Real-time PDT Dose Dosimetry for Pleural Photodynamic Therapy

被引:9
|
作者
Zhu, Timothy C. [1 ]
Sun, Hongjing [1 ]
Ong, Yi-Hong [1 ]
Morales, Ryan Hall [1 ]
Dimofte, Andreea [1 ]
Busch, Theresa [1 ]
Singhal, Sunil [2 ]
Cengel, Keith A. [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Surg, Philadelphia, PA 19104 USA
关键词
PDT dose; Photofrin; Pleural PDT; IR navigation system; photodynamic therapy; EXPLICIT DOSIMETRY;
D O I
10.1117/12.2612188
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), an eight-channel PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously from eight different sites in the pleural cavity during PDT. An isotropic detector with bifurcated fibers was used for each channel to ensure detected light was split equally to the photodiode and spectrometer. The light fluence rate distribution is monitored using an IR navigation system. The navigation system allows 2D light fluence mapping throughout the whole pleural cavity rather than just the selected points. The fluorescence signal is normalized by the light fluence measured at treatment wavelength. We have shown that the absolute photosensitizer concentration can be obtained by applying optical properties correction and linear spectral fitting to the measured fluorescence data. The detection limit and the optical property correction factor of each channel were determined and validated using tissue-simulating phantoms with known varying concentration of Photofrin. Tissue optical properties are determined using an absorption spectroscopy probe immediately before PDT at the same sites. The combination of 8-channel PDT dosimeter system and IR navigation system, which can calculate light fluence rate in the pleural cavity in real-time, providing a mean to determine the distribution of PDT dose on the entire pleural cavity to investigate the heterogeneity of PDT dose on the pleural cavity.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Photodynamic therapy dosimetry using multiexcitation multiemission wavelength: toward real-time prediction of treatment outcome
    Mousavi, Monirehalsadat
    Moriyama, Lilian Tan
    Grecco, Clovis
    Nogueira, Marcelo Saito
    Svanberg, Katarina
    Kurachi, Cristina
    Andersson-Engels, Stefan
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (06)
  • [22] Real-time dosimetry in external beam radiation therapy
    Prabhakar, Ramachandran
    WORLD JOURNAL OF RADIOLOGY, 2013, 5 (10): : 352 - 355
  • [23] Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy
    Beddar, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3790 - 3790
  • [24] Volumetric Dose Deposition in the Breast Using Real-Time Dosimetry
    Nosratieh, A.
    Burkett, G.
    Boone, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [25] Feasibility of using fluoresceinyl Cypridina luciferin analog in a novel chemiluminescence method for real-time photodynamic therapy dosimetry
    Qin, YF
    Xing, D
    Luo, SM
    Zhou, J
    Zhong, XY
    Chen, Q
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2005, 81 (06) : 1534 - 1538
  • [26] Photodynamic Therapy (PDT): PDT Mechanisms
    Allison, Ron R.
    Moghissi, Keyvan
    CLINICAL ENDOSCOPY, 2013, 46 (01) : 24 - 29
  • [27] Photodynamic therapy (PDT)
    Wolf, P
    HAUTARZT, 1997, 48 (02): : 137 - 148
  • [28] Photodynamic Therapy (PDT)
    Berlien, Hans-Peter
    Journal of Biophotonics, 2016, 9 (11-12) : 1300 - 1301
  • [29] In-vivo Light dosimetry for pleural PDT
    Dimofte, Andreea
    Zhu, Timothy C.
    Finlay, Jarod C.
    Cullighan, Melissa
    Edmonds, Christine E.
    Friedberg, Joseph S.
    Cengel, Keith
    Hahn, Stephen M.
    OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XVIII, 2009, 7164
  • [30] Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT
    Kim, M.
    Penjweini, R.
    Zhu, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3672 - 3672