Predicting Neurally Mediated Syncope Based on Pulse Arrival Time: Algorithm Development and Preliminary Results

被引:19
|
作者
Meyer, Christian [1 ]
Morren, Geert [2 ]
Muehlsteff, Jens [2 ]
Heiss, Christian
Lauer, Thomas
Schauerte, Patrick [3 ]
Rassaf, Tienush
Purerfellner, Helmut [4 ]
Kelm, Malte
机构
[1] Univ Dusseldorf, Dept Med, Div Cardiol Pulmonol & Vasc Med, D-40225 Dusseldorf, Germany
[2] Philips Res Europe, Aachen, Germany
[3] Rhein Westfal TH Aachen, Div Cardiol & Pulmonol, Aachen, Germany
[4] Elisabethinen Hosp, Linz, Austria
关键词
autonomic nervous system; neurally mediated syncope; prediction; pulse wave; pulse arrival time; tilt-table testing; VASOVAGAL SYNCOPE; BLOOD-PRESSURE; HEART-RATE; NEUROCARDIOGENIC SYNCOPE; VARIABILITY ANALYSIS; MECHANISMS; HUMANS;
D O I
10.1111/j.1540-8167.2011.02030.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prediction of Neurally Mediated Syncope. Background: Neurally mediated syncope (NMS) is a common disorder that is triggered by orthostatic stress. The circulatory adjustments to orthostatic stress occur just prior to a sudden loss of consciousness. NMS prediction would protect patients from falls or accidents. Methods and Results: Based on simultaneously recorded heart rate (HR) and pulse wave during 70. head-up tilt (HUT) table testing we investigated a syncope warning system. In 14 patients with a history of suspected NMS we tested 2 algorithms based on HR and/or pulse arrival time (PAT). When the cumulative risk exceeded the threshold, which was calculated during the first 2 minutes following the posture change to upright position, a syncope prediction alarm was triggered. All syncopes (n = 7) were detected more than 16 seconds before the onset of dizziness or unconsciousness by using a prediction alarm based on HR and PAT (syncope prediction algorithm 2). No false alarm was generated in patients with negative HUT (n = 7). Syncope prediction was improved by detecting the slope of HR changes as compared with monitoring PAT changes alone (syncope prediction algorithm 1). The duration between the prediction alarm and the occurrence of syncope was 99 +/- 108 seconds. Conclusion: Predicting NMS is feasible by monitoring HR and the onset of the pulse wave at the periphery. This approach might improve NMS management. (J Cardiovasc Electrophysiol, Vol. 22, pp. 1042-1048,
引用
收藏
页码:1042 / 1048
页数:7
相关论文
共 50 条
  • [31] A novel time of arrival estimation algorithm based on energy detector
    Liang X.-L.
    Zhang H.
    Lu T.-T.
    Cui L.
    Aaron Gulliver T.
    Zhang M.
    2016, Science and Engineering Research Support Society (10): : 217 - 242
  • [32] A Chatterbot Based on Genetic Algorithm: Preliminary Results
    Orellana, Cristian
    Tobar, Martin
    Yazan, Jeremy
    Peluffo-Ordonez, D.
    Guachi-Guachi, Lorena
    APPLIED INFORMATICS (ICAI 2021), 2021, 1455 : 3 - 12
  • [33] Joint for time of arrival and direction of arrival estimation algorithm based on the subspace of extended hadamard product
    Ba Bin
    Liu Guo-Chun
    Li Tao
    Lin Yu-Cheng
    Wang Yu
    ACTA PHYSICA SINICA, 2015, 64 (07)
  • [34] TIME AND FREQUENCY-DOMAIN ANALYSES OF HEART-RATE-VARIABILITY DURING ORTHOSTATIC - STRESS IN PATIENTS WITH NEURALLY-MEDIATED SYNCOPE
    MORILLO, CA
    KLEIN, GJ
    JONES, DL
    YEE, R
    AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (12): : 1258 - 1262
  • [35] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [36] Association of adenylate cyclase activity in vasopressor-type neurally mediated syncope based on the α2b-AR gene
    Komiyama, Tomoyoshi
    Ayabe, Kengo
    Orita, Kunzo
    Sasaki, Ayumi
    Kitamura, Yuka
    Matsuzawa, Hideyuki
    Yamashita, Teppei
    Nagata, Eiichiro
    Kanatani, Yasuhiro
    Yoshioka, Koichiro
    PLOS ONE, 2025, 20 (02):
  • [37] BLOOD PRESSURE ESTIMATION FROM PPG-BASED PULSE ARRIVAL TIME
    Villeneuve, Emma
    Anglade, Daniel
    Sandre-ballester, Caroline
    Auclair, Loic
    Fuchs, Olivier
    Blandin, Pierre
    JOURNAL OF HYPERTENSION, 2024, 42
  • [38] Pulsar pulse time-of-arrival compensation based on star light Doppler
    College of Information Science and Engineering, Wuhan University of Science and Technology, Wuhan 430081, China
    不详
    Huazhong Ligong Daxue Xuebao, 1 (129-132):
  • [39] A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
    Polinski, Artur
    Pietrewicz, Michal
    Kocejko, Tomasz
    Bujnowski, Adam
    Ruminski, Jacek
    Wtorek, Jerzy
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5822 - 5825
  • [40] Reliable detection of pulse arrival time for partial discharge location in HV cable based on improved Allen-Bear algorithm
    Sun, Tingxi
    Fang, Yizhi
    Lei, Xiaoyue
    Liu, Ying
    Jiang, Zhibin
    Sun, Kang
    Zhang, Jing
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2021, 21 (06) : 1901 - 1911