Microdevice with integrated dialysis probe and biosensor array for continuous multi-analyte monitoring

被引:33
|
作者
Petrou, PS
Moser, I
Jobst, G
机构
[1] Univ Freiburg, Fak Angew Wissensch, Inst Mikrosyst Tech, D-79110 Freiburg, Germany
[2] NCSR Demokritos, Immunoassay Lab, IRRP, Athens 15310, Greece
来源
BIOSENSORS & BIOELECTRONICS | 2003年 / 18卷 / 5-6期
关键词
BioMEMS; microdialysis; glucose; lactate; continuous monitoring; microfabrication;
D O I
10.1016/S0956-5663(03)00038-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The simultaneous on-line determination of glucose and lactate using a microdevice that consisted of a dialysis sampling system incorporated to the flow-through cell of a microfabricated biosensor array is presented. The fluidic connections between the different device's components were realized by subsequent processing of stacked dry resist layers on a plastic support that provided also the means for electric connections. The performance of the device was evaluated in vitro. The cross-talk effect on the downstream sensor was investigated and found to be negligible. Recoveries of over 95% for both analytes were achieved when flow rates of the perfusion fluid less than or equal to 0.5 mul/min were used. At this flow rate, the response time of the device was 2.4 min, which is acceptable for on-line analysis. The linear response concentration range extended up to 30 mM for glucose and 15 mM for lactate. Interference from electroactive species such as ascorbic acid, 2-acetamidophenol and uric acid, was minimal (less than 5% increase in biosensors signal for all substances tested). In addition, the device presented long-term run stability both in buffer and serum samples. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 50 条
  • [31] Multi-analyte single-membrane biosensor for the serotype-specific detection of Dengue virus
    Natalya V. Zaytseva
    Richard A. Montagna
    Eun Mi Lee
    Antje J. Baeumner
    Analytical and Bioanalytical Chemistry, 2004, 380 : 46 - 53
  • [32] Multi-analyte single-membrane biosensor for the serotype-specific detection of Dengue virus
    Zaytseva, NV
    Montagna, RA
    Lee, EM
    Baeumner, AJ
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) : 46 - 53
  • [33] Development and clinical evaluation of an automated multi-analyte biochip array for rapid stroke diagnosis
    Harte, E.
    CLINICA CHIMICA ACTA, 2019, 493
  • [34] Post-CMOS compatible microfabrication of a multi-analyte bioelectrochemical sensor array microsystem
    Huang, Yue
    Mason, Andrew
    Greiner, Aaron J.
    Ofoli, Robert Y.
    Worden, R. Mark
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 612 - +
  • [35] Multi-analyte biosensor interface for real-time monitoring of 3D microtissue spheroids in hanging-drop networks
    Misun, Patrick M.
    Rothe, Jorg
    Schmid, Yannick R. F.
    Hierlemann, Andreas
    Frey, Olivier
    MICROSYSTEMS & NANOENGINEERING, 2016, 2
  • [36] BioMEMS device with integrated microdialysis probe and biosensor array
    Petrou, PS
    Moser, I
    Jobst, G
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (10): : 859 - 865
  • [37] Fast and simultaneous monitoring of organic pollutants in a drinking water treatment plant by a multi-analyte biosensor followed by LC-MS validation
    Rodriguez-Mozaz, S
    de Alda, MJL
    Barceló, D
    TALANTA, 2006, 69 (02) : 377 - 384
  • [38] Multi-analyte biosensor interface for real-time monitoring of 3D microtissue spheroids in hanging-drop networks
    Patrick M. Misun
    Jörg Rothe
    Yannick R.F. Schmid
    Andreas Hierlemann
    Olivier Frey
    Microsystems & Nanoengineering, 2
  • [39] Accuracy and Feasibility of a Novel Glucose/Lactate Continuous Multi-Analyte Sensing Platform in Humans
    Lu, Jean C.
    Morrison, Dale
    Halim, Bella
    Manos, Georgina
    Obeyesekere, Varuni
    Kannard, Brian
    Shah, Rajiv
    Wolfe, Kate
    Morrow, Blake
    Pagliuso, Ben
    Liang, Bradley
    Nava, Bella
    Lee, Melissa H.
    Ekinci, Elif
    Jenkins, Alicia J.
    Macisaac, Richard J.
    O'Neal, David N.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [40] Design and Analysis of Multi-Analyte Detection Based Biosensor in the Visible to Near-Infrared (VNIR) Region
    Ahmed, Kawsar
    Amin, Ruhul
    Bui, Francis M.
    Chen, Li
    Mohammadd, Noor
    Al-Zahrani, Fahad Ahmed
    Kumar, Santosh
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2024, 23 (01) : 42 - 50