Assay of an alpha solid waste drum using passive neutron counting

被引:0
|
作者
Sivakumar, P. [1 ]
Govindan, P. [1 ]
Ananthasivan, K. [1 ]
机构
[1] Indira Gandhi Ctr Atom Res, Reproc Grp, Kalpakkam 603102, Tamil Nadu, India
关键词
Drum monitoring; Alpha waste; Passive neutron counting; NONDESTRUCTIVE ASSAY; SYSTEM;
D O I
10.1007/s10967-022-08400-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A passive neutron based assaying system for plutonium bearing solid wastes has been designed and developed. The assaying of the plutonium in the drum containing the wastes is determined by as positioned and by rotating the drum to 180 degree and average counts are obtained. The average counts were used for deriving the counting statistics. This system was calibrated with plutonium typically obtained in fast reactor fuel reprocessing facilities with known isotopic compositions. The minimum detection limit has been estimated to be 35 mg. It has been determined that a gamma background of up to 2000 mR/h can be tolerated without loss of accuracy.
引用
收藏
页码:3857 / 3864
页数:8
相关论文
共 50 条
  • [31] Passive assay of plutonium metal plates using a fast-neutron multiplicity counter
    Di Fulvio, A.
    Shin, T. H.
    Jordan, T.
    Sosa, C.
    Ruch, M. L.
    Clarke, S. D.
    Chichester, D. L.
    Pozzi, S. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 855 : 92 - 101
  • [32] Defined solid angle alpha counting at NPL
    Arinc, Arzu
    Parfitt, Michael J.
    Keightley, John D.
    Wilson, Alan
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 198 - 204
  • [33] PLUTONIUM MEASUREMENT IN SCRAP AND WASTE USING HIGH-SENSITIVITY PASSIVE NEUTRON DETECTORS
    MENLOVE, HO
    PICKRELL, MM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 128 - NUCL
  • [34] Active and passive CT for waste assay using LaBr3(Ce) detector
    Roy, Tushar
    More, M. R.
    Ratheesh, Jilju
    Sinha, Amar
    RADIATION PHYSICS AND CHEMISTRY, 2017, 130 : 29 - 34
  • [35] Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting
    Bourva, LCA
    Croft, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (03): : 485 - 508
  • [36] Feynman variance-to-mean in the context of passive neutron coincidence counting
    Croft, S.
    Favalli, A.
    Hauck, D. K.
    Henzlova, D.
    Santi, P. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 686 : 136 - 144
  • [37] Performance Characteristics of a High Efficiency Passive Neutron Assay System using Alternative Neutron Detectors to Helium-3
    Simpson, A. P.
    Jones, S.
    Clapham, M. J.
    McElhaney, S. A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4853 - 4857
  • [38] Improving acidogenic performance in anaerobic degradation of solid organic waste using a rotational drum fermentation system
    Jiang, WZ
    Kitamura, Y
    Li, BM
    BIORESOURCE TECHNOLOGY, 2005, 96 (14) : 1537 - 1543
  • [39] EVALUATING ROTARY DRUM AIR CLASSIFICATION OF SHREDDED SOLID-WASTE
    GRUBBS, MR
    COULOMBE, EJ
    CONSERVATION & RECYCLING, 1979, 3 (01): : 45 - 51
  • [40] NEUTRON MULTIPLICATION MEASUREMENTS USING MOMENTS OF THE NEUTRON COUNTING DISTRIBUTION
    ROBBA, AA
    DOWDY, EJ
    ATWATER, HF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 215 (03): : 473 - 479