Use of the anterior chamber maintainer in anterior segment surgery

被引:35
|
作者
Chawla, HB
Adams, AD
机构
[1] Princess Alexandra Eye Pavilion, Edinburgh EH3 9HA, Chalmers Street
来源
关键词
D O I
10.1016/S0886-3350(96)80214-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Over a 12 month period, we used the anterior chamber maintainer (ACM) in cataract surgery in 258 patients; ages ranged from 15 to 95 years (mean 73 years). Surgery was performed using general or local anesthesia. The procedures were standard extra-capsular cataract extraction (ECCE), mini-nuc ECCE, vectis extraction of the endonucleus, manual phacofragmentation, phacoemulsification, phacotrabeculectomy, repositioning the IOL, and anterior segment revision. We recorded our subjective assessment of the degree of anterior chamber (AC) maintenance and control of the position of the posterior capsule during surgery. We also kept clinical notes of the practical aspects of the procedures. The AC was well maintained in all patients throughout the surgery; posterior position of the posterior capsule was maintained during irrigation/aspiration. Five patients required the use of a viscoelastic agent at some stage. Our subjective assessment is that use of the ACM increased surgical control of the anterior chamber depth and position of the posterior capsule during surgery. Provided that it is used correctly, the ACM may offer increased safety during anterior segment surgery and require less use of viscoelastic agents.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 50 条
  • [21] Toxic anterior segment syndrome and possible association with ointment in the anterior chamber following cataract surgery
    Werner, L
    Sher, JH
    Taylor, JR
    Mamalis, N
    Nash, WA
    Csordas, JE
    Green, G
    Maziarz, EP
    Liu, XM
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02): : 227 - 235
  • [22] RADICAL ANTERIOR SEGMENT SURGERY FOR EPITHELIAL INVASION OF ANTERIOR-CHAMBER - REPORT OF 3 CASES
    FRIEDMAN, AH
    [J]. TRANSACTIONS AMERICAN ACADEMY OF OPHTHALMOLOGY AND OTOLARYNGOLOGY, 1977, 83 (02): : 216 - 223
  • [23] SURGERY OF ANTERIOR SEGMENT
    SCHREINZER, W
    [J]. ARCHIVES D OPHTALMOLOGIE, 1976, 36 (11): : 785 - 788
  • [24] Implantation of a Staar silicone intraocular lens with the anterior chamber maintainer
    Schipper, I
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (01): : 23 - 26
  • [25] Needle capsulorhexis: The importance of using an anterior chamber maintainer - Reply
    Dada, T
    Sethi, HS
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1249 - 1249
  • [26] ANTERIOR SEGMENT SURGERY
    ROPERHALL, MJ
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1990, 74 (06) : 368 - 369
  • [27] Simcoe cannula as an anterior chamber maintainer for intraocular lens implantation
    Qazi, Zaheer Uddin Aqil
    Ashraf, Khalid Masood
    Siddique, Mustansir
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04): : 650 - 651
  • [28] Trocar anterior chamber maintainer: Will it withstand the "test of time"? Reply
    Narang, Priya
    Agarwal, Amar
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1246 - 1247
  • [29] Blumenthal technique and its modification: The glory of anterior chamber maintainer
    Shroff, Cyrus M.
    Singh, A. K.
    Gupta, Charu
    Shroff, Daraius N.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (01) : 86 - 87
  • [30] Anterior chamber maintainer versus viscoelastic material for IOL implantation
    Schipper, I