Towards development of an intravascular diagnostic catheter based on fluorescence lifetime spectroscopy: Study of an optimized blood flushing system

被引:1
|
作者
Ghata, Narugopal [1 ,3 ]
Aldredge, Ralph C. [1 ]
Bec, Julien [2 ]
Marcu, Laura [2 ]
机构
[1] Univ Calif Davis, Dept Mech & Aerosp Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] ANSYS Inc, Berkeley, CA 94705 USA
来源
关键词
Catheter; Turbulence model; Mixing model; ATHEROSCLEROTIC PLAQUES;
D O I
10.1117/12.874957
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fluorescence lifetime spectroscopy has demonstrated potential for characterization and diagnosis of arterial vessels pathologies. However, the intravascular application of such technique is hampered by the presence of blood hemoglobin that affects both the delivery of the excitation light to and the collection of the fluorescence light from the vessel wall. We report here a computational fluid dynamics model that allows for the optimization of blood flushing parameters in a manner that minimizes the amount of saline needed to clear the optical field of view. A 3D turbulence (k - epsilon) model was employed to simulate the flow inside and around a side-viewing fiber-optic catheter. The influence of various infusion rates, blood flow rates and vessel diameters on the flow around the catheter tip and its effects on the wall shear stress (WSS) are studied. Current results suggest that low flushing rates in smaller-diameter vessels (e.g., stenotic vessels) can produce better flushing efficiency by removing the blood cells in the path of the fluorescence light and reducing wall shear stress. The comparison of the results for blood vessels with equal diameter but different flow rates suggests that the effect of systolic and diastolic conditions on the maximum wall shear stress is not substantial. The results from this study can be utilized in determining the optimal flushing rate depending on the diameter of the vessels, blood flow rate, and the maximum wall shear stress that vessel wall can sustain, which can be estimated from the feedback of the fluorescent light from the wall.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Towards the Development of a Closed, Nanofiber-Based Culture System for Clinical Expansion of Cord Blood-Derived CD34+Cells
    Fischer, Stephen E.
    Ma, Yiwei
    Smith, Caitlin
    Sodha, Anirudhasingh
    Zhao, Yukang
    BLOOD, 2012, 120 (21)
  • [42] Smartphone-based spectral imaging otoscope: System development and preliminary study for evaluation of its potential as a mobile diagnostic tool
    Cavalcanti, Thiago C.
    Kim, Sewoong
    Lee, Kyungsu
    Lee, Sang-Yeon
    Park, Moo Kyun
    Hwang, Jae Youn
    JOURNAL OF BIOPHOTONICS, 2020, 13 (06)
  • [43] Towards Development of LED-Based Time-Domain Near-IR Spectroscopy System for Delineating Breast Cancer From Adjacent Normal Tissue
    Kamal, Arif Mohd.
    Pal, Uttam M.
    Nayak, Ashika
    Medisetti, Tejaswi
    Arjun, B. S.
    Pandya, Hardik J.
    IEEE SENSORS JOURNAL, 2021, 21 (16) : 17758 - 17765
  • [44] Development and validation of a feature extraction- based logical anthropomorphic diagnostic system for early gastric cancer: A case-control study
    Li, Jia
    Zhu, Yijie
    Dong, Zehua
    He, Xinqi
    Xu, Ming
    Liu, Jun
    Zhang, Mengjiao
    Tao, Xiao
    Du, Hongliu
    Chen, Di
    Huang, Li
    Shang, Renduo
    Zhang, Lihui
    Luo, Renquan
    Zhou, Wei
    Deng, Yunchao
    Huang, Xu
    Li, Yanxia
    Chen, Boru
    Gong, Rongrong
    Zhang, Chenxia
    Li, Xun
    Wu, Lianlian
    Yu, Honggang
    ECLINICALMEDICINE, 2022, 46
  • [45] Optimized model for coordinated development of regional sustainable agriculture based on water-energy-land-carbon nexus system: A case study of Sichuan Province
    Feng, Tingting
    Liu, Bin
    Ren, Hourui
    Yang, Jingjing
    Zhou, Zhongli
    ENERGY CONVERSION AND MANAGEMENT, 2023, 291
  • [46] A Natural Language Processing-Based Virtual Patient Simulator and Intelligent Tutoring System for the Clinical Diagnostic Process: Simulator Development and Case Study
    Furlan, Raffaello
    Gatti, Mauro
    Mene, Roberto
    Shiffer, Dana
    Marchiori, Chiara
    Levra, Alessandro Giaj
    Saturnino, Vincenzo
    Brunetta, Enrico
    Dipaola, Franca
    JMIR MEDICAL INFORMATICS, 2021, 9 (04)
  • [47] Study on measurement of nanoparticles size based on fluorescence polarization (1st Report) - Development of rotational diffusion coefficient measurement system using fluorescent DNA probe - Development o
    Ishizaki, Yuki
    Hayashi, Terutake
    Michihata, Masaki
    Takaya, Yasuhiro
    1600, Japan Society for Precision Engineering (80): : 214 - 219
  • [48] Towards universal health coverage: a mixed-method study mapping the development of the faith-based non-profit sector in the Ghanaian health system
    Grieve, Annabel
    Olivier, Jill
    INTERNATIONAL JOURNAL FOR EQUITY IN HEALTH, 2018, 17
  • [49] Towards universal health coverage: a mixed-method study mapping the development of the faith-based non-profit sector in the Ghanaian health system
    Annabel Grieve
    Jill Olivier
    International Journal for Equity in Health, 17
  • [50] Development of a COVID-19 early risk assessment system based on multiple machine learning algorithms and routine blood tests: a real-world study
    Qin, Qiangqiang
    Li, Qingxuan
    Zhu, Guiyin
    Yu, Haiyang
    Peng, Mingyan
    Wu, Shuang
    Xu, Xue
    Gu, Wen
    Guo, Xuejun
    FRONTIERS IN IMMUNOLOGY, 2024, 15