Time-resolved QA and brachytherapy applicator commissioning: Towards the clinical implementation

被引:5
|
作者
Fonseca, Gabriel P. [1 ]
Voncken, Robert [1 ]
Hermans, Joep [1 ]
Verhaegen, Frank [1 ]
机构
[1] Maastricht Univ Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
关键词
Applicator commissioning; Imaging panel; Time-resolved QA; DOSE-RATE BRACHYTHERAPY; RING APPLICATORS; UNCERTAINTIES; MULTICENTER;
D O I
10.1016/j.brachy.2021.08.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Brachytherapy has a busy workflow relying on manual steps to ensure accurate delivery of the treatment. Systematic treatment errors have been reported due to faulty equipment, inadequate quality assurance (QA) and applicator commissioning methods. This study describes the use of a novel method, the Iridium Imaging System for QA (IrIS - QA), to automate and improve the applicator commissioning for HDR 192 Ir brachytherapy. METHODS AND MATERIALS: A 3D printed holder attached to an Imaging Panel (IP) has been developed to: (1) acquire a high-definition projection of the applicator using the gamma rays of the 192 Ir source for imaging; (2) Track the source within the applicator verifying in a time-resolved manner the dwell positions and dwell times with a high resolution. Results obtained for two applicator models are described in this manuscript. RESULTS: IrIS-QA is capable of measuring the dwell times with an accuracy better than 0.1 s and interdwell distances with submillimetre precision. The applicators tested in the study showed good agreement between planned and delivered dwell times and positions, with mean and maximum dwell position deviations below 0.5 mm and 1.3 mm, respectively. Dwell time measurements showed agreement superior to 0.05 s except for the first dwell position for which up to 0.15 s differences were observed. CONCLUSIONS: IrIS-QA is a compact system that includes many features necessary to improve the accuracy and efficiency of applicator commissioning and daily QA. No commercial system exists with similar capabilities. IrIS-QA is intended to replace current clinical procedures using film dosimetry. (c) 2021 Published by Elsevier Inc. on behalf of American Brachytherapy Society.
引用
下载
收藏
页码:128 / 137
页数:10
相关论文
共 50 条
  • [1] Time-resolved commissioning of HDR brachytherapy applicators
    Fonseca, G. P.
    Van den Bosch, M. R.
    Voncken, R.
    Podesta, M.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S71 - S72
  • [2] Feasibility of HDR Brachytherapy Applicator Commissioning and QA Using a Mobile CT Scanner
    Stock, M.
    Vinogradskiy, Y.
    Taleei, R.
    MEDICAL PHYSICS, 2022, 49 (06) : E199 - E199
  • [3] Filmless Method for HDR Brachytherapy Applicator Commissioning and Quality Assurance (QA) Using Fluoroscopic Images
    Kang, H.
    Patel, R.
    Mysz, M.
    Roeske, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E242 - E242
  • [4] Commissioning, QA and Clinical Implementation of ExacTrac at RMH, London
    Lamb, C.
    Burke, K.
    Corsini, L.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 271 - 271
  • [5] Clinical Implementation of Electronic Brachytherapy Skin Applicator in IORT Setting
    Kim, C.
    Furhang, E.
    Chadha, M.
    Hu, K.
    Harrison, L.
    MEDICAL PHYSICS, 2010, 37 (06) : 3194 - +
  • [6] Clinical Implementation of New Endometrial Cylinder Applicator for Electronic Brachytherapy
    Cardarelli, G.
    Hiatt, J.
    Curran, B.
    Segala, J.
    Sternick, E.
    Markelewicz, R.
    Hepel, J.
    Puthawala, Y.
    Shioshiansi, S.
    Wazer, D.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Time-resolved in vivo dosimetry for source tracking in brachytherapy
    Johansen, Jacob Graversen
    Rylander, Susanne
    Buus, Simon
    Bentzen, Lise
    Hokland, Steffen Bjerre
    Sondergaard, Christian Skou
    With, Anders Karl Mikael
    Kertzscher, Gustavo
    Tanderup, Kari
    BRACHYTHERAPY, 2018, 17 (01) : 122 - 132
  • [8] Towards time-resolved THz imaging
    P.C.M. Planken
    H.J. Bakker
    Applied Physics A, 2004, 78 : 465 - 469
  • [9] Towards time-resolved THz imaging
    Planken, PCM
    Bakker, HJ
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2004, 78 (04): : 465 - 469
  • [10] Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance
    Barnes, Michael P.
    Greer, Peter B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 220 - 230