Measurements of alpha radioactivity in arsenic contaminated tubewell drinking water using CR-39 detector

被引:10
|
作者
Ghosh, D [1 ]
Deb, A
Patra, KK
机构
[1] Jadavpur Univ, Nucl & Particle Phys Res Ctr, Kolkata 700032, W Bengal, India
[2] Jadavpur Univ, Sch Archaeol Dating, Kolkata 700032, W Bengal, India
关键词
radioactivity; arsenic-contaminated drinking water; CR-39;
D O I
10.1016/j.radmeas.2003.08.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Studies on the presence of alpha emitting nuclides in the environment assume importance since they are found to be carcinogenic. This paper presents the first ever report of the measurements of alpha activity in drinking water in different places of South and North 24 Parganas of West Bengal where arsenic contamination is severe. The study has been made with solid state nuclear track detector which is one of the most commonly used detectors in the studies involving nuclear radiation. Our analysis provides positive evidence of presence of high alpha activity in drinking water of South and North 24 Parganas. (C) 2003 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:19 / 22
页数:4
相关论文
共 50 条
  • [21] ALPHA-PARTICLE RADIOGRAPHY WITH THE CR-39 NUCLEAR TRACK DETECTOR
    DESOUZA, BA
    CABRAL, SC
    LOPES, RT
    RADIATION MEASUREMENTS, 1995, 24 (02) : 187 - 192
  • [22] FAST-NEUTRON SPECTROMETRY USING THE TRIPLE-ALPHA REACTION IN THE CR-39 DETECTOR
    ALNAJJAR, SAR
    ABDELNABY, A
    DURRANI, SA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 611 - 615
  • [23] Concentrations of alpha emitters in foodstuffs manufactured in the Bashiqa Region in Iraq using CR-39 detector
    Malik Hussien Kheder
    Hanaa Nafi Azeez
    Yasir Yahya Kassim
    Rajaa Abdullah Basheer
    The European Physical Journal Plus, 140 (2)
  • [24] Detection efficiency of alpha particles using CR-39 nuclear detector- etched with BSW
    Abdalla, Ayman M.
    Al-Naggar, Tayseer I.
    Alhandhal, Rayah H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 515 : 61 - 68
  • [25] Charged particle identification using CR-39(DOP) detector
    Yadav, J.S.
    Radiation Measurements, 1995, 24 (02):
  • [26] Alpha particle spectroscopy for CR-39 detector utilizing matrix of energy equations
    Awad, E. M.
    Soliman, A. A.
    Rammah, Y. S.
    PHYSICS LETTERS A, 2007, 369 (5-6) : 359 - 366
  • [27] Distribution of alpha particle tracks on CR-39 detector in radon diffusion chamber
    Stajic, J. M.
    Markovic, V. M.
    Milenkovic, B.
    Stevanovic, N.
    Nikezic, D.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 181
  • [28] FACTORS AFFECTING ETCHING PROPERTIES OF CR-39 DETECTOR FOR ALPHA-PARTICLES
    ISHIGURE, N
    MATSUOKA, O
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1988, 25 (04) : 404 - 409
  • [29] Characterization of saturation of CR-39 detector at high alpha-particle fluence
    El Ghazaly, M.
    Hassan, Nabil M.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (03) : 432 - 438
  • [30] Geometrical parameters of tracks registered by collimated alpha particles on CR-39 detector
    Joshirao, Pranav M.
    Shin, Jae Won
    Kim, Do Yoon
    Hong, Seung-Woo
    Kolekar, Rajesh V.
    Manchanda, Vijay Kumar
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 351 : 56 - 60