Factors influencing the total procedure time of CT-guided percutaneous core-needle biopsies of lung nodules: a retrospective analysis

被引:0
|
作者
Sargent, Tyler [1 ]
Kolderman, Nathan [2 ]
Nair, Girish B. [3 ]
Jankowski, Michelle [1 ]
Al-Katib, Sayf [2 ]
机构
[1] Oakland Univ, William Beaumont Sch Med, Rochester, MI 48063 USA
[2] Beaumont Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USA
[3] Beaumont Hlth Syst, Div Pulm Crit Care, Royal Oak, MI USA
关键词
PULMONARY NODULES; ASPIRATION BIOPSY; RISK-FACTORS; PNEUMOTHORAX; ANGLE; MM;
D O I
10.5152/dir.2022.20731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE This study aims to investigate the factors that influence total procedure time when performing computed tomography (CT)-guided percutaneous core-needle lung biopsies. METHODS This is a cross-sectional study of 673 patients, who underwent a CT-guided percutaneous coreneedle biopsy at a tertiary care center from March 2014 to August 2016. Data on patient, nodule, and procedural factors and outcomes were collected retrospectively. Univariate linear regression and a multivariate stepwise linear regression were utilized for analysis. RESULTS Factors most strongly associated with prolonged procedure duration include 20-gauge needle use when compared with 18-gauge needle use (estimated difference in time = 1.19), collecting additional core biopsies (estimated difference in time = 1.10), decubitus nodule side up (DNSU; estimated difference in time = 1.42), and supine positioning (estimated difference in time = 1.16) relative to decubitus nodule side down positioning, and increased nodule distance from the skin surface (estimated difference in time = 1.03). Increased nodule length (estimated difference in time = 0.93) was associated with reductions in procedure duration. Prolonged procedure time was associated with an increased rate of pneumothorax (odds ratio (OR) = 1.02; P <.0001) and decreased rate of pulmonary hemorrhage (OR = 0.97; P <.0001). CONCLUSION The use of 20-gauge biopsy needle, collecting additional core biopsies, DNSU and supine positioning, smaller nodule size, and increasing nodule distance from the skin surface were associated with increased procedure time for CT-guided core needle biopsies of lung nodules. Prolonged procedure time is associated with a higher rate of pneumothorax and a lower rate of pulmonary hemorrhage.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [41] Safety and accuracy of aortic and periaortic CT-guided percutaneous core needle biopsy
    Marika A. Pitot
    Chris N. Gu
    Daniel A. Adamo
    Anil Nicholas Kurup
    John J. Schmitz
    Annie T. Packard
    Abdominal Radiology, 2023, 48 : 2148 - 2156
  • [42] CT-guided core needle biopsies of head and neck tumors: a comprehensive monocenter analysis of safety and outcomes
    Vogl, Thomas Joseph
    Ketelsen, Heinrich Johannes
    Mahmoudi, Scherwin
    Scholtz, Jan-Erik
    Koch, Vitali
    Gruenewald, Leon David
    Wild, Peter
    Stoever, Timo
    Bernatz, Simon
    EUROPEAN RADIOLOGY, 2024, 34 (8) : 5370 - 5378
  • [43] CT-guided Core-Needle Biopsy of the Lung Is Safe and More Effective than Fine-Needle Aspiration Biopsy in Patients with Hematologic Malignancies
    Watane, Gaurav, V
    Hammer, Mark M.
    Barile, Maria F.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2019, 1 (05):
  • [44] FAILURE FACTORS IN CT-GUIDED BIOPSY OF LUNG LESIONS - ANALYSIS OF 103 CONSECUTIVE BIOPSIES
    GUESSOUS, K
    ARRIVE, L
    NAJMARK, D
    ZINS, M
    GROUSSARD, O
    JOURNAL DE RADIOLOGIE, 1995, 76 (04): : 201 - 204
  • [45] RISK FACTORS OF CT-GUIDED PERCUTANEOUS LUNG BIOPSY COMPLICATIONS
    倪颖梦
    时国朝
    万欢英
    陈克敏
    吴达明
    MedicalBulletinofShanghaiJiaotongUniversity, 2012, 24 (02) : 33 - 41
  • [46] Bilateral CT-guided core needle lung biopsy in a lung cancer patient performed in a single interventional diagnostic procedure
    Gorospe, L.
    Gomez-Bermejo, M. A.
    Ventura-Diaz, S.
    Mirambeaux-Villalona, R. M.
    Caminoa-Lizarralde-Aiza, A.
    Paredes-Rodriguez, P.
    PULMONOLOGY, 2023, 29 : S96 - S98
  • [47] PEDIATRIC SOFT TISSUE AND BONE TUMORS: DETERMINISTIC FACTORS FOR SAFETY AND ACCURACY OF IMAGE-GUIDED PERCUTANEOUS CORE-NEEDLE BIOPSIES
    Shaikh, R.
    PEDIATRIC BLOOD & CANCER, 2013, 60 : 144 - 144
  • [48] Effectiveness of CT-guided percutaneous biopsies of the spine: An analysis of 202 examinations
    Heyer, Christoph M.
    Al-Hadari, Abdulgani
    Mueller, Klaus-Michael
    Stachon, Axel
    Nicolas, Volkmar
    ACADEMIC RADIOLOGY, 2008, 15 (07) : 901 - 911
  • [49] CT-guided transthoracic core needle biopsies of focal pleural lesions smaller than 10 mm: a retrospective study
    Melita Kukuljan
    Ena Mršić
    Eduard Oštarijaš
    Cancer Imaging, 23
  • [50] CT-guided transthoracic core needle biopsies of focal pleural lesions smaller than 10 mm: a retrospective study
    Kukuljan, Melita
    Mrsic, Ena
    Ostarijas, Eduard
    CANCER IMAGING, 2023, 23 (01)