A multichannel magnetic stimulation system using submillimeter-sized coils: system development and experimental application to rodent brain in vivo

被引:22
|
作者
Minusa, Shunsuke [1 ]
Muramatsu, Shuto [1 ]
Osanai, Hisayuki [1 ]
Tateno, Takashi [1 ]
机构
[1] Hokkaido Univ, Grad Sch Informast Sci & Technol, Bioengn & Bioinformat, Kita Ku, Kita 14,Nishi 9, Sapporo, Hokkaido 0600814, Japan
关键词
current assignment; focality; numerical optimization; micro magnetic stimulation; multichannel; power reduction; MOUSE AUDITORY-CORTEX; ELECTRIC-FIELD; TMS; DESIGN; NERVE; DEEP; RESPONSES; FOCALITY; MINIMUM; DENSITY;
D O I
10.1088/1741-2552/ab3187
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Single coil-based systems for magnetic stimulation are widely used for neurostimulation in neuroscience research and clinical treatment of neurological diseases. However, parallelization of magnetic stimulation with multiple coils may generate far greater potential than a single coil, and could thus expand the scope of brain area stimulation. Therefore, we examined whether a multiple coil-based system could improve the effectiveness and focality of conventional single coil-based magnetic stimulation. Approach. We designed and tested a micromagnetic stimulation (mu MS) device with multiple submillimeter-sized coils as a possible substitute for one large coil. Our design concept is spatially-distributed stimulation strategy involving the small number of coils to be able to mimic desired electric field profiles. To this end, the cost function of the error between the desired and coil-induced electric fields was firstly calculated, and coil currents were repetitively estimated to achieve the smaller number of coils under a certain criterion: a minimum error with spatial sparsity. Using these approaches, we evaluated the capability of our multi-channel mu MS via numerical simulations and demonstrated responsive results in animal experiments. Main results. Our approach can enhance control of neural excitation and improve the concentration of the excitation field induced by magnetic stimulation with reduced power consumption. Furthermore, in vivo electrophysiological recordings of mouse brain performed to evaluate our proposed approach for brain stimulation demonstrated experimentally that our multi-channel mu MS device can yield more effective stimulation than the single-channel device. In addition, our device permitted electronic spatial adjustment of the stimulus shape and location without moving the coils. Significance. The development of new multichannel mu MS-based therapeutic approaches may be useful because the mu MS affects only a restricted brain area. Indeed, the small size of micro-coils and their finer focality with multichannel contribution might be suitable for chronic use, which is difficult using conventional large transcranial magnetic stimulation (TMS) with simple round or figure-eight coils. Thus, our findings support new opportunities to explore magnetic stimulation as a therapeutic approach for neurological disorders.
引用
收藏
页数:21
相关论文
共 27 条
  • [21] A Novel Electrophysiological Technique for Rat Hippocampal CA1 Area Field Potential Recording in vivo: Development and Application of Stimulation/Recording/Drug Delivery System
    Wang Xiao-Hui
    Yang Wei
    Yuan Li
    Li Shao-Feng
    Yang Dong
    Pan Yan-Fang
    Qi Jin-Shun
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2011, 38 (04) : 370 - 377
  • [22] Analysis on fault current limiting and bus-voltage sag suppressing operations of SFCLs using magnetic coupling of two coils according to their application locations in a power distribution system
    Kim, J. S.
    Lim, S. H.
    Kim, J. C.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2011, 471 (21-22): : 1358 - 1363
  • [23] Probing the Brain-Body Connection Using Transcranial Magnetic Stimulation (TMS): Validating a Promising Tool to Provide Biomarkers of Neuroplasticity and Central Nervous System Function
    Chaves, Arthur R.
    Snow, Nicholas J.
    Alcock, Lynsey R.
    Ploughman, Michelle
    BRAIN SCIENCES, 2021, 11 (03)
  • [24] Automated Analysis of Urinary Stone Composition Using Raman Spectroscopy: Pilot Study for the Development of a Compact Portable System for Immediate Postoperative Ex Vivo Application
    Miernik, Arkadiusz
    Eilers, Yvan
    Bolwien, Carsten
    Lambrecht, Armin
    Hauschke, Dieter
    Rebentisch, Gunter
    Lossin, Phillipp S.
    Hesse, Albrecht
    Rassweiler, Jens J.
    Wetterauer, Ulrich
    Schoenthalerk, Martin
    JOURNAL OF UROLOGY, 2013, 190 (05): : 1895 - 1900
  • [25] Application of an interface system for the development of a three dimensional finite element model of the knee joint using magnetic resonance imaging (MRI) data.
    Diamantopoulos, P
    Richardson, JD
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 437 - 443
  • [26] In Vivo Quantification of Inflammation in Experimental Autoimmune Encephalomyelitis Rats Using Fluorine-19 Magnetic Resonance Imaging Reveals Immune Cell Recruitment outside the Nervous System
    Zhong, Jia
    Narsinh, Kazim
    Morel, Penelope A.
    Xu, Hongyan
    Ahrens, Eric T.
    PLOS ONE, 2015, 10 (10):
  • [27] Development of a Beta-sensing Pathway in Deep brain stimulation to optimise utility of Local field potential recordings using the Percept system (Newcastle Beta-sensing Algorithm - NBA)
    Gibbs, M.
    Mills, R.
    Hussain, A.
    Jenkins, A.
    Nicholson, C.
    Pavese, N.
    Ledingham, D.
    MOVEMENT DISORDERS, 2024, 39 : S556 - S556