Comparison of peak expiratory flow variability between workers with work-exacerbated asthma and occupational asthma

被引:34
|
作者
Chiry, Samah
Cartier, Andre
Malo, Jean-Luc
Tarlo, Susan M.
Lemiere, Catherine
机构
[1] Hop Sacre Coeur, Dept Chest Med, Montreal, PQ H4J 1C5, Canada
[2] Toronto Western Hosp, Gage Occupat & Environm Hlth Unit, Toronto, ON M5T 2S8, Canada
基金
加拿大健康研究院;
关键词
occupational asthma; peak expiratory flow; work-exacerbated asthma;
D O I
10.1378/chest.07-0460
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Peak expiratory flow (PEF) monitoring is frequently used to diagnose occupational asthma (OA). The variability of PEF between periods at work and away from work has not been described in workers with work-exacerbated asthma (WEA). We sought to assess and compare the diurnal variability of PEF during periods at and away from work between subjects with OA and WEA. Methods: Workers referred for work-related asthma underwent PEF monitoring for 2 weeks at and away from work. The diagnostic of OA or WEA was subsequently made according to the respective positivity or negativity of the specific inhalation challenges. PEF mean diurnal variability was calculated during periods at and away from work. PEF graphs were also interpreted using direct visual analysis by five observers and using a computer program (Oasys-2, Expert System) [available at: http://www.occupationalasdnna.coml. Results: Thirty-four subjects were investigated (WEA, n = 15; OA, n = 19). There was a greater variability of PEF at work than away from work in both OA (19.8 +/- 8.7% vs 10.7 +/- 6.3%, p < 0.001) and WEA (14.2 +/- 4.8% vs 10.6 +/- 5.6%, p = 0.02). However, the magnitude of the variability was higher in OA than in WEA (p = 0.02). The visual interpretation of PEF or the Oasys-2 program failed to distinguish WEA from OA. Conclusion: Although workers with OA showed a higher PEF variability than workers with WEA when at work, clinicians were unable to reliably differentiate OA from WEA using the visual interpretation of PEF graphs or the computerized analysis.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 50 条
  • [31] Diagnosis and frequency of work-exacerbated asthma among bakers
    Wiszniewska, Marta
    Walusiak-Skorupa, Jolanta
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2013, 111 (05) : 370 - 375
  • [32] Serial peak expiratory flow measurement in the diagnosis of occupational asthma
    Gannon, PFG
    Burge, PS
    EUROPEAN RESPIRATORY JOURNAL, 1997, 10 : S57 - S63
  • [33] PEAK EXPIRATORY FLOW-RATES IN POSSIBLE OCCUPATIONAL ASTHMA
    LISS, GM
    TARLO, SM
    CHEST, 1991, 100 (01) : 63 - 69
  • [34] PEAK EXPIRATORY FLOW-RATES IN POSSIBLE OCCUPATIONAL ASTHMA
    LISS, GM
    TARLO, SM
    CHEST, 1991, 100 (05) : 1480 - 1480
  • [35] Work-exacerbated asthma among bakers - the frequency and diagnostic difficulties
    Wiszniewska, M.
    Lipinska-Ojrzanowska, A.
    Nowakowska-Wirta, E.
    Tymoszuk, D.
    Paczynski, C.
    Walusiak-Skorupa, J.
    ALLERGY, 2012, 67 : 585 - 585
  • [36] An Official American Thoracic Society Statement: Work-Exacerbated Asthma
    Henneberger, Paul K.
    Redlich, Carrie A.
    Callahan, David B.
    Harber, Philip
    Lemiere, Catherine
    Martin, James
    Tarlo, Susan M.
    Vandenplas, Olivier
    Toren, Kjell
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 184 (03) : 368 - 378
  • [37] Prevalence Of Work-Exacerbated Asthma: A Systematic Review Of Published Studies
    Henneberger, P. K.
    Toren, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [38] THE EFFECT OF SHIFT WORK ON SERIAL PEAK EXPIRATORY FLOW MEASUREMENTS USED TO DIAGNOSE OCCUPATIONAL ASTHMA
    Moore, V. C.
    Jaakkola, M. S.
    Burge, C. B. S. G.
    Pantin, C. F. A.
    Robertson, A. S.
    Burge, P. S.
    THORAX, 2010, 65 : A72 - A73
  • [39] Secondary Prevention of Work-Exacerbated Asthma: Evaluation of the Questionnaire Prediction Model
    Pralong, Jacques A.
    Moullec, G.
    Dorribo, V.
    Lemiere, C.
    Suarthana, E.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2014, 56 (07) : E55 - E57
  • [40] Comparison of serial monitoring of peak expiratory flow and FEV1 in the diagnosis of occupational asthma
    Leroyer, C
    Perfetti, L
    Trudeau, C
    L'Archevêque, J
    Chan-Yeung, M
    Malo, JL
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (03) : 827 - 832