A high rate gaseous area detector for X-ray diffraction applications

被引:0
|
作者
Khazins, DM [1 ]
Becker, BL [1 ]
He, BB [1 ]
Diawara, Y [1 ]
Durst, RD [1 ]
Medved, SA [1 ]
Sedov, V [1 ]
Thorson, TA [1 ]
机构
[1] Bruker AXS Inc, Madison, WI 53711 USA
关键词
sealed gaseous detector; X-ray diffraction; photon counting; x-ray detector;
D O I
10.1117/12.505184
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new photon-counting area detector based on parallel-plate gas amplification with a resistive anode and remote readout electrode is described. The detector is sealed and has a sensitive area of 14x14 cm(2). The detector is unique in its ability to achieve high gain at high counting rates. A local counting rate >10(5) counts/mm(2)-sec has been achieved at a gain of up to 10(5) in a radiation-hard, non-polymerizing gas mixture. The global readout rate is limited by the delay line and electronics to <10(6) counts/sec but more sophisticated readout schemes should allow this rate to be increased by more than an order of magnitude. The operating characteristics of the detector are described and preliminary x-ray diffraction data is presented.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 50 条
  • [31] Application of a pnCCD in X-ray diffraction:: a three-dimensional X-ray detector
    Leitenberger, Wolfram
    Hartmann, Robert
    Pietsch, Ullrich
    Andritschke, Robert
    Starke, Ines
    Strueder, Lothar
    JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 (05) : 449 - 457
  • [32] Characterization of TlBr for X-ray and γ-ray detector applications
    Kostamo, P.
    Shorohov, M.
    Gostilo, V.
    Sipila, H.
    Kozlov, V.
    Lisitsky, I.
    Kuznetsov, M.
    Lankinen, A.
    Danilewsky, A. N.
    Lipsanen, H.
    Leskela, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 129 - 131
  • [33] Large area, low capacitance Si(Li) detectors for high rate x-ray applications
    Rossington, C.S.
    Fine, P.M.
    Madden, N.W.
    IEEE Transactions on Nuclear Science, 1993, 40 (4 pt 1) : 354 - 359
  • [34] High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector
    Imai, Yasuhiko
    Kimura, Shigeru
    Sakata, Osami
    Sakaia, Akira
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 30 - +
  • [35] A diffraction effect in X-ray area detectors
    Gollwitzer, C. (christian.gollwitzer@ptb.de), 1600, International Union of Crystallography, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (47):
  • [36] A diffraction effect in X-ray area detectors
    Gollwitzer, Christian
    Krumrey, Michael
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 378 - 383
  • [37] New detector for fast X-ray diffraction measurements
    不详
    ZKG INTERNATIONAL, 2005, 58 (10): : 26 - 26
  • [38] Scanning CCD Detector for X-ray Powder Diffraction
    Madden, T.
    Baldwin, J.
    Von Dreele, R.
    Suchomel, M.
    Toby, B. H.
    17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [39] Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications
    Vernon, Emerson
    De Geronimo, Gianluigi
    Baldwin, Jonathan
    Chen, Wei
    Fried, Jack
    Giacomini, Gabriele
    Kuczewski, Anthony
    Kuczewski, John
    Mead, Joe
    Miceli, Antonino
    Okasinski, John S.
    Pinelli, Don
    Quaranta, Orlando
    Rumaiz, Abdul K.
    Siddons, Peter
    Smith, Graham
    Stanacevic, Milutin
    Woods, Russell
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (04) : 752 - 759
  • [40] APPLICATIONS OF X-RAY AREA DETECTORS
    ARNDT, UW
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C405 - C405