Towards development of an intravascular diagnostic catheter based on fluorescence lifetime spectroscopy: Study of an optimized blood flushing system

被引:1
|
作者
Ghata, Narugopal [1 ,3 ]
Aldredge, Ralph C. [1 ]
Bec, Julien [2 ]
Marcu, Laura [2 ]
机构
[1] Univ Calif Davis, Dept Mech & Aerosp Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] ANSYS Inc, Berkeley, CA 94705 USA
来源
关键词
Catheter; Turbulence model; Mixing model; ATHEROSCLEROTIC PLAQUES;
D O I
10.1117/12.874957
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fluorescence lifetime spectroscopy has demonstrated potential for characterization and diagnosis of arterial vessels pathologies. However, the intravascular application of such technique is hampered by the presence of blood hemoglobin that affects both the delivery of the excitation light to and the collection of the fluorescence light from the vessel wall. We report here a computational fluid dynamics model that allows for the optimization of blood flushing parameters in a manner that minimizes the amount of saline needed to clear the optical field of view. A 3D turbulence (k - epsilon) model was employed to simulate the flow inside and around a side-viewing fiber-optic catheter. The influence of various infusion rates, blood flow rates and vessel diameters on the flow around the catheter tip and its effects on the wall shear stress (WSS) are studied. Current results suggest that low flushing rates in smaller-diameter vessels (e.g., stenotic vessels) can produce better flushing efficiency by removing the blood cells in the path of the fluorescence light and reducing wall shear stress. The comparison of the results for blood vessels with equal diameter but different flow rates suggests that the effect of systolic and diastolic conditions on the maximum wall shear stress is not substantial. The results from this study can be utilized in determining the optimal flushing rate depending on the diameter of the vessels, blood flow rate, and the maximum wall shear stress that vessel wall can sustain, which can be estimated from the feedback of the fluorescent light from the wall.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Design, construction and validation of a multimodal intravascular diagnostic catheter combining IVUS and fluorescence lifetime spectroscopy detection channels
    Bec, Julien
    Xi, Hongtao
    Yankelevich, Diego
    Zhou, Feifei
    Sun, Yang
    Ghata, Narugopal
    Aldredge, Ralph
    Marcu, Laura
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883
  • [2] Computational analysis of the effectiveness of blood flushing with saline injection from an intravascular diagnostic catheter
    Ghata, Narugopal
    Aldredge, Ralph C.
    Bec, Julien
    Marcu, Laura
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (11) : 1278 - 1293
  • [3] Design, construction, and validation of a rotary multifunctional intravascular diagnostic catheter combining multispectral fluorescence lifetime imaging and intravascular ultrasound
    Bec, Julien
    Xie, Hongtao
    Yankelevich, Diego R.
    Zhou, Feifei
    Sun, Yang
    Ghata, Narugopal
    Aldredge, Ralph
    Marcu, Laura
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)
  • [4] Assembly and characterization of a fluorescence lifetime spectroscopy system for skin lesions diagnostic
    Nogueira, Marcelo Saito
    Teixeira Rosa, Ramon Gabriel
    Pratavieira, Sebastiao
    D'Almeida, Camila de Paula
    Kurachi, Cristina
    BIOPHOTONICS SOUTH AMERICA, 2015, 9531
  • [5] Development of a Fluorescence Lifetime Spectroscopy System with Multicolor-Excitation
    Preegarn, Jakgree
    Sapermsap, Natakorn
    Sangtawesin, Sorawis
    19TH SIAM PHYSICS CONGRESS, 2025, 2934
  • [6] Dual-modality fluorescence lifetime imaging-optical coherence tomography intravascular catheter system with freeform catheter optics
    Li, Cai
    Bec, Julien
    Zhou, Xiangnan
    Marcu, Laura
    JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (07)
  • [7] Development of a Multi-modal Tissue Diagnostic System Combining High Frequency Ultrasound and Photoacoustic Imaging with Lifetime Fluorescence Spectroscopy
    Sun, Yang
    Stephens, Douglas N.
    Park, Jesung
    Sun, Yinghua
    Marcu, Laura
    Cannata, Jonathan M.
    Shung, K. Kirk
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 570 - +
  • [8] Development and quantification of a novel intravascular catheter-based radionuclide imaging system
    Zaman, Raiyan
    Carpenter, Colin
    Pratx, Guillem
    Sun, Conroy
    Xing, Lei
    McConnell, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [9] Dual modality intravascular catheter system combining pulse-sampling fluorescence lifetime imaging and polarization-sensitive optical coherence tomography
    Bec, Julien
    Zhou, Xiangnan
    Villiger, Martin
    Southard, Jeffrey A.
    Bouma, Brett
    Marcu, Laura
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (04): : 2114 - 2132
  • [10] Development of Diagnostic System for Atherosclerosis based on Intrinsic Fluorescence using Multispectral Imaging
    Ho, C.
    Horiuchi, T.
    Taniguchi, H.
    Umetsu, A.
    Hagisawa, K.
    Iwaya, K.
    Azmi, A.
    Zulaziz, N.
    Azhim, A.
    Shinomiya, N.
    Morimoto, Y.
    2015 10TH ASIAN CONTROL CONFERENCE (ASCC), 2015,