Improved method for the evaluation of shielding effect of objects near medium voltage transmission lines

被引:0
|
作者
Kiss, Istvan [1 ]
Nemeth, Balint [1 ]
Horvath, Tibor [1 ]
Berta, Istvan [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Elect Power Engn, Budapest, Hungary
关键词
Probability Modulated Attraction volume Method; lightning severity; substations; transmission lines; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There are several cases when medium voltage lines are running near each other and/or are crossing a high voltage line near a substation. Determination of the severity of lightning strokes at critical sections of the transmission lines is important from the point of a detailed risk calculation. There are different methods used nowadays for that purpose, but most of them are strongly simplified (usually 2D models) and the reliability of their results is limited. Probability Modulated Attraction Volume Method provides a more detailed and accurate analysis possible. Analysis of real 3D arrangements is presented in this paper.
引用
收藏
页码:1780 / 1785
页数:6
相关论文
共 50 条
  • [1] Analysis of the Shielding Effect of Distribution Lines on Electric Field Intensity Near UHVAC Transmission Lines
    Li, Haiqiong
    Zhang, Jiangong
    Wang, Yanzhao
    Gan, Zheyuan
    Xu, Jilai
    Fan, Yutong
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 305 - 309
  • [2] IMPROVED METHOD FOR DIGITAL PROTECTION OF HIGH-VOLTAGE TRANSMISSION-LINES
    RANJBAR, AM
    CORY, BJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (02): : 544 - 550
  • [3] Optimization of the Tie Lines in Medium Voltage Distribution Network Based on Improved Hungary Method
    Zhao, Hang-yu
    Zhao, Hong-shan
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 442 - 447
  • [4] Lightning Shielding Analysis of EHV and UHV AC Transmission Lines: the Effect of Operating Voltage and Terrain Topography
    Cuaran, Jose
    Acosta, Jbair
    Becerra, Marley
    Roman, Francisco
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1756 - 1760
  • [5] Lightning shielding failure analysis of UHVAC transmission lines with an improved EGM
    Yuan, Haiyan
    Fu, Zhengcal
    Wei, Bengang
    Du, Yaping
    HKIE Transactions Hong Kong Institution of Engineers, 2009, 16 (03): : 42 - 47
  • [6] Modeling and evaluation of shielding failure for multi-circuit transmission lines in different voltage levels on the same tower
    Liao, Minchuan
    Wang, Jingyi
    Li, Zhitai
    Pan, Chunping
    Dianwang Jishu/Power System Technology, 2013, 37 (09): : 2547 - 2552
  • [7] Shielding Effect of HVAC Transmission Lines on the Ion-Flow Field of HVDC Transmission Lines
    Zhou, Xiangxian
    Cui, Xiang
    Lu, Tiebing
    Liu, Yang
    Li, Xuebao
    He, Jiamei
    Bai, Ru
    Zhen, Yongzan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 1094 - 1102
  • [8] A Novel Method to Locate a Fault of Transmission Lines by Shielding Failure
    Yao, Chenguo
    Wu, Hao
    Long, Yi
    Mi, Yan
    Ma, Yi
    Shen, Yuan
    Wang, Lei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1573 - 1583
  • [9] High Voltage Transmission Line Protection Using Shielding Method
    Tun, Zar Ni
    Naing, Tun
    2009 INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING, PROCEEDINGS, 2009, : 363 - +
  • [10] Effects of Impulse Voltage Waveforms on Lightning Shielding Simulation Test of Transmission Lines
    Wang, Yu
    Wen, Xishan
    Lan, Lei
    Ye, Wanqi
    Li, Jutian
    Wang, Jingqian
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3515 - 3518