JC
    Perlas, JA
    Bordas, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 197 - 200
  • [23] Multidirectional X-ray Dark-field Imaging With Two-dimensional Gratings
    Zanette, I.
    Rutishauser, S.
    David, C.
    Pfeiffer, F.
    Mohr, J.
    Weitkamp, T.
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 12 - 17
  • [24] Two-dimensional X-ray imaging using plastic scintillating fiber array
    Ma Qingli
    Tang Shibiao
    Zou Jiwei
    Xu Dongzhe
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (01) : 50 - 52
  • [25] Two-dimensional X-ray imaging using plastic scintillating fiber array
    MA Qingli1
    NuclearScienceandTechniques, 2008, (01) : 50 - 52
  • [26] Development of a two-dimensional imaging system of X-ray absorption fine structure
    Katayama, Misaki
    Sumiwaka, Koichi
    Hayashi, Kazuhiro
    Ozutsumi, Kazuhiko
    Ohta, Toshiaki
    Inada, Yasuhiro
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 717 - 721
  • [27] Measurement of Center of Rotation for Projection in X-ray Two-dimensional Computed Tomography System
    Li, Baolei
    Zhang, Yaojun
    Mo, Yang
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [28] Microstructural characterization of porous materials by two-dimensional X-ray refraction topography
    Harbich, KW
    Klobes, P
    Hentschel, MP
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 241 (1-3) : 225 - 229
  • [29] Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging
    Zakharova, Margarita
    Vlnieska, Vitor
    Fornasier, Heike
    Boerner, Martin
    Rolo, Tomy dos Santos
    Mohr, Juergen
    Kunka, Danays
    APPLIED SCIENCES-BASEL, 2018, 8 (03):
  • [30] Three-dimensional reciprocal space x-ray coherent scattering tomography of two-dimensional object
    Zhu, Zheyuan
    Pang, Shuo
    MEDICAL PHYSICS, 2018, 45 (04) : 1654 - 1661