Fabrication and characterization of all-polystyrene microfluidic devices with integrated electrodes and tubing

被引:0
|
作者
Pentecost, Amber M. [1 ]
Martin, R. Scott [1 ]
机构
[1] St Louis Univ, Dept Chem, St Louis, MO 63103 USA
关键词
CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; MICROCHIP ELECTROPHORESIS; NITRIC-OXIDE; MULTIPLE COMPONENTS; CELL; MICROELECTRODES; PEROXYNITRITE; SYSTEMS;
D O I
10.1039/c5ay00197h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method of fabricating all-polystyrene devices with integrated electrodes and fluidic tubing is described. As opposed to expensive polystyrene (PS) fabrication techniques that use hot embossing and bonding with a heated lab press, this approach involves solvent-based etching of channels and lamination-based bonding of a PS cover, all of which do not need to occur in a cleanroom. PS has been studied as an alternative microchip substrate to PDMS, as it is more hydrophilic, biologically compatible in terms of cell adhesion, and less prone to absorption of hydrophobic molecules. The etching/lamination-based method described here results in a variety of all-PS devices, with or without electrodes and tubing. To characterize the devices, micrographs of etched channels (straight and intersected channels) were taken using confocal and scanning electron microscopy. Microchip-based electrophoresis with repetitive injections of fluorescein was conducted using a three-sided PS (etched pinched, twin-tee channel) and one-sided PDMS device. Microchip-based flow injection analysis, with dopamine and NO as analytes, was used to characterize the performance of all-PS devices with embedded tubing and electrodes. Limits of detection for dopamine and NO were 130 nM and 1.8 mu M, respectively. Cell immobilization studies were also conducted to assess all-PS devices for cellular analysis. This paper demonstrates that these easy to fabricate devices can be attractive alternative to other PS fabrication methods for a wide variety of analytical and cell culture applications.
引用
收藏
页码:2968 / 2976
页数:9
相关论文
共 50 条
  • [41] Fabrication and characterization of poly(methylmethacrylate) microfluidic devices bonded using surface modifications and solvents
    Brown, L
    Koerner, T
    Horton, JH
    Oleschuk, RD
    LAB ON A CHIP, 2006, 6 (01) : 66 - 73
  • [42] Fabrication of a new all-in-one microfluidic dielectrophoresis integrated chip and living cell separation
    Oshiro, Kyoichi
    Wakizaka, Yoshikazu
    Takano, Masayo
    Itoi, Takayuki
    Ohge, Hiroki
    Koba, Kazumi
    Yarimizu, Kyoko
    Fujiyoshi, So
    Maruyama, Fumito
    ISCIENCE, 2022, 25 (02)
  • [43] Simplified fabrication of integrated microfluidic devices using fused deposition modeling 3D printing
    Gaal, Gabriel
    Mendes, Melissa
    de Almeida, Tiago P.
    Piazzetta, Maria H. O.
    Gobbi, Angelo L.
    Riul, Antonio, Jr.
    Rodrigues, Varlei
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 35 - 40
  • [44] Design and fabrication of microfluidic devices integrated with an open‐ended MEMS probe for single‐cell impedance measurement
    Ling-Sheng Jang
    Hsin-Hung Li
    Jen-Yu Jao
    Ming-Kun Chen
    Chia-Feng Liu
    Microfluidics and Nanofluidics, 2010, 8 : 509 - 519
  • [45] Fabrication of the microfluidic chips with integrated ultra-micro electrodes and its application in on-chip electrochemical detection
    Jin, Y
    Luo, GA
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (07): : 1180 - 1184
  • [46] Fabrication and characterization of photorefractive platforms in lithium niobate for recording of integrated holographic devices
    Bazzan, M.
    Ciampolillo, M. V.
    Zaltron, A.
    Argiolas, N.
    Sada, C.
    Kokanian, N.
    Fontana, M. D.
    2012 INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS HELD JOINTLY WITH 11TH IEEE ECAPD AND IEEE PFM (ISAF/ECAPD/PFM), 2012,
  • [47] Rapid prototyping of microfluidic devices with integrated wrinkled gold micro-/nano textured electrodes for electrochemical analysis
    Gabardo, C. M.
    Adams-McGavin, R. C.
    Vanderfleet, O. M.
    Soleymani, L.
    ANALYST, 2015, 140 (16) : 5781 - 5788
  • [48] Characterization of electrowetting, contact angle hysteresis, and adhesion on digital microfluidic devices with inkjet-printed electrodes
    Bernetski, Kimberly A.
    Burkhart, Collin T.
    Maki, Kara L.
    Schertzer, Michael J.
    MICROFLUIDICS AND NANOFLUIDICS, 2018, 22 (09)
  • [49] Bench-Top Fabrication of an All-PDMS Microfluidic Electrochemical Cell Sensor Integrating Micro/Nanostructured Electrodes
    Saem, Sokunthearath
    Zhu, Yujie
    Luu, Helen
    Moran-Mirabal, Jose
    SENSORS, 2017, 17 (04)
  • [50] Fabrication and Characterization of All-Plastic Flexible Microfluidic Chip using Thermal Lamination of Patterned Sheet
    Wijaya, Willy
    Uranus, Henri P.
    2015 4TH INTERNATIONAL CONFERENCE ON INSTRUMENTATION, COMMUNICATIONS, INFORMATION TECHNOLOGY, AND BIOMEDICAL ENGINEERING (ICICI-BME), 2015, : 254 - 259