Comparison of different immunoassays and GC-MS screening of benzodiazepines in urine

被引:21
|
作者
Augsburger, M [1 ]
Rivier, L [1 ]
Mangin, P [1 ]
机构
[1] Univ Lausanne, Inst Med Legale, CH-1005 Lausanne, Switzerland
关键词
benzodiazepines; screening; radioimmunoassays; KIMS; GC-MS;
D O I
10.1016/S0731-7085(98)00266-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A total of 53 urine samples were tested by different immunoassay methods and by gas chromatography/mass spectrometry to determine repeatability of the different methods and to assess whether the immunoassays performed on samples obtained from elderly patients of the emergency section could be considered as reliable enough for identifying a benzodiazepine consumption. Repeatability was excellent for GC/MS and good for immunoassays. The specificity was not different for the three immunoassays (96%). The sensitivity varied from 36, 64 to 75% for Online, RIA Immunalysis and RIA DPC, respectively. An other difference between immunoassays and GC/MS was the ability of GC/MS to detect lorazepam and low concentrations of benzodiazepines whereas immunoassays did not. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 50 条
  • [1] The online screening technique for urinary benzodiazepines: Comparison with EMIT, FPIA, and GC-MS
    Beck, O
    Lin, Z
    Brodin, K
    Borg, S
    Hjemdahl, P
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (07) : 554 - 557
  • [2] Comparison of enzymatic and GC-MS/MS analysis of creatinine in urine samples
    Ferenczy, Viktoria
    Kotora, Peter
    Hudecova, Dusana
    Blasko, Jaroslav
    Kubinec, Robert
    Behulova, Darina
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 7 - 11
  • [3] Identification of urinary benzodiazepines and their metabolites: Comparison of automated HPLC and GC-MS after immunoassay screening of clinical specimens
    Valentine, JL
    Middleton, R
    Sparks, C
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (06) : 416 - 424
  • [4] Comparison of three immunoassays and one GC-MS method for the determination of valproic acid
    Cooreman, S.
    Cuypers, E.
    De Doncker, M.
    Van Hee, P.
    Uyttenbroeck, W.
    Neels, H.
    [J]. IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2008, 23 (04): : 240 - 244
  • [5] Screening and confirmatory GC-MS methods for the detection of trenbolone in bovine urine
    Wozniak, Barbara
    Matraszek-Zuchowska, Iwona
    Semeniuk, Stanislaw
    Klopot, Alicja
    Zmudzki, Jan
    [J]. BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2013, 57 (04) : 559 - 566
  • [6] Comparison of different SPME fibers for the GC-MS analysis of trace organics in a biological matrix (urine).
    Eggert, MS
    Brown, PA
    Evola, MG
    Goodwin, TE
    Rasmussen, LEL
    Schulte, BA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U385 - U385
  • [7] Toxicological screening after the REMEDI™ -: Comparison of a GC-MS screening with the REMEDI™
    Zgraggen, Sandra
    Bonatim, Rosa
    Gutteck-Amsler, Ursula
    Rentsch, Katharina M.
    [J]. THERAPEUTIC DRUG MONITORING, 2007, 29 (04) : 492 - 492
  • [8] Screening of clostebol and its metabolites in bovine urine with ELISA and comparison with GC-MS results in an interlaboratory study
    Crabbe, P
    Meyer, UJ
    Zhi, ZL
    Pieraccini, G
    O'Keeffe, M
    Van Peteghem, C
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2003, 27 (04) : 213 - 220
  • [9] Comparison of HPLC and GC-MS for measurement of cocaine and metabolites in human urine
    Phillips, DL
    Tebbett, IR
    Bertholf, RL
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (05) : 305 - 308
  • [10] Determination of galactose and galactitol in urine by GC-MS/MS
    Hudecova, Dusana
    Kotora, Peter
    Ferenczy, Viktoria
    Kubinec, Robert
    Behulova, Darina
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 29 - 33