The performance of an evacuated tube solar hot water system in a domestic house throughout a year in a northern maritime climate (Dublin)

被引:20
|
作者
Gill, Laurence [1 ]
Mac Mahon, Joanne [1 ]
Ryan, Kevin [1 ]
机构
[1] Univ Dublin, Dept Civil Struct & Environm Engn, Trinity Coll, Dublin, Ireland
关键词
Evacuated tube; Solar water heater; Domestic hot water; THERMAL PERFORMANCE; FLAT-PLATE; TEMPERATE CLIMATE; HEATING SYSTEM; COLLECTORS; ENERGY; HEATERS; CONSUMPTION; RESOLUTION;
D O I
10.1016/j.solener.2016.07.052
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of an evacuated tube solar hot water system, installed on a domestic house (occupied by 2 adults and 3 children) in Dublin, Ireland has been intensely monitored over the period of a year. Instrumentation to measure flows and temperature were installed throughout both the solar circuit and domestic hot water system, in addition to solar radiometers being installed, on site to measure both global and diffuse radiation. The overall annual solar system efficiency at the installation angle of 29 to the horizontal was 63%. Heat losses from all aspects of the solar circuit and hot water system have also been quantified. The ongoing hot water usage pattern of the house occupants over the course of the year has been analysed as well as the changing attitudes to the use of hot water since the installation of the new solar system. This has shown some evidence that more hot water tends to be used on days where there has been more direct sunlight. Net present value calculations based on 5 years of operation however, have shown that the retrofit of such a system is not currently economically viable, although it has produced a carbon saving of approximately 1.1 tonnes CO2eq over its first 5 years of operation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 272
页数:12
相关论文
共 50 条
  • [31] Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions
    Maraj, Altin
    Londo, Andonaq
    Gebremedhin, Alemayehu
    Firat, Coskun
    RENEWABLE ENERGY, 2019, 140 : 874 - 883
  • [32] AN EXPERIMENTAL OPTIMIZATION STUDY OF A PHOTOVOLTAIC SOLAR PUMPING SYSTEM USED FOR SOLAR DOMESTIC HOT WATER SYSTEM UNDER IRAQI CLIMATE
    Mahdi, Mahmoud Maustafa
    Jaddoa, Ameer Abed
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (02): : 162 - 173
  • [33] PERFORMANCE EVALUATION OF AN AIR-TO-WATER HEAT PUMP SYSTEM IN DOMESTIC HOT WATER OPERATION FOR A PASSIVE HOUSE
    Sebarchievici, Calin
    Sarbu, Ioan
    ENERGY AND CLEAN TECHNOLOGIES CONFERENCE PROCEEDINGS, SGEM 2016, VOL I, 2016, : 519 - 524
  • [34] Water-to-water heat pump integration in a solar seasonal storage system for space heating and domestic hot water production of a single-family house in a cold climate
    Pinamonti, Maria
    Beausoleil-Morrison, Ian
    Prada, Alessandro
    Baggio, Paolo
    SOLAR ENERGY, 2021, 213 (213) : 300 - 311
  • [35] Detailed comparison of the performance of flat-plate and vacuum tube solar collectors for domestic hot water heating
    Yohanis, Y. G.
    Popel, O. S.
    Frid, S. E.
    Kolomiets, Yu. G.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2012, 31 (05) : 347 - 364
  • [36] EVACUATED GLASS TUBE SOLAR COLLECTOR AND ITS APPLICATION TO A SOLAR COOLING, HEATING AND HOT WATER-SUPPLY SYSTEM FOR THE HOSPITAL IN KINKI-UNIVERSITY
    HINOTANI, K
    KANATANI, K
    OSUMI, M
    SOLAR ENERGY, 1979, 22 (06) : 535 - 545
  • [37] PERFORMANCE EVALUATION OF AN INDIRECT SOLAR ASSISTED HEAT PUMP SYSTEM FOR DOMESTIC HOT WATER PRODUCTION
    Li, L.
    Ge, Y. T.
    Zavareh, M. T.
    3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 563 - 570
  • [38] Test method for evaluating and predicting thermal performance of thermosyphon solar domestic hot water system
    Kong, Weiqiang
    Wang, Zhifeng
    Li, Xing
    Yuan, Guofeng
    Fan, Jianhua
    Perers, Bengt
    Furbo, Simon
    APPLIED THERMAL ENGINEERING, 2019, 146 : 12 - 20
  • [39] Simulation and performance analysis of a solar domestic hot water system controlled by weather forecast information
    Colle, Sergio
    Koller, Thomas
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2496 - +
  • [40] Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate
    Ayompe, L. M.
    Duffy, A.
    Mc Keever, M.
    Conlon, M.
    McCormack, S. J.
    ENERGY, 2011, 36 (05) : 3370 - 3378