Improved method for the evaluation of shielding effect of objects near medium voltage transmission lines

被引:0
|
作者
Kiss, Istvan [1 ]
Nemeth, Balint [1 ]
Horvath, Tibor [1 ]
Berta, Istvan [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Elect Power Engn, Budapest, Hungary
关键词
Probability Modulated Attraction volume Method; lightning severity; substations; transmission lines; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There are several cases when medium voltage lines are running near each other and/or are crossing a high voltage line near a substation. Determination of the severity of lightning strokes at critical sections of the transmission lines is important from the point of a detailed risk calculation. There are different methods used nowadays for that purpose, but most of them are strongly simplified (usually 2D models) and the reliability of their results is limited. Probability Modulated Attraction Volume Method provides a more detailed and accurate analysis possible. Analysis of real 3D arrangements is presented in this paper.
引用
收藏
页码:1780 / 1785
页数:6
相关论文
共 50 条
  • [21] Detection of Power Devices and Abnormal Objects in Transmission Lines Based on Improved CenterNet
    Li L.
    Chen P.
    Zhang Y.
    Mei B.
    Gong P.
    Yu H.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (11): : 4757 - 4768
  • [22] LIGHTNING STROKES TO POWER TRANSMISSION LINES AND SHIELDING EFFECT OF GROUND WIRES
    BRAUNSTE.A
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (08): : 1900 - &
  • [23] Fault location in medium and high voltage transmission lines through efficient coding
    de Sousa, M. B.
    Barros, Allan K.
    Pessanha, J. E.
    2005/2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2006, : 893 - +
  • [24] An improved method for pylon extraction and vegetation encroachment analysis in high voltage transmission lines using LiDAR data
    Munir, Nosheen
    Awrangjeb, Mohammad
    Stantic, Bela
    2020 DIGITAL IMAGE COMPUTING: TECHNIQUES AND APPLICATIONS (DICTA), 2020,
  • [25] Improved electrogeometric model for shielding failure evaluation of double-circuit UHVAC transmission lines based on leader propagation simulations
    Ma, Ziwei
    Jasni, Jasronita
    Kadir, Mohd Zainal Abidin Ab
    Azis, Norhafiz
    Ma, Yanhua
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 239
  • [26] Analysis on Lightning Current and Position During Shielding Failure of High Voltage AC Transmission Lines
    Gu, Shan-qiang
    Yu, Zhan-qing
    Zhou, Xuan
    Wang, Ze-zhong
    Zhu, Tong
    Yan, Bi-wu
    He, Jin-liang
    Zeng, Rong
    Zhuang, Chi-jie
    INTERNATIONAL CONFERENCE ON SIMULATION, MODELLING AND MATHEMATICAL STATISTICS (SMMS 2015), 2015, : 139 - 146
  • [27] Three-dimensional analysis method of shielding failure characteristics of transmission lines
    Wu, Guangning
    Xiong, Wanliang
    Cao, Xiaobin
    Li, Ruifang
    Zhu, Jun
    Wu, G. (gnwu@home.swjtu.edu.cn), 2013, Science Press (39): : 374 - 382
  • [28] Theoretical and experimental study of EM fields and shielding effectiveness due to high voltage transmission lines
    Seker, SS
    Can, F
    Cerezci, O
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3993 - 3996
  • [29] The Effect of Cloud-to-Cloud Lightning on Medium Voltage Lines
    van Schalkwyk, Willem Dirkse
    Gomes, Chandima
    van Coller, John
    2022 36TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2022), 2022, : 14 - 19
  • [30] STATISTICAL EVALUATION METHOD OF THE INFLUENCE OF INSULATOR ASSEMBLIES ON THE RADIO INTERFERENCE LEVEL OF HIGH VOLTAGE TRANSMISSION LINES
    Couquelet, F.M.
    Riviere, D.
    Parraud, R.
    1978,