Factors influencing the total procedure time of CT-guided percutaneous core-needle biopsies of lung nodules: a retrospective analysis

被引:0
|
作者
Sargent, Tyler [1 ]
Kolderman, Nathan [2 ]
Nair, Girish B. [3 ]
Jankowski, Michelle [1 ]
Al-Katib, Sayf [2 ]
机构
[1] Oakland Univ, William Beaumont Sch Med, Rochester, MI 48063 USA
[2] Beaumont Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USA
[3] Beaumont Hlth Syst, Div Pulm Crit Care, Royal Oak, MI USA
关键词
PULMONARY NODULES; ASPIRATION BIOPSY; RISK-FACTORS; PNEUMOTHORAX; ANGLE; MM;
D O I
10.5152/dir.2022.20731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE This study aims to investigate the factors that influence total procedure time when performing computed tomography (CT)-guided percutaneous core-needle lung biopsies. METHODS This is a cross-sectional study of 673 patients, who underwent a CT-guided percutaneous coreneedle biopsy at a tertiary care center from March 2014 to August 2016. Data on patient, nodule, and procedural factors and outcomes were collected retrospectively. Univariate linear regression and a multivariate stepwise linear regression were utilized for analysis. RESULTS Factors most strongly associated with prolonged procedure duration include 20-gauge needle use when compared with 18-gauge needle use (estimated difference in time = 1.19), collecting additional core biopsies (estimated difference in time = 1.10), decubitus nodule side up (DNSU; estimated difference in time = 1.42), and supine positioning (estimated difference in time = 1.16) relative to decubitus nodule side down positioning, and increased nodule distance from the skin surface (estimated difference in time = 1.03). Increased nodule length (estimated difference in time = 0.93) was associated with reductions in procedure duration. Prolonged procedure time was associated with an increased rate of pneumothorax (odds ratio (OR) = 1.02; P <.0001) and decreased rate of pulmonary hemorrhage (OR = 0.97; P <.0001). CONCLUSION The use of 20-gauge biopsy needle, collecting additional core biopsies, DNSU and supine positioning, smaller nodule size, and increasing nodule distance from the skin surface were associated with increased procedure time for CT-guided core needle biopsies of lung nodules. Prolonged procedure time is associated with a higher rate of pneumothorax and a lower rate of pulmonary hemorrhage.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [1] Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions
    Mills, M.
    Choi, J.
    El-Haddad, G.
    Sweeney, J.
    Biebel, B.
    Robinson, L.
    Antonia, S.
    Kumar, A.
    Kis, B.
    CLINICAL RADIOLOGY, 2017, 72 (12) : 1038 - 1046
  • [2] CT-guided core-needle biopsy in omental pathology
    Pombo, F
    Rodriguez, E
    Martin, R
    Lago, M
    ACTA RADIOLOGICA, 1997, 38 (06) : 978 - 981
  • [3] CT-guided percutaneous needle biopsy of small lung nodules in children
    B. L. Connolly
    Peter G. Chait
    David S. Duncan
    Glenn Taylor
    Pediatric Radiology, 1999, 29 : 342 - 346
  • [4] CT-guided percutaneous needle biopsy of small lung nodules in children
    Connolly, BL
    Chait, PG
    Duncan, DS
    Taylor, G
    PEDIATRIC RADIOLOGY, 1999, 29 (05) : 342 - 346
  • [5] Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions
    Michel Montaudon
    Valerie Latrabe
    Antoine Pariente
    Olivier Corneloup
    Hugues Begueret
    François Laurent
    European Radiology, 2004, 14 : 1234 - 1240
  • [6] Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions
    Montaudon, M
    Latrabe, V
    Pariente, A
    Corneloup, O
    Begueret, H
    Laurent, F
    EUROPEAN RADIOLOGY, 2004, 14 (07) : 1234 - 1240
  • [7] Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions
    Li, Y.
    Du, Y.
    Luo, T. Y.
    Yang, H. F.
    Yu, J. H.
    Xu, X. X.
    Zheng, H. J.
    Li, B.
    CLINICAL RADIOLOGY, 2014, 69 (01) : E43 - E47
  • [8] Factors that contribute to false-negative results in CT-guided transthoracic lung core-needle biopsy
    Sun, Daqian
    Yao, Tianxiao
    Wang, Lixin
    Ma, Shengmei
    Gao, Min
    Li, Jingshuo
    Li, Chunhai
    Xu, Lisheng
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (01) : 86 - 91
  • [9] CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma
    Sklair-Levy, M
    Polliack, A
    Shaham, D
    Applbaum, YH
    Gillis, S
    Ben-Yehuda, D
    Sherman, Y
    Libson, E
    EUROPEAN RADIOLOGY, 2000, 10 (05) : 714 - 718
  • [10] Real-Time Histologic Assessment of CT-Guided Percutaneous Needle Core Biopsies of the Transplant Pancreas
    Wilcox, R.
    Bhave, A. D.
    Gibson, P.