Shaking table tests of 1:4 reduced-scale models of masonry infilled reinforced concrete frame buildings

被引:66
|
作者
Zarnic, R
Gostic, S
Crewe, AJ
Taylor, CA
机构
[1] Univ Ljubljana, Fac Civil & Geodet Engn, Ljubljana 1001, Slovenia
[2] Civil Engn Inst ZRMK, Ljubljana, Slovenia
[3] Univ Bristol, Dept Civil Engn, Earthquake Engn Res Ctr, Bristol BS8 1TR, Avon, England
来源
关键词
infilled frame; building model; true replica; shaking table; non-linear response;
D O I
10.1002/eqe.39
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Two models of masonry infilled reinforced concrete frame buildings were tested at the shaking table. Models were built in the reduced scale 1:4 using the materials produced in accordance to modelling demands of true replica modelling technique. The first model represented a one-storey box-like building and the second one the two-stories building with plan shaped in the form of a letter H. Models were shaken with the series of horizontal sine dwell motions with gradually increasing amplitude. Masonry infills of tested models were constructed of relatively strong bricks laid in weak mortar. Therefore, typical cracks developed and propagated along mortar beds without cracking of bricks or crushing of infill corners. Data collected from tests will be used in future evaluation, verification and development of computational models for prediction of in-plane and out-of-plane behaviour of masonry infills. The responses of rested models can be well compared with global behaviour of real structures using the modelling rules. The similarity of local behaviour of structural elements, e.g. reinforced concrete joints, is less reliable due to limitations in modelling of steel reinforcement properties. The model responses showed that buildings designed according to Eurocodes are able to sustain relatively high dynamic excitations due to a significant level of structural overstrength. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:819 / 834
页数:16
相关论文
共 50 条
  • [31] Shake-table tests of a three-story reinforced concrete frame with masonry infill walls
    Stavridis, Andreas
    Koutromanos, I.
    Shing, P. B.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (06): : 1089 - 1108
  • [32] Shaking table tests of a one-quarter scale model of concrete hollow block masonry houses retrofitted with fiber-reinforced paint
    Multazam, Zamzam
    Yamamoto, Kenjiro
    Timsina, Kishor
    Gadagamma, Chaitanya Krishna
    Meguro, Kimiro
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [33] Dynamic deformability evaluated by series of shaking table tests of full-scale models of masonry houses
    Hanazato, T.
    Seno, H.
    Niitsu, Y.
    Imai, H.
    Narafu, T.
    Mikoshiba, T.
    Minowa, C.
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 2417 - 2424
  • [34] Seismic response analyses and performance assessment of masonry-infilled reinforced concrete frame buildings in Bhutan without and with soft storey
    Thinley, Kinzang
    Hao, Hong
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (05) : 822 - 839
  • [35] Investigation on Seismic Performance of Bidirectional Self-Centering Reinforced Concrete Frame Structures by Shaking Table Tests
    Wang, Zhenying
    Mao, Chenxi
    Xie, Lili
    SHOCK AND VIBRATION, 2020, 2020
  • [36] Seismic strengthening of low-rise reinforced concrete frame structures with masonry infill walls: Shaking-table test
    Benavent-Climent, A.
    Ramirez-Marquez, A.
    Pujol, S.
    ENGINEERING STRUCTURES, 2018, 165 : 142 - 151
  • [37] Floor acceleration amplification and response spectra of reinforced concrete frame structure based on shaking table tests and numerical study
    Zou, Xiaoguang
    Yang, Weiguo
    Liu, Pei
    Wang, Meng
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2023, 23 (03)
  • [38] Shaking table tests for aseismic performance of a controllable rocking reinforced concrete frame with column-end-hinge joints
    Lu L.
    Jiang L.
    Li H.
    Lü X.-L.
    2016, Chinese Vibration Engineering Society (35): : 193 - 198and216
  • [39] Shaking-table tests of a full-scale single-story masonry veneer wood-frame structure
    Okail, Hussein O.
    Shing, P. Benson
    McGinley, William M.
    Klingner, Richard E.
    Jo, Seongwoo
    McLean, David I.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (05): : 509 - 530
  • [40] Shaking Table Tests of a Reduced-Scale UHV Transmission Tower-Line System Subjected to Near-Fault Ground Motions
    Tian, Li
    Zhou, Mengyao
    Pan, Haiyang
    Xin, Aiqiang
    Liu, Yuping
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (06)