Anterior Interbody Fusion of the Cervical Spine with a Zero-P Spacer. Radiographic Results with a Minimum Follow-up of One Year in a Prospective Study

被引:0
|
作者
Vanek, P. [1 ]
Bradac, O. [1 ]
Saur, K. [1 ]
机构
[1] Ustredni Vojenska Nemocn Praha, Neurochirurg Klin, Prague, Czech Republic
关键词
cervical spine; interbody fusion; fusion rate; radiology; stand-alone implant; Zero-P; CARBON-FIBER CAGE; CLOWARD PROCEDURE; BONE; DISKECTOMY; DYSPHAGIA; FIXATION; IMPLANT; DEVICE; RISK;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PURPOSE OF THE STUDY The aim of this study was to compare the efficacy of anterior cervical microdiscectomy and fusion carried out using a newly designed interbody spacer with that of a standard cage plate construct in patients with symptomatic cervical spine spodylosis. The comparison was based on radiographic results and fusion rates. MATERIAL A total number of 113 consecutive patients were enrolled in this prospective study between October 2008 and July 2009. Mono- or bisegmental spondylosis was diagnosed in the patients in whom conservative treatment of cervicobrachial symptoms had had no effect. Patients with myelopathy were not included.. METHODS All patients underwent standard anterior microdiscectomy (at one or two levels). The novel anchored spacer Zero-P was used in 61 patients (group 1) and, in 52 patients, stabilisation was done using the interbody spacer Cornerstone and dynamic plate Premier (group 2). Lateral radiographic views of the cervical spine were obtained before surgery and at 6 weeks, and then at 3, 6 and 12 months after surgery. During follow-up, the cervical spine sagittal alignment (CobbC), segmental angle of the treated levels (CobbS), amount of segmental collapse and fusion rates were measured. RESULTS There was no significant difference in CobbC between the two groups during follow- up (p < 0.051). A significant difference in the first two values of CobbS was found (p < 0.001), but next changes in CobbS were without any difference in either group. The mean degree of interspace collapse was without any significant difference between the groups. The fusion rate was significantly higher in group 1 than group 2 nine months after surgery (p = 0.032), but was the same in both groups at 12 months after surgery (p = 1.0). CONCLUSIONS The anchored spacer Zero-P provides biomechanical stability for the cervical spine similar to the cage and dynamic plate construct. Efforts to improve the cervical stand-alone anterior fusion device and to eliminate disadvantages of plate systems should be studied in larger patient groups with longer follow-ups.
引用
收藏
页码:562 / 567
页数:6
相关论文
共 50 条
  • [41] Clinical adjacent-segment pathology after anterior cervical discectomy and fusion: results after a minimum of 10-year follow-up
    Chung, Jae-Yoon
    Kim, Sung-Kyu
    Jung, Sung-Taek
    Lee, Keun-Bae
    SPINE JOURNAL, 2014, 14 (10): : 2290 - 2298
  • [42] The Efficiency of Zero-profile Implant in Anterior Cervical Discectomy Fusion A Prospective Controlled Long-term Follow-up Study
    Li, Yibing
    Hao, Dingjun
    He, Baorong
    Wang, Xiaodong
    Yan, Liang
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (10): : 398 - 403
  • [43] Anterior cervical discectomy and interbody fusion with porous tantalum implant. Results in a series with long-term follow-up
    Papacci, Fabio
    Rigante, Luigi
    Fernandez, Eduardo
    Meglio, Mario
    Montano, Nicola
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 33 : 159 - 162
  • [44] The Cervical Artery Dissection in Stroke Study (CADISS) - One year follow-up results
    Markus, H. S.
    INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 8 - 8
  • [45] Anterior cervical discectomy and fusion surgery versus total disc replacement: A comparative study with minimum of 10-year follow-up
    Yang, Si-Dong
    Zhu, Yan-Bo
    Yan, Suo-Zhou
    Di, Jun
    Yang, Da-Long
    Ding, Wen-Yuan
    SCIENTIFIC REPORTS, 2017, 7
  • [46] Anterior cervical discectomy and fusion surgery versus total disc replacement: A comparative study with minimum of 10-year follow-up
    Si-Dong Yang
    Yan-Bo Zhu
    Suo-Zhou Yan
    Jun Di
    Da-Long Yang
    Wen-Yuan Ding
    Scientific Reports, 7
  • [47] Two-Level Anterior Lumbar Interbody Fusion With Percutaneous Pedicle Screw Fixation: A Minimum 3-Year Follow-up Study Commentary
    Heller, Joshua E.
    Loftus, Christopher M.
    NEUROLOGIA MEDICO-CHIRURGICA, 2010, 50 (08) : 649 - 650
  • [48] Transforaminal lumbar interbody fusion (TLIF) and instruments. Prospective study with the minimum of 20-month follow-up
    Vanek, P.
    Saur, K.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2007, 70 (05) : 552 - 557
  • [49] Modic changes in the cervical spine: Prospective 20-year follow-up study in asymptomatic subjects
    Tsuji, Takashi
    Fujiwara, Hirokazu
    Nishiwaki, Yuji
    Daimon, Kenshi
    Okada, Eijiro
    Nojiri, Kenya
    Watanabe, Masahiko
    Katoh, Hiroyuki
    Shimizu, Kentaro
    Ishihama, Hiroko
    Fujita, Nobuyuki
    Nakamura, Masaya
    Matsumoto, Morio
    Watanabe, Kota
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (04) : 612 - 617
  • [50] Prospective, Randomized Comparison of Cervical Total Disk Replacement Versus Anterior Cervical Fusion Results at 48 Months Follow-up
    Hisey, Michael S.
    Bae, Hyun W.
    Davis, Reginald J.
    Gaede, Steven
    Hoffman, Greg
    Kim, Kee D.
    Nunley, Pierce D.
    Peterson, Daniel
    Rashbaum, Ralph F.
    Stokes, John
    Ohnmeiss, Donna D.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (04): : E237 - E243