Priming reduced extracorporeal circulation setup (PRECiSe) with the DeltaStream diagonal pump

被引:3
|
作者
Beholz, S [1 ]
Kessler, M [1 ]
Thölke, R [1 ]
Konertz, WF [1 ]
机构
[1] Humboldt Univ, Charite, Dept Cardiovasc Surg, D-10117 Berlin, Germany
关键词
cardiopulmonary bypass; hemodilution; diagonal-pump; biocompatibility; cardiac surgery;
D O I
10.1111/j.1525-1594.2003.07202.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Different systems for beating heart procedures and low priming systems limited to coronary artery bypass grafting (CABG) have been introduced. We describe Priming Reduced Extracorporeal Circulation Setup (PRECiSe), a new low priming system which sup-plies all the features of cardiopulmonary bypass (CPB). PRECiSe incorporates the DeltaStream diagonal pump, which pumps blood from the right atrium to the aorta via a membrane oxygenator and a filter; the system is placed beneath the patient's head resulting in extremely short tubing. A reservoir allows the use of suckers and vents. Autologous blood priming furthers reduces hemodilution. In a safety study the system was used for extracorporeal circulation in 11 patients undergoing CABG without adverse effects. By use of PRECiSe mean priming was reduced to 268.5 ml resulting in minimal hemo-dilution and transfusion requirements.
引用
收藏
页码:1110 / 1115
页数:6
相关论文
共 50 条
  • [1] PRECiSe (priming reduced extracorporeal circulation setup): Results of a safety study
    Beholz, S
    Kessler, M
    Konertz, WF
    [J]. HEART SURGERY FORUM, 2003, 6 (05): : 311 - 315
  • [2] A new rotary blood pump for versatile extracorporeal circulation:: the DeltaStream™
    Göbel, C
    Arvand, A
    Rau, G
    Reul, H
    Meyns, B
    Flameng, W
    Eilers, R
    Marseille, O
    [J]. PERFUSION-UK, 2002, 17 (05): : 373 - 382
  • [3] A new PRECiSe (priming reduced extracorporeal circulation setup) minimizes the need for blood transfusions: First clinical results in coronary artery bypass grafting
    Beholz, S
    Zheng, LL
    Kessler, M
    Rusche, M
    Konertz, W
    [J]. HEART SURGERY FORUM, 2005, 8 (03): : E132 - E135
  • [4] Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump
    Göbel, C
    Arvand, A
    Eilers, R
    Marseille, O
    Bals, C
    Meyns, B
    Flameng, W
    Rau, G
    Reul, H
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 358 - 365
  • [5] A PUMP FOR EXTRACORPOREAL CIRCULATION
    HALL, JE
    JAMES, PA
    LUCAS, BGB
    WATERSTON, DJ
    [J]. LANCET, 1959, 1 (FEB14): : 347 - 347
  • [6] Extracorporeal gas exchange with the DeltaStream rotary blood pump in experimental lung injury
    Dembinski, R
    Kopp, R
    Henzler, D
    Hochhausen, N
    Oslender, N
    Max, M
    Rossaint, R
    Kuhlen, R
    [J]. ARTIFICIAL ORGANS, 2003, 27 (06) : 530 - 536
  • [7] Successful use of a miniaturized bypass system with the DeltaStream extracorporeal rotary blood pump
    Christiansen, S
    Göbel, C
    Buhre, W
    Reul, H
    Autschbach, R
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (01): : 43 - 44
  • [8] GLYCEROL AS PRIMING SOLUTION FOR EXTRACORPOREAL CIRCULATION
    MANDAL, AK
    CALLAGHAN, JC
    DOLAN, AM
    STERNS, LP
    [J]. CANADIAN JOURNAL OF SURGERY, 1970, 13 (01) : 86 - +
  • [9] USE OF GELATINOUS PRIMING SOLUTION FOR EXTRACORPOREAL CIRCULATION
    SILVAY, J
    SUJANSKY, E
    SCHNORRER, M
    HRUBISKOVA, K
    SLEZAK, J
    GABAUER, I
    STYK, J
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 55 (03): : 350 - +
  • [10] OPERATION OF THE ROLLER PUMP FOR EXTRACORPOREAL CIRCULATION
    HEAD, LR
    COENEN, JP
    ANGOLA, E
    NOGUEIRA, C
    MENDELSOHN, D
    KAY, EB
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1960, 39 (02): : 210 - 220