Candidates for prostate radioactive seed implantation treated by external beam radiotherapy

被引:0
|
作者
Seung, SK [1 ]
Kroll, S
Wilder, RB
Posner, MD
Roach, M
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Mt Zion Canc Ctr, Davis, CA USA
[3] Univ Calif Davis, Dept Radiat Oncol, Davis, CA USA
来源
CANCER JOURNAL | 1998年 / 4卷 / 03期
关键词
prostate cancer; prostate-specific antigen; I-125; implantation; three-dimensional conformal external beam radiotherapy;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE We report the prostate-specific antigen-based freedom from biochemical failure after conventional and three-dimensional conformal external beam radiotherapy for patients who would have been candidates for I-125 im plantation monotherapy. MATERIALS AND METHODS Patients included in the study were required to have prostate-specific antigen values less than or equal to 20, T stage less than or equal to 2b, and Gleason score sum of 2 to 6. All patients underwent external beam irradiation with curative intent and a minimum follow-up from completion of treatment of at least 1 year. In addition, all patients had to have pretreatment and follow-up prostate-specific antigen measurements and no history of hormonal manipulation, orchiectomy, or radical prostatectomy. A total of 187 patients meeting these criteria were treated between March 1988 and June 1995, and they form the study group for this analysis. Freedom from biochemical failure was defined as prostate-specific antigen value that failed to be maintained at 1 ng/mL or less or an increase in prostate-specific antigen value of 0.5 ng/mL, or more in 1 year even if prostate-specific antigen value was less than 1 ng/mL. RESULTS Among the 187 patients, the median pretreatment prostate-specific antigen value was 7.4 ng/mL (0.3-19.9 ng/mL). The median follow-up was 34 months. Twenty-three percent of patients had a Gleason score sum of 2 to 4, and 77% had a Gleason score sum of 5 to 6. Clinical stages were T1 in 33% and T2 in 67%. One hundred twenty-five patients were treated by conventional external beam radiotherapy with a median dose of 69.5 Gy (60-71 Gy), and 62 patients were treated by three-dimensional conformal external beam radiotherapy with a median dose of 76.4 Gy (71.6-87 Gy). The overall freedom from biochemical failure was 75% at 4 years. Rates of freedom from biochemical failure by pretreatment prostate-specific antigen levels were 91% for prostate-specific antigen value less than or equal to 4 ng/mL, 65% for prostate-specific antigen value > 4 but less than or equal to 10 ng/mL, and 30% for prostate-specific antigen value > 10 ng/mL. Pretreatment prostate-specific antigen value was a statistically significant prognosticator, with lower values associated with favorable freedom from biochemical failure outcome in univariate and multivariate analyses. Conventional versus three-dimensional treatment, T1 versus T2 stage, and Gleason score sum 2 to 4 versus 5 to 6 did not show statistically significant difference in freedom from biochemical failure. CONCLUSIONS Although our overall results after external beam radiotherapy for early-stage prostate cancer patients are less favorable than the best results published for I-125 implantation monotherapy, our results are comparable to those in most other studies with implantation monotherapy. This most likely results from selection bias as well as our stricter definition of freedom from biochemical failure. In addition, for our subset of patients, there was no statistically significant improvement in the 4-year freedom from biochemical failure with the use of higher doses.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 50 条
  • [21] Advances in external beam radiotherapy for prostate cancer
    Davda, Reena
    Al-Abdullah, Alhassan
    Ricketts, Kate
    TRENDS IN UROLOGY & MENS HEALTH, 2016, 7 (04) : 13 - 16
  • [22] External beam radiotherapy for localized prostate cancer
    Yilmaz, Hasan
    Aksu, Gorkem
    Dillioglugil, Ozdal
    ASIAN JOURNAL OF ANDROLOGY, 2015, 17 (06) : 892 - 898
  • [23] Developments in External Beam Radiotherapy for Prostate Cancer
    Lumen, Nicolaas
    Ost, Piet
    Van Praet, Charles
    De Meerleer, Gert
    Villeirs, Geert
    Fonteyne, Valerie
    UROLOGY, 2013, 82 (01) : 5 - 10
  • [24] Curative external beam radiotherapy for prostate carcinoma: Results in 231 patients treated in Lyon
    Gerard, JP
    Xie, CH
    Carrie, C
    Romestaing, P
    Pommier, P
    Mornex, F
    Clippe, S
    Sentenac, I
    Ginestet, C
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1999, 69 (10): : 707 - 711
  • [25] Transperineal gold marker implantation for image-guided external beam radiotherapy of prostate cancer
    Jorgo, Kliton
    Agoston, Peter
    Major, Tibor
    Takacsi-Nagy, Zoltan
    Polgar, Csaba
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 (06) : 452 - 458
  • [26] Salvage Pd-103 seed implantation in the treatment of locally recurrent prostate cancer previously treated with external beam radiation therapy
    Terk, M.
    Lo, K.
    Cesaretti, J.
    Stone, N.
    Stock, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S361 - S361
  • [27] Simulating needle insertion and radioactive seed implantation for prostate brachytherapy
    Alterovitz, R
    Pouliot, J
    Taschereau, R
    Hsu, ICJ
    Goldberg, K
    MEDICINE MEETS VIRTUAL REALITY 11: NEXTMED: HEALTH HORIZON, 2003, 94 : 19 - 25
  • [28] External beam radiotherapy boosts to reduce the impact caused by edema in prostate permanent seed implants
    Yue, Ning
    Mori, Jonathan
    Nath, Ravinder
    Heron, Dwight E.
    Huq, M. Saiful
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (09): : 2267 - 2277
  • [29] External beam radiotherapy boosts to reduce the impacts caused by edema in prostate permanent seed implants
    Yue, N
    Mori, J
    Heron, D
    Huq, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2108 - 2108
  • [30] Urodynamic findings 3 months after radiotherapy in patients treated with conformal external beam radiotherapy for prostate carcinoma
    Do, V
    Choo, R
    DeBoer, G
    Herschorn, S
    Danjoux, C
    Chen, CH
    Barak, I
    BJU INTERNATIONAL, 2002, 90 (01) : 62 - 67