Effect of inlet/outlet on thermal performance of naturally ventilated building

被引:5
|
作者
Maher, Dhahri [1 ,3 ]
Hana, Aouinet [2 ]
Arjmand, Jamal Tabe [4 ]
Issakhov, Alibek [5 ]
Sammouda, Habib [3 ]
Sheremet, Mikhail [6 ,7 ]
Sharma, Shubham [8 ]
机构
[1] Univ Sousse, Higher Inst Agr Sci Chott Mariem, BP 47, Sousse 4042, Tunisia
[2] Univ Tunis El Manar, Natl Engn Sch Tunis, Civil Dept, Tunis 1002, Tunisia
[3] Sousse Univ, High Sch Sci & Technol Hammam Sousse, Lab Energy & Mat LabEM LR11ES34, BP 4011, Hammam Sousse, Tunisia
[4] Univ Art, Fac Architecture & Urban Planning, Tehran 1136813518, Iran
[5] Al Farabi Kazakh Natl Univ, Fac Mech & Math, Dept Math & Comp Modelling, Alma Ata 05000005006, Kazakhstan
[6] Tomsk State Univ, Lab Convect Heat & Mass Transfer, Tomsk 634050, Russia
[7] Tomsk State Univ, Dept Theoret Mech, Tomsk 634050, Russia
[8] IK Gujral Punjab Tech Univ, Dept Mech Engn, Main Campus, Kapurthala 144603, India
关键词
building; ventilation; comfort; computational fluid dynamic; PREDICTING AIR-FLOW; ENCLOSED ENVIRONMENTS; CROSS-VENTILATION; TURBULENCE MODELS; CFD; CONDUCTIVITY; SIMULATION; IMPACT;
D O I
10.1093/ijlct/ctab055
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ventilation is a way of improving the air quality of rooms by circulation. The position of the inlet and outlet greatly influences the thermal comfort. This attempt proposes to analyse the effect of the position of window openings for a room building with natural ventilation and the air flow and temperature distribution numerically using a commercial computational fluid dynamics (CFD) code. This proposed study consists of (i) approving the numerical model against experimental data gathered in an environment similar to the one used in simulations and (ii) applying the CFD model to explore the results of four varying configurations of ventilator on the natural ventilation system and thermal comfort. For the varying arrangements, the wind speed is 0.2 m.s(-1) perpendicular to the openings for a wind, (iii) evaluating the comfort level utilizing the Air Diffusion Performance Index (ADPI) on the basis of ASHRAE 55-210 criteria. The obtained results show that the positions of outlet and inlet openings highly affect the performance in the thermal comfort while they have a trivial effect on the occupied zone mean velocity. The computational results showed that the two cases (a) and (b) present results very close to each other with a slight difference at the center of the chamber. Most of the calculated values (effective draft temperature, EDT) are between (-1.7 and 1.1). Then ADPI is over 70% for case (a) and over 75% for case (b), so all points they are located in the comfort zone. The results affirmed also that configuration with inlet openings set at 1.022 m above ground and an outlet opening set at 0.52 m brings about the most applicable solution ventilation efficiency and give the best EDT that fulfills the criteria of ASHRAE 55-210 with an ADPI of similar to 90%.
引用
收藏
页码:1348 / 1362
页数:15
相关论文
共 50 条
  • [21] Performance of lightweight and heavyweight building walls with naturally ventilated passive and active facades
    Rahiminejad, Mohammad
    Paris, Alexandre Louis Marie
    Ge, Hua
    Khovalyg, Dolaana
    ENERGY AND BUILDINGS, 2022, 256
  • [22] Effect of inlet and outlet location on the mixed convective cooling inside the ventilated cavity subjected to an external nanofluid
    Mahmoudi, Amir Houshang
    Shahi, Mina
    Talebi, Farhad
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (08) : 1158 - 1173
  • [24] Exergy analysis of a naturally ventilated Building Integrated Photovoltaic/Thermal (BIPV/T) system
    Agathokleous, Rafaela A.
    Kalogirou, Soteris A.
    Karellas, Sotirios
    RENEWABLE ENERGY, 2018, 128 : 541 - 552
  • [25] Effect of inlet and outlet angles on the flow performance of the ferrofluidic magnetic micropump
    Shaker, Sufian
    Hajjawi, Muhanad
    Khan, Altaf
    Kilani, Mohammad
    COGENT ENGINEERING, 2023, 10 (01):
  • [26] Effect of ventilation opening levels on thermal comfort status of both animal and husbandman in a naturally ventilated rabbit occupied building
    Ogunjimi, L. A. O.
    Osunade, J. A.
    Alabi, F. S.
    INTERNATIONAL AGROPHYSICS, 2007, 21 (03) : 261 - 267
  • [27] Thermal performance of a naturally ventilated building using a combined algorithm of probabilistic occupant behaviour and deterministic heat and mass balance models
    Yun, Geun Young
    Tuohy, Paul
    Steemers, Koen
    ENERGY AND BUILDINGS, 2009, 41 (05) : 489 - 499
  • [28] Field thermal performance of naturally ventilated solar roof with PCM heat sink
    Kosny, Jan
    Biswas, Kaushik
    Miller, William
    Kriner, Scott
    SOLAR ENERGY, 2012, 86 (09) : 2504 - 2514
  • [29] Parametric and performance analysis of a naturally ventilated floriculture greenhouse using a thermal model
    Ganguly, Aritra
    Bauri, Biplab
    10TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2013), 2014, 90 : 485 - 490
  • [30] Assessing the ventilation performance of a naturally ventilated livestock building with different eave opening conditions
    Norton, Tomas
    Grant, Jim
    Fallon, Richard
    Sun, Da-Wen
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2010, 71 (01) : 7 - 21