Pulmonary nodule registration: Rigid or nonrigid?

被引:12
|
作者
Gu, Suicheng [1 ]
Wilson, David [2 ]
Tan, Jun [1 ]
Pu, Jiantao [1 ,3 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Med, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
pulmonary nodule; rigid/nonrigid registration; Demons algorithm; follow-up study; DEFORMABLE REGISTRATION; LUNG REGISTRATION; SURFACES; CHEST;
D O I
10.1118/1.3602457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The primary aim of this study is to investigate the performance difference of rigid and nonrigid registration schemes in matching corresponding pulmonary nodules depicted on sequential chest computed tomography (CT) examinations. Methods: A gradient descent based rigid registration algorithm with scaling was developed and it handled the involved geometric transformations (i.e., translation, rescaling, shearing, and rotation) separately instead of optimizing them in a single pass. Given two lung CT examinations, the scaling and translation parameters were simply estimated from the lung volume dimensions (e.g., size and mass center), while the rotation parameters were optimized progressively using gradient descent. To investigate the performance difference of rigid and nonrigid schemes in pulmonary nodule registration, the well-known nonrigid Demons algorithm was implemented and tested along with the developed schemes against 60 diverse low-dose clinical lung CT examinations with average 2-yr follow-up scans. A verified cancer and its correspondence in the follow-up scan as well as their spatial locations (mass center) were identified in each examination. In addition to the computational efficiency, the accuracy of these registration procedures was assessed by computing the Euclidean distances between the corresponding nodules after the registration. To demonstrate the advantage of the developed algorithm, the authors also implemented a fast iterative closest point (ICP) based rigid algorithm and compared their performance. Results: Our experiments on the collected chest CT examinations showed that the nodule registration errors in 3D Euclidean distance for the developed rigid affine approach, the traditional ICP algorithm, and the refining nonrigid Demons algorithm were 9.6, 9.8, and 10.0 mm, respectively, and the corresponding computational costs in time were 5, 300, and 55 s, respectively. Conclusions: A rigid solution may be preferred in practice for the pulmonary nodule registration in longitudinal studies because of its relatively high efficiency and sufficient accuracy for the clinical need. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3602457]
引用
收藏
页码:4406 / 4414
页数:9
相关论文
共 50 条
  • [11] Nonrigid multimodality image registration
    Mattes, D
    Haynor, DR
    Vesselle, H
    Lewellen, TK
    Eubank, W
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1609 - 1620
  • [12] Image Registration Algorithm for Sequence Pathology Slices Of Pulmonary Nodule
    Liu, Qianqian
    Zhao, Gaofeng
    Deng, Jicai
    Xue, Qi
    Hou, Weiyan
    He, Yingzhe
    2019 8TH INTERNATIONAL SYMPOSIUM ON NEXT GENERATION ELECTRONICS (ISNE), 2019,
  • [13] Noninvasive Pulmonary Nodule Elastometry by CT and Deformable Image Registration
    Negahdar, M.
    Shultz, D. B.
    Eyben, R. V.
    Fasola, C.
    Yu, A. S.
    Tian, L.
    Fleischmann, D.
    Gable, L.
    Shan, X.
    Diehn, M.
    Loo, B. W.
    Maxim, P. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S10 - S10
  • [14] Noninvasive Pulmonary Nodule Elastometry by CT and Deformable Image Registration
    Negahdar, M.
    Shultz, D. B.
    Eyben, R. V.
    Fasola, C.
    Yu, A. S.
    Tian, L.
    Fleischmann, D.
    Gable, L.
    Shan, X.
    Diehn, M.
    Loo, B. W.
    Maxim, P. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S623 - S624
  • [15] Noninvasive pulmonary nodule elastometry by CT and deformable image registration
    Negandar, Mohammadreza
    Fasola, Carolina E.
    Yu, Amy S.
    von Eyben, Rie
    Yamamoto, Tokihiro
    Diehn, Maximilian
    Fleischmann, Dominik
    Tian, Lu
    Loo, Billy W.
    Maxim, Peter G.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 (01) : 35 - 40
  • [16] Pulmonary nodule registration in serial CT scans based on rib anatomy and nodule template matching
    Shi, Jiazheng
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir
    Zhou, Chuan
    Cascade, Philip N.
    Bogot, Naama
    Kazerooni, Ella A.
    Wu, Yi-Ta
    Wei, Jun
    MEDICAL PHYSICS, 2007, 34 (04) : 1336 - 1347
  • [17] Pulmonary nodule registration in serial CT scans using rib anatomy and nodule template matching
    Shi, Jiazheng
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir
    Zhou, Chuan
    Wu, Yi-Ta
    Wei, Jun
    MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
  • [18] A rigidity penalty term for nonrigid registration
    Staring, Marius
    Klein, Stefan
    Pluim, Josien P. W.
    MEDICAL PHYSICS, 2007, 34 (11) : 4098 - 4108
  • [19] A TOPOLOGICAL FEATURE CONSTRAINT FOR NONRIGID REGISTRATION
    Lin, Xiang-Bo
    Wang, Xin-Ning
    2014 IEEE CHINA SUMMIT & INTERNATIONAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (CHINASIP), 2014, : 399 - 402
  • [20] Pulmonary nodule registration in serial CT scans using global rib matching and nodule template matching
    Jo, Hyun Hee
    Hong, Helen
    Goo, Jin Mo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 45 : 87 - 97