Comparative investigation of two-dimensional imaging methods and X-ray tomography in the characterization of microstructure

被引:11
|
作者
Bacaicoa, Inigo [1 ,2 ]
Luetje, Martin [3 ]
Saelzer, Philipp [5 ]
Umbach, Cristin [4 ]
Brueckner-Foit, Angelika [6 ,7 ,8 ,9 ]
Heim, Hans-Peter [10 ,11 ]
Middendorf, Bernhard [12 ,13 ,14 ]
机构
[1] ITP, Aerosp Ind, Dept Mat & Special Proc, Zamudio, Spain
[2] Univ Kassel, Inst Mat Engn Qual & Reliabil, Field Casting Defects & Heat Treatment Optimizat, Kassel, Germany
[3] Univ Kassel, Inst Mat Engn Qual & Reliabil, Field Xray Tomog & Casting Defects Alloys, Kassel, Germany
[4] Univ Kassel, Dept Bldg Mats & Construct Chem, Inst Struct Engn, Kassel, Germany
[5] Univ Kassel, Dept Polymer Engn, Kassel, Germany
[6] Karlsruhe Res Ctr, Inst Mate Res 2, Dept Stochast, Karlsruhe, Germany
[7] Florida Atlantic Univ, Ctr Appl Stochast Res, Boca Raton, FL 33431 USA
[8] Univ Karlsruhe, Mech Engn Dept, Inst Reliabil & Damage, Karlsruhe, Germany
[9] Univ Kassel, Inst Mat Engn, Dept Qual & Reliabil, Kassel, Germany
[10] Univ Paderborn, Inst Plast Technol, Paderborn, Germany
[11] Univ Kassel, Plast Engin, Kassel, Germany
[12] Univ Kassel, Kassel, Germany
[13] TU Dortmund Univ, Dept Bldg Mat, Dortmund, Germany
[14] Univ Kassel, Dept Bldg Mat & Construct Chem, Kassel, Germany
关键词
ray tomography; micrographs; dynamic image analysis; Al-Si-Cu-alloys; wood-plastic composites (WPC); foam concrete; FIBER-REINFORCED POLYPROPYLENE; SI-CU ALLOYS; MECHANICAL-PROPERTIES; POLYMER COMPOSITES; COUPLING AGENT; PARTICLE-SIZE; FE-CONTENT; MICROTOMOGRAPHY; MORPHOLOGY;
D O I
10.3139/120.111076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The microstructural features of three different materials have been quantified by means of 2D image analysis and X-ray micro-computer tomography (CT) and the results were compared to determine the reliability of the 2D analysis in the material characterization. The 3D quantification of shrinkage pores and Fe-rich inclusions of an Al-Si-Cu alloy by X-ray tomography was compared with the statistical analysis of the 2D metallographic pictures and a significant difference in the results was found due to the complex morphology of shrinkage pores and Fe-rich particles. Furthermore, wood particles of a wood-plastic composite were measured by dynamic image analysis and X-ray tomography. Similar results were obtained for the maximum length of the particles, although the results of width differ considerably, which leads to a miscalculation of the particles aspect ratio. Finally, air voids of a foam concrete were investigated by the analysis of the 2D pictures in ImageJ and the results of the 2D circularity were compared with the values of the 3D elongation obtained by micro-computed tomography. The 3D analysis of the air voids in the foam concrete showed a more precise description of the morphology, although the 2D result are in good agreement with the results obtained by X-ray micro-tomography.
引用
收藏
页码:829 / 836
页数:8
相关论文
共 50 条
  • [1] Two-dimensional imaging X-ray spectrometer for plasma diagnostics
    Univ of Tsukuba, Tsukuba, Japan
    Fusion Eng Des, (189-191):
  • [2] Two-dimensional imaging X-ray spectrometer for plasma diagnostics
    Aota, T
    Yamaguchi, N
    Yoshikawa, M
    Ikeda, K
    Ishijima, T
    Okamoto, Y
    Mase, A
    Tamano, T
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 189 - 191
  • [3] On the range characterization for the two-dimensional attenuated x-ray transformation
    Novikov, RG
    INVERSE PROBLEMS, 2002, 18 (03) : 677 - 700
  • [4] Two-dimensional X-ray simulation based on Computed Tomography images
    Souza, F. F.
    Martins, T. A. C. P.
    Velho, T. R. D.
    Dalava, B. C.
    Silva, J. V. L.
    VIRTUAL AND RAPID MANUFACTURING: ADVANCED RESEARCH IN VIRTUAL AND RAPID PROTOTYPING, 2008, : 143 - 147
  • [5] Two-dimensional X-ray diffraction
    Kauffman, George B.
    FOUNDATIONS OF CHEMISTRY, 2012, 14 (02) : 187 - 188
  • [6] Two-dimensional imaging detectors for structural biology with X-ray lasers
    Denes, Peter
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2014, 369 (1647)
  • [7] Two-dimensional Detector for High Resolution Soft X-ray Imaging
    Ejima, Takeo
    Ogasawara, Shodo
    Hatano, Tadashi
    Yanagihara, Mihiro
    Yamamoto, Masaki
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 811 - 814
  • [8] Ultrafast two-dimensional x-ray imaging with x-ray streak cameras for laser fusion research (invited)
    Shiraga, H
    Miyanaga, N
    Heya, M
    Nakasuji, M
    Aoki, Y
    Azechi, H
    Yamanaka, T
    Mima, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 745 - 749
  • [9] Dimensional accuracy in X-ray computed tomography imaging
    Neel, ST
    Gibson, R
    Daniels, CR
    Klosterman, EL
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 411 - 418
  • [10] Introduction to two-dimensional X-ray diffraction
    He, BBP
    POWDER DIFFRACTION, 2003, 18 (02) : 71 - 85