A life-cycle energy analysis of building materials in the Negev desert

被引:231
|
作者
Huberman, N. [1 ]
Pearlmutter, D. [1 ]
机构
[1] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Albert Katz Int Sch Desert Studies, IL-84990 Sede Boqer, Israel
关键词
building materials; energy-efficiency; life-cycle analysis; embodied energy;
D O I
10.1016/j.enbuild.2007.06.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Environmental quality has become increasingly affected by the built environment-as ultimately, buildings are responsible for the bulk of energy consumption and resultant atmospheric emissions in many countries. In recognizing this trend, research into building energy-efficiency has focused mainly on the energy required for a building's ongoing use, while the energy "embodied" in its production is often overlooked. Such an approach has led in recent years to strategies which improve a building's thermal performance, but which rely on high embodied-energy (EE) materials and products. Although assessment methods and databases have developed in recent years, the actual EE intensity for a given material may be highly dependent on local technologies and transportation distances. The objective of this study is to identify building materials which may optimize a building's energy requirements over its entire life cycle, by analyzing both embodied and operational energy consumption in a climatically responsive building in the Negev desert region of southern Israel-comparing its actual material composition with a number of possible alternatives. It was found that the embodied energy of the building accounts for some 60% of the overall life-cycle energy consumption, which could be reduced significantly by using "alternative" wall infill materials. The cumulative energy saved over a 50-year life cycle by this material substitution is on the order of 20%. While the studied wall systems (mass, insulation and finish materials) represent a significant portion of the initial EE of the building, the concrete structure (columns, beams, floor and ceiling slabs) on average constitutes about 50% of the building's pre-use phase energy. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:837 / 848
页数:12
相关论文
共 50 条
  • [21] A comprehensive framework for assessing the life-cycle energy of building construction assemblies
    Crawford, Robert H.
    Czerniakowski, Isabella
    Fuller, Robert J.
    ARCHITECTURAL SCIENCE REVIEW, 2010, 53 (03) : 288 - 296
  • [22] Analysing the life-cycle energy of an Australian residential building and its householders
    Treloar, G
    Fay, R
    Love, PED
    Iyer-Raniga, U
    BUILDING RESEARCH AND INFORMATION, 2000, 28 (03): : 184 - 195
  • [23] Analysis of Building Life Cycle Energy Consumption Based on the Wall Insulation Materials
    Zhao, Lina
    Yang, Junlan
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MATERIALS, ENVIRONMENTAL AND BIOLOGICAL ENGINEERING, 2015, 10 : 768 - 773
  • [24] Life-cycle energy analysis of building integrated photovoltaic systems (BiPVs) with heat recovery unit
    Crawford, R. H.
    Treloar, G. J.
    Fuller, R. J.
    Bazillan, M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2006, 10 (06): : 559 - 575
  • [25] Life-cycle energy and greenhouse gas analysis of three building types in a residential area in Lisbon
    Bastos, Joana
    Batterman, Stuart A.
    Freire, Fausto
    ENERGY AND BUILDINGS, 2014, 69 : 344 - 353
  • [26] Energy and environmental life-cycle analysis of advanced windows
    Griffiths, PW
    Eames, PC
    Lo, SNG
    Norton, B
    RENEWABLE ENERGY, 1996, 8 (1-4) : 219 - 222
  • [27] LIFE-CYCLE ANALYSIS
    MUNN, P
    JOCCA-SURFACE COATINGS INTERNATIONAL, 1995, 78 (02): : 78 - 78
  • [28] Life-cycle energy analysis of buildings: a case study
    Fay, R
    Treloar, G
    Iyer-Raniga, U
    BUILDING RESEARCH AND INFORMATION, 2000, 28 (01): : 31 - 41
  • [29] ENERGY IN THE LIFE-CYCLE OF POLYMERS
    EAGLES, AE
    PLASTICS & RUBBER INTERNATIONAL, 1985, 10 (02): : 30 - &
  • [30] LIFE-CYCLE ANALYSIS OF RENEWABLE ENERGY-SYSTEMS
    SORENSEN, B
    RENEWABLE ENERGY, 1994, 5 (5-8) : 1270 - 1277