Design and analysis of a mechanical ventilation system based on cams

被引:2
|
作者
Calderon, J. Alan Ch [1 ,2 ]
Rincon, Carlos [2 ]
Agreda, Martin [2 ]
Jimenez de Cisneros, Juan Jose [2 ]
机构
[1] Tech Univ Ilmenau, Inst Phys, Angew Nanophys, D-98693 Ilmenau, Germany
[2] Pontificia Univ Catolica Peru, Engn Dept, Lima 15088, Peru
关键词
Mechanical ventilation design; Low-cost mechanical ventilator; Experimental ventilation curves; Mechanical ventilation mathematical model; COVID-19;
D O I
10.1016/j.heliyon.2021.e08195
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Low-cost mechanical ventilators have been developed in order to deal with the shortage of traditional ventilators whose quantity is not sufficient in an emergency context in Peru. Protofy, a company from Spain, designed one of the first low-cost mechanical ventilation systems OxyGEN which was approved by a medicine agency in its country in special context of COVID 19. Therefore, as main of this article, a redesign of this system named OxygenIP.PE was carried out according to local requirements and available technology, but maintaining its working concept based on compression mechanism by cams. Sensors were added and a control algorithm of the respiratory rate was developed. Ventilation curves monitoring over time was implemented; in this sense, a mathematical model of the whole system was developed. OxygenIP.PE was redesigned, fabricated, and tested measuring its ventilation curves over time. Results indicate that this redesign provides a sturdy equipment able to work during a longer lifetime than the original. The replicability of the ventilation curves behavior is ensured, while the mechanism dimensions are adapted for a particular airbag resuscitator. The mathematical model of the whole system can satisfactorily determine the ventilation curves over time and is used to show the air pressure, volume, and flow as a function of the compression arm's angular position and differential pressure through the breathing circuit measurement, furthermore the algorithms designed as a consequence of the mathematical model were implemented for Raspberry and ARDUINO microcontrollers. There were obtained parameters of pressure 10-65 cmH2O, airflow 50-65 l/m, volume 0-0.5 l, at two values of beat per minute (BPM) 15 and 25.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] CHALLENGE - TO DESIGN BETTER CAMS
    HAIN, K
    JOURNAL OF MECHANISMS, 1970, 5 (03): : 283 - &
  • [32] MECHANICAL VENTILATION - PHYSIOLOGY, EQUIPMENT DESIGN, AND MANAGEMENT
    POPOVICH, J
    POSTGRADUATE MEDICINE, 1986, 79 (01) : 217 - +
  • [33] Application analysis on night mechanical ventilation in northern areas based on EnergyPlus
    Gao, Fusheng
    Yi, Lingli
    Wang, Zhaojun
    Shenyang Jianzhu Daxue Xuebao (Ziran Kexue Ban)/Journal of Shenyang Jianzhu University (Natural Science), 2008, 24 (02): : 291 - 296
  • [34] ICESat-2 Constraint Analysis and Monitoring System (CAMS)
    Rebold, T. W.
    Luthcke, S. B.
    Pennington, T. A.
    Syed, A.
    Beall, J. L.
    Sabaka, T. J.
    EARTH AND SPACE SCIENCE, 2021, 8 (05)
  • [35] Design and Analysis of a Heating, Ventilation and Air Conditioning System for Electric Vehicles
    Cosman, Sorin-Iulian
    Vascan, Iulia
    Bilatiu, Cristina-Adina
    Tintelecan, Adriana
    Martis, Claudia Steluta
    Zorlescu, Bica
    2020 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM 2020), 2020, : 305 - 310
  • [36] Performance analysis of a new design of office diffuse ceiling ventilation system
    Fan, Jianhua
    Hviid, Christian Anker
    Yang, Honglu
    ENERGY AND BUILDINGS, 2013, 59 : 73 - 81
  • [37] Mechanical design requirements analysis based on DQFD
    School of Management, Zhejiang University, Zhejiang, 310058, Hangzhou, China
    不详
    Wei, X., 2013, Asian Network for Scientific Information (12)
  • [38] WEANING PATIENTS FROM MECHANICAL VENTILATION - A KNOWLEDGE-BASED SYSTEM APPROACH
    TONG, DA
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1991, 35 (04) : 267 - 278
  • [39] IFC-based performance data checking for ventilation system design
    Xu, Lei
    Adachi, Yoshinobu
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2023, 22 (03) : 1226 - 1234
  • [40] IFC-based performance data checking for ventilation system design
    Xu, Lei
    Adachi, Yoshinobu
    Journal of Asian Architecture and Building Engineering, 2023, 22 (03): : 1226 - 1234